background image

SOLEO

® 

CL

 

SB-PF-SOL-004C

15:15 Water:+28.4°C  

Filtration  : ON 

   Chlorine : 1.31mg/L

Air:+27.9°C  pH: 7.3 

SOLEO

®

 CHLORINE

F I LT R AT I O N ,   P H   &   O R P  

VALID

ESC

PENTAIR WATER SOLUTIONS      SB-CU-IMP-056C  

(Rev. 03/2019)

EN

IMPORTANT SAFETY INSTRUCTIONS,
READ AND FOLLOW ALL OF THE INSTRUCTIONS,
KEEP THESE INSTRUCTIONS

INSTALLATION AND USER GUIDE 

Summary of Contents for SOLEO CL

Page 1: ...Chlorine 1 31mg L Air 27 9 C pH 7 3 SOLEO CHLORINE FILTR ATION PH ORP VALID ESC PENTAIR WATER SOLUTIONS SB CU IMP 056C Rev 03 2019 EN IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL OF THE INSTRUCT...

Page 2: ...2019 Pentair International LLC All rights reserved The document is subject to change without notice Trademarks and disclaimers Soleo and Pentair are trademarks and or registered trademarks of Pentair...

Page 3: ...ensors Connecting the probes Calibration of the chlorine probe and general points on chlorine Filtration connections and settings Filtration Expert menu Assisted backwash Support for filter backwash C...

Page 4: ...r conductors except if the conductors are also protected by a differential interrupter Refer to valid local codes for more details WARNING This product must be installed by an authorised or certified...

Page 5: ...m causing incorrect water chemistry which could harm people or equipment WARNING Consult the device display daily to ensure there are no alarm messages DANGER Water temperatures greater than 37 7 C 10...

Page 6: ...characters Soft cover Insulator of acidic vapours and humidity Connector cover Removable with a flat screwdriver FRONT VIEW The 2 cable glands are compatible with 1 2 threading for assembly on a bypas...

Page 7: ...he technical room The instant pool information free chlorine level water level pH RedOx as options The functioning durations of the filtration and disinfection from the current day since midnight and...

Page 8: ...holders intended for clamp saddles ensuring quick installation Installation organisation The hydraulic network must be linked to the earth to prevent the precision of the probes being altered The flo...

Page 9: ...ow switch SOLEO CHLORINE FILTR ATION PH ORP VALID ESC 28 04 2017 15 23 48 Water temp 29 0 C pH 7 8 ORP 607mV Cond 5264uS 3 28 g l SOLEO CHLORINE FILTR ATION PH ORP VALID ESC 28 04 2017 15 23 48 Water...

Page 10: ...ng three screws 4 to 5 mm diameter in appropriate plugs for the type of support and fix the device vertically on a clean support which is able to bear a minimum vertical load of 5 kg The 3 position sw...

Page 11: ...ts power supply needs to be protected by 16A 30 mA differential protection This protection must be cut before any intervention on the device Overvoltage category II 2 500 V peak electrical device If n...

Page 12: ...emperature is still below the designated threshold Water and air temperature probes INSTALLATION OF THE AIR TEMPERATURE PROBE OPTION If the air temperature probe is connected it automatically becomes...

Page 13: ...ctor 1 Completely unscrew the strain relief bushing be careful and do not let the black flexible seal fall 2 Pass the 3 cables through the screw and strain relief bushing 3 Connect each pod according...

Page 14: ...ine Chlorine CALIBRATION Please wait Chlorine CALIBRATION Please wait Enter the value read during the DPD1 test The pH ACTIVE CHLORINE RESERVE CHLORINE COMBINED CHLORINE TOTAL CHLORINE FREE The chlori...

Page 15: ...chosen timeframe from start to finish Shock The Shock function triggers 24 hours of forced filtration and electrolysis This function can be useful after the pool has been used by many visitors and wh...

Page 16: ...erature the filtration runs 24 7 to prevent the pool from freezing active wintering If the air temperature probe is connected this will be the reference value for managing the freeze protection Place...

Page 17: ...the 6 way valve in the Filtration and then hold it down VALID The procedure is finished Put the 6 way valve in the Rinsing position and then hold it down VALID SOLEO starts the filtration pump for th...

Page 18: ...e oxidation reduction potential indicates the oxidiser quality present in the water It is the result of the disinfectant quantity pollution quantity ratio 16 03 Water 26 3 C Filtration ON RedOx 261mV...

Page 19: ...er 6 In the Disinfectant Stop threshold sub menu modify the temperature limit below which the pump will no longer function which is 16 C by default 7 In the Disinfectant Injection sub menu modify the...

Page 20: ...AUTO so that the dosing pump supplies the pH corrector until the set value is reached OFF completely stops the pH control 3 In the pH Set Point sub menu select the value required see the bottom of th...

Page 21: ...tes that SOLEO CL is connected to a SPEEDEO Radio menu radio pairing between SOLEO CL and SPEEDEO Calibration menu pH probe This menu can only be accessed at SOLEO The default radio channel is Channel...

Page 22: ...UAGE FRENCH LANGUAGE FRENCH Welcome menu Time setting menu Hour 16 h Minute 03 min Hour 16 h Minute 03 min Hour 16 h Minute 03 min DAY 1 HISTORY Filtration 15H24m22s Disinfect 06H53m37s pH control 01H...

Page 23: ...PEROXIDE probe mode Type PUMP ELECTROLYSIS PEROXIDE WEEK DAY Stop threshold 16 C Injection 15 sec every 15 m PUMP mode type Pool Pool 48M3 PEROXIDE mode type Dos pump 1 0 L h PEROXIDE mode type Vol w...

Page 24: ...Cl coef 0 5 Cl probe calibration coef 1 0 ideal Current 10 mA current of the Cl probe 4 mA 0 mg L 20 mA 10 mg L Languages LANGUAGE FRANCAIS ENGLISH Update Firmware update insert the USB stick and hol...

Page 25: ...the cage by hand For at least 10 minutes dip the end of the probe into white vinegar Depending on the probe environment organisms may grow and disrupt the measurement It then becomes necessary to phys...

Page 26: ...he bottom under Information read the version no X X and check that it has changed 5 3 Replace the orange safety cover 5 4 Replace the soft cover 2 1 Remove the soft cover then remove the orange cover...

Page 27: ...rritate the skin of the bathers The pH is so high that it cancels out the disinfectant effect of the chlorine Despite the excess dose of chlorine the water is just disinfected but by contrast it is sa...

Page 28: ...1004 LAUSANNE Switzerland Copyright Limited Licence except as specifically permitted herein no portion of the content of this document may be reproduced in any form or by any means without the prior...

Reviews: