Pentair Pro Elite
268-762-100-1044 Demand Operation Manual Download Page 24

Placing 268 Water Conditioning System 

Into Operation (Fill Brine Tank Last)

Quick Cycling the Demand Control

It is required that the control be quick cycled to specific 

regeneration cycles when placing the conditioner into 
operation. Please review the following instructions for 
quick cycling the control before proceeding to startup.
1.  With the control in the treated water position, press 

and hold the REGEN button on the control for five 

seconds. This will initiate a manual regeneration. 
The control will display an hourglass indicating that 
the motor and camshaft are turning. The control 
also displays the total regeneration time remaining. 
When the control reaches the backwash cycle, the 
hourglass is no longer displayed and the motor will 
turn off. Pressing the SET button will display the time 
remaining for the current cycle.

2.  Press and release the UP and SET buttons to move 

the control to the next cycle. 

Note: 

The control can be sent directly back to the 

treated water position from any regeneration cycle. 

Press the UP and SET buttons (about five seconds) until 

the hourglass icon appears solid. The control will now 
skip all remaining regeneration cycles.  

Startup

After you have programmed the control, the conditioner 
will need to be placed into operation. Follow these steps 
carefully, as they differ from previous Pro Elite valve 
instructions.
1.  Remove the cover from the valve. Removing the cover 

will allow you to see that the camshaft is turning, and 
in which cycle the camshaft is currently positioned.

2.  With the supply water for the system still turned 

off, position the bypass valve to the “not in bypass” 

(normal operation) position.

3.  Press and hold the REGEN button on the Demand 

control for five seconds. This will initiate a manual 

regeneration. The control will display an hourglass, 
indicating that the motor and camshaft are turning to 
the backwash cycle (C1). The control also displays the 
total regeneration time remaining. When the control 
reaches the backwash cycle, the hourglass is no 
longer displayed and the motor will turn off. Pressing 
the SET button will display the time remaining for the 
current cycle. 

4.  Fill the media tank with water.

A.  While the Demand control is in cycle 

(Backwash), open the water supply valve very 
slowly to approximately the 1/4 open position. 
Water will begin to enter the media tank. Air 
will begin to be purged to drain as the media 

tank fills with water.

 

WARNING: 

If the supply valve is opened 

too rapidly or too far, media may be 
lost out of the tank into the valve or the 
plumbing. In the 1/4 open position, you 
should hear air slowly escaping from the 
valve drain line.

B.  When all of the air has been purged from the 

media tank (water begins to flow steadily from 

the drain line), open the main supply valve all 
of the way. This will purge the remaining air 
from  
the tank.

C.  Allow water to run to drain until the water 

runs clear from the drain line. This purges any 
debris from the media bed.

5. 

Add water to the regenerant tank.

A.  With a bucket or hose, add approximately 4 

gallons (15 liters) of water to the regenerant 

tank. 
If the tank has a salt platform in the bottom 
of the tank, add water until the water level 

is approximately 1 inch (25 mm) above the 

platform.

Note: 

It’s recommended that you do not put regenerant 

into the tank until after the control valve has been put 
into operation. With no regenerant in the tank, it is 

much easier to view water flow and motion in the tank.  

6.  Prime the regenerant line.

A.  Slowly open the main water supply valve again 

to the fully open position. Be sure not to open 
too rapidly, as that would push the media out 
of the media tank.

B.  Quick cycle the control to the regenerant tank 

Refill position (C8). 

Note: 

As you advance through each cycle, there will be 

a slight delay before you can advance to the next cycle. 
There will be a pause after the regenerant draw and 
slow rinse cycles. This cycle (C4) is a repressurization 
cycle and is designed to allow the water pressure to 
equalize on each side of the valve discs. Allow the 
control to repressurize (three minutes) before cycling 

the control to the regenerant tank refill position. 

24 • 

PENTAIR 

Pro Elite Professional Series Pro Elite Demand Instruction Manual

Summary of Contents for Pro Elite 268-762-100-1044 Demand

Page 1: ...PRO ELITE PROFESSIONAL SERIES PRO ELITE DEMAND WATER TREATMENT SYSTEM OPERATION MANUAL...

Page 2: ...ors 17 Button Functions 17 Programming Overview 18 Demand Control Operation 18 Level I Programming 18 Level l Programming Demand Conditioner 19 Level II Programming P Values 21 Level I Programming P V...

Page 3: ...mplies with specific performance specifications intended to minimize the amount of regenerant brine and water used in its operation Efficiency rated water softeners shall have a rated salt efficiency...

Page 4: ...tions that do not use an O ring seal Do not use pipe dope type sealants on the valve body Do not use pliers or pipe wrenches Do not use petroleum based lubricants such as petroleum jelly oils or hydro...

Page 5: ...orage 240 lbs 109 kg 240 lbs 109 kg 240 lbs 109 kg Drain Water Rate 2 7 gpm 10 2 L m 3 9 gpm 14 7 L m 3 9 gpm 14 7 L m Service Connection Size 1 NPT 1 NPT 1 NPT Drain Connection Size 3 4 NPT 3 4 NPT 3...

Page 6: ...itioner be installed in a protected environment When installing the water conditioning system outdoors several items must be considered Moisture The valve and control are rated for NEMA 3 locations Fa...

Page 7: ...tch Mechanism 4 Base 11 Tank Collar 5 268 Logix PE Valve w 762 Control 12 Riser Tube 6 Resin Tank 13 Upper Basket 7 Shield Brine Tank 1 2 3 4 5 6 7 1 Cover 5 Brine Tube Assembly 2 Collar Tank 6 Foot L...

Page 8: ...Dimensions 36 9 938 1 60 7 1541 6 19 8 503 8 16 8 427 1 17 6 447 20 5 521 1 35 1 890 4 28 2 715 9 32 2 817 5 53 4 1356 6 55 1398 1 5 0 127 2 5 63 5 8 PENTAIR Pro Elite Professional Series Pro Elite De...

Page 9: ...Before Installation Cold water lines shown Soft Water Hard Water Outside Faucet Outside Faucet Bath Tub Lavatory Toilet Kitchen Laundry Tubs Pump or Meter Hot Water Outlet Water Heater Brine Tank Ove...

Page 10: ...and the salt tank up and in position Level as needed The tank has two ports that will be connected One to a drain and one to the valve 3 Place the brine tube in position inside the pocket at the botto...

Page 11: ...Model 1265 Bypass Included Water Conditioner Water Conditioner Water Conditioner Water Conditioner Normal Operation In Bypass Figure 6 Typical Three Valve Bypass Configuration Not provided by manufac...

Page 12: ...r wire the hose in place at the drain point Also provide an air gap of at least 1 1 2 inch between the end of the hose and the drain point 5 When the drain empties into an overhead sewer line a sink t...

Page 13: ...hose in place Drain Air Gap Figure 10 Electrical Connection Note There are no user serviceable parts in the AC adapter motor or the control board The Demand control operates on a 12 volt alternating c...

Page 14: ...heck closes Slow Rinse Downflow Cycle C3 Water flow moves the regenerant through the resin at a specific rate and rinses to the drain The resin is regenerated Repressurization Cycle C4 Pressure is bal...

Page 15: ...tely 90 degrees out of phase Note If electrical power is not available the camshaft can be rotated counterclockwise by hand if the motor is removed Cycle Indicators 0 Treated Water or brine make up if...

Page 16: ...Dosage Polystyrene resin 1 2 fluid ounce 35 5 mL per cubic foot Non resinous exchangers 0 8 fluid ounce 23 7 mL per cubic foot 2 Regenerant tank conditioners A Backwash the conditioner and add the re...

Page 17: ...cycle Appears as a solid icon during a cancelled regeneration and the control is cycling directly back to the home position 13 Indicates the selected program setting has been locked out Lock settings...

Page 18: ...the information in memory for 8 to 24 hours depending on the installation If the super capacitor is exhausted the Demand control will display four dashes immediately upon power up The Time of Day and...

Page 19: ...en regeneration 7 Salt Dosage Set to desired desired dosage lbs per cubic feet of resin Screen Buttons to Description Range Press Days 1 to 30 Lbs ft3 3 to 18 or press then or press press then or pres...

Page 20: ...in 2 00 AM Hr Min Range dependent on value selected for P10 Clock mode P4 Calendar Override 0 99 1 3 Days 0 No calendar override 0 5 Regeneration twice a day at time of regeneration and 12 hours later...

Page 21: ...te switch must be active to start regeneration on 742 time clock units P13 Chlorine Generator Options 0 2 1 0 0 No Chlorine Generator 1 Salt Check Only 2 Generate Chlorine P14 Refill Rate 1 700 1 1 gp...

Page 22: ...lue Note The control must be in the treated water position to change settings C Description Range Minimum Increments Default Setting Notes C1 Backwash 0 200 1 Min 10 Flow rate dictated by size of drai...

Page 23: ...for Thursday in gallons or m3 0 131 070 gallons or 0 1 310 70 m3 762 only H12 Average usage for Friday in gallons or m3 0 131 070 gallons or 0 1 310 70 m3 762 only H13 Average usage for Saturday in ga...

Page 24: ...lass is no longer displayed and the motor will turn off Pressing the SET button will display the time remaining for the current cycle 4 Fill the media tank with water A While the Demand control is in...

Page 25: ...ly 9 Finally turn on a faucet plumbed after the water conditioner Run the faucet until the water runs clear 10 Add the appropriate amount of regenerant to the regenerant tank The Water Conditioning Sy...

Page 26: ...eneration icon will be displayed The control will immediately begin a regeneration Delayed Second Regeneration Pressing and releasing the REGEN button while the control is in regeneration will program...

Page 27: ...Pro Elite Valve Exploded View and Parts List BYPASS BYPASS 20 21 22 23 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 11 12 PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual 27...

Page 28: ...585 Skirt Pro Elite Lt Gray 1 19 1232370 O Ring Riser Tube 1 8 1000813 Transformer 230 240 VAC 50 60 Hz 12 VAC British Plug 1 20 1040930 1265 Bypass Valve 1 9 3019221 Motor Optical Cable 1 21 Drain Li...

Page 29: ...4 2 3 4 5 6 7 9 10 12 13 14 15 16 17 11 Conditioner Tank and Regenerant Tank Assembly Exploded View and Parts List 1 A A A 25 8 19 5 25 29 PENTAIR Pro Elite Professional Series Pro Elite Demand Instru...

Page 30: ...e Torsion 2 9 4005393 Label Domed Button 1 4 Pentair Logo 1 22 4000359 Spring Torsion 2 10 4000347 Cover Brine Tank Pro Elite 1 23 4000358 Latch Cover Pro Elite 2 11 4000348 Collar Brine Tank Pro Elit...

Page 31: ...4 1 6 60068 8 06 Brine Float w One Grommet As Purchased 1 7 60002 27 Air Check Assembly 1 8 BR10332 Tubing Insert Brass 2 CH20774 Overflow Fitting Assembly 1 CH15031 1 Overflow Elbow 1 CH15031 2 Overf...

Page 32: ...isplay Check that motor is connected Verify that motor wire harness is connected to motor and control module Verify that optical sensor is connected and in place Verify that motor gear has engaged cam...

Page 33: ...c Clean injector and screen d Replace injector and cap Contact dealer e Remove foreign matter from disc and check disc for closing by pushing in on stem Replace if needed Contact dealer f Put control...

Page 34: ...34 PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual...

Page 35: ...PENTAIR Pro Elite Professional Series Pro Elite Demand Instruction Manual 35...

Page 36: ...4 tech support pentair com 2019 Pentair Residential Filtration LLC All rights reserved For a detailed list of where Pentair trademarks are registered please visit pentair com en registrations html Pen...

Reviews: