Level II Programming – P Values
Level II program parameters can be adjusted and used
to fine-tune the conditioner’s operation. The parameters
are accessible by pressing and holding the UP and DOWN
buttons until the control displays a “P” value. Note: The
control must be in the home position to change settings.
See Table below for Level ll parameters. Typically the
Level ll parameters will not need to be adjusted, as
the default settings accommodate most applications.
Contact your Water Treatment Professional before
attempting any programming.
P#
Description
Range
Minimum
Increments
Default
Units
Notes
P9
Units of Measure
0 - 1
1
(2)
0 = US 1 = Metric
P10
Clock Mode
0 - 3
1
(2)
0 = 12 Hr Clock, flow rate displayed
1 = 24 Hr Clock, flow rate displayed
2 = 12 Hr Clock, time of day displayed
3 = 24 Hr Clock, time of day displayed
P11
Service Interval
0 - 250
1
0
Months
Uses 30 days for each month.
P12
Remote switch
delay for
regeneration
3 - 250
1
60
Seconds
Time remote switch must be active to start
regeneration on 742 time clock units.
P13
Chlorine Generator
Options
0 - 2
1
0
0 = No Chlorine Generator
1 = Salt Check Only
2 = Generate Chlorine
P14
Refill Rate
1 - 700
1
(1)
gpm x 100
P15
Draw Rate
1 - 700
1
(1)
gpm x 100
P16
Reserve Type
0 - 3
1
0
0 = Variable reserve delayed regeneration
1 = Fixed reserve delayed regeneration
2 = Variable reserve immediate regeneration
3 = Fixed reserve immediate regeneration
P17
Initial average or
fixed reserve
0 - 70
1
30
% of
Capacity
Depends on value entered in P16.
P18
Flow sensor select
0 - 5
1
(1)
0 = Internal Magnum NHWB
1 = 1" Pro Elite turbine
2 = 2" Pro Elite turbine
3 = User define K-factor
4 = User define Pulse Equivalent
5 = Internal Magnum HWB
P19
K-factor or Pulse
Equivalent
1.0 -
99.99
0 - 9999
0.01
1
0.01
1
K-factor P18 = 3
Pulse Equivalent P18 = 4
P r
Refill First
0 - 1
1
0
0 = Refill first off
1 = Refill first on
P d
Remote switch
operation
0 - 1
1
0
0 = Immediate Regeneration
1 = Delayed Regeneration
Notes: (1) Default selected with valve type and resin volume.
(2) Factory Default is "0" for North America and "1" for World Units.
PENTAIR
Pro Elite Professional Series Pro Elite Demand Instruction Manual • 21