5
P1062 (06/06/19)
PENTAIR PENTEK
*
SOLAR DRIVE SPECIFICATIONS
Input Specification:
- Dual Solar PV Array Input
- Maximum Solar Open Circuit Voltage:
400 Vdcˆ
- Maximum Solar PV Current in Series:
9 Amps per solar arrayˆˆ
- Earth-ground connected to chassis
ˆDC PV input terminals shall only be connected to listed photovoltaic modules and panels that
comply with UL 1703.
ˆˆSuitable for use on a circuit capable of delivering not more than 27 rms symmetrical amperes,
400 volts maximum.
Output Specification:
- Maximum Output Current:
13 Arms (1-phase motors)
- Maximum Output Current:
10.5 Arms (3-phase motors)
- Maximum Power Sustained:
3500 W
Protections:
- Short-circuit, ground-fault, over-temperature, overload, over-voltage,
over-current, and solar input reverse polarity protection
- Automatic dry well protection and pump locked rotor protection
Integral solid state short circuit protection does not provide branch circuit protection. Branch
circuit protection must be provided in accordance with the National Electrical Code and any
additional local codes.
WARNING:
Carefully check the motor load specifications and solar PV array maximum power point
voltage to set up the system properly using this manual!
ELECTRICAL
MECHANICAL
Solar PV open circuit voltage:
400Vˆ
Degree of protection:
TYPE 3R
Max PV panel current in series:
9A
Enclosure material:
Aluminum
Max Single phase AC motor current:
13A
Operating temperature:
-40˚C to 40˚C
Max Three phase AC motor current:
10.5A
Dimensions:
18”x10”x5”
AC Source Terminals:
AWG #10-16
Solar Terminals:
AWG #10-16
Motor terminal:
AWG #8-16
Float Sensor terminals:
AWG #14-20
ˆPer solar array