4. If the spa blower is to be used for additional spa jet venturi, connect the
supply line into the air supply line of the spa jet using a tee, then follow the
instructions of 1 & 2 and refer to (diagram 4)
5. Spa blower MUST be mounted in a vertical position only, with the
discharge downwards (refer diagram 1, 2, & 4).
6. If a air switch or three speed option is being fitted a roll of air tube is
supplied, enclose the air line in conduit for mechanical protection, place one
end of the tube onto the nipple of the air button fitted on the spa pool, place
the other end of the air line onto the spa blower, the air nipple is located on
the under side of the spa blower.
7. Place the spa blower 10 amp lead into a 240 volt 50Hz designated power
point.
8. Minimal Air Hole Specifications
36 x 6 mm Diameter Holes
18 x 8 mm Diameter Holes
(refer diagram 5)
IMPORTANT INSTALLER PLEASE NOTE
The diameter and quantity of air holes listed above are based on a spa pool
air manifold maximum water submergence depth of:
(1) 600mm (seat/recliner manifold)
(2) 800mm (footwell manifold)
If the spa depth/manifold dimensions vary from above please contact the
Pentair Water office in your state for advice and verification, failure to
comply may damage the equipment and void the product warranty.
OPERATION OF YOUR SPA BLOWER
1. Switch power on, your spa blower will start.
(a) If your spa blower has been plugged into another controller it may not
start until the air button or some other form of switching has been pressed.
(Check with your installer).
(b) Air Switch Blower Operation
Simply press the air button located on the spa and your spa blower will
start on high speed, press your button again and this will turn the spa
blower off.
WARNING
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or
instruction concerning the use of the appliance by a person responsible for
their safety.
Children should be supervised to ensure they do not play with the
appliance.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
No part of this appliance is to be located above the spa pool and must be
inaccessible to a person in the spa pool. All parts must be fixed so they cannot
fall into the spa pool.
The appliance should be supplied through a residual current device (RCD) having
a rated current not exceeding 30mA.