background image

 ®

ONGA

1. Run 50mm PVC pipe line from the spa pool manifold outlet to spa blower position 
(maximum operating distance 12 metres), ensuring that the 50mm pipe line  has a 

minimum fall of 1:10 back to the spa, this will allow the pipe line to have minimum 
water lying in the pipe (refer diagram 1).

2. Run your vertical 50mm pvc pipe a minimum of 600mm above
the spa pools maximum water level.

       
Allow 24 hours for glue vapours to dissipate from the pipe work before 

mounting spa blower onto pipe (failure to do so may cause damage to the 
spa blower, pipe work and void warranty). Place the blower on the pipe and 
tighten the stain-less steel mounting screw located on the check-valve 

(refer diagram 1). 

DO NOT GLUE THE SPA BLOWER TO THE 50MM PIPE

.

SPA BLOWER INSTALLATION AND OPERATION  INSTRUCTIONS

3. If the spa blower is to be mounted below water level, extend the 
air loop 600mm above the maximum water level and return back to 

the spa blower, drill a bleed hole after loop to remove any 

condensation  (refer diagram 2). DO NOT create a water trap in the 
blower supply pipe (refer diagram 3), as the water lying in the pipe 
will create additional back pressure on the spa blower. Mount the 

spa blower as instructed above (2).

Diagram 1

Diagram 3

Diagram 2

Page 2

These instructions act as a guide only and do not cover every contingency.

People not familiar with pool filtration and pumping equipment should seek

advice from an authorised Onga stockist.

Summary of Contents for ONGA

Page 1: ...unfamiliar with the correct installation or operation of this type of equipment you should contact the distributor manufacturer for the correct advice before proceeding with the installation or operation of this product Installation operation instructions ONGA ...

Page 2: ...ain less steel mounting screw located on the check valve refer diagram 1 DO NOT GLUE THE SPA BLOWER TO THE 50MM PIPE SPA BLOWER INSTALLATION AND OPERATION INSTRUCTIONS 3 If the spa blower is to be mounted below water level extend the air loop 600mm above the maximum water level and return back to the spa blower drill a bleed hole after loop to remove any condensation refer diagram 2 DO NOT create ...

Page 3: ... for advice and verification failure to comply may damage the equipment and void the product warranty OPERATION OF YOUR SPA BLOWER 1 Switch power on your spa blower will start a If your spa blower has been plugged into another controller it may not start until the air button or some other form of switching has been pressed Check with your installer b Air Switch Blower Operation Simply press the ai...

Page 4: ...pulse of air that operates the micro switch inside the spa blower Check micro switch operation Push air button and a faint click should be heard at the spa blower if no click is heard check all connections if they are all OK and spa blower still doesn t start remove spa blower and take it to the nearest Pentair Water service agent Spa blower is making a grinding noise when operating Bearings brush...

Page 5: ...aken for errors omissions or changes in product specifications Pentair Water reserves the right to change specifications Head Office Pentair AU NZ 1 21 Monash Drive Dandenong South Vic 3175 Australia National Customer Service Phone 1300 137 344 Fax 1800 006 688 National Dealer Locator Phone 1800 664 266 Email au sales pentair com Web www pentair com au New Zealand National Customer Service Phone 0...