background image

figure 24: Typical mi identification tag  

(for use in hazardous areas)

 

–   mi unit reference

  is the order reference following the nomenclature 

of MI heating units (also see page 6)

–   heating Cable ref

. is the type of MI heating cable

–   element length

 is the heated length of the MI unit

–   Year of manufacture

 is the manufacturing year

–   Circuit length (if different)

 informs about the “total circuit length” in 

case of multiple elements being connected in series

–   Design Temperature Class

 states the “T-class” or “Auto Ignition 

Temperature” including the “Zone” classification, which the unit is 

designed for

–   Design method

 informs about the method of temperature control, 

which has been used for the design and must be installed to control 

the heating unit. 

 

examples: 

1) “Stabilized” indicates that the design method used is “stabilised 

design”. All parameters used in the design of the application must be 

respected in order to comply with the hazardous area requirements 

(e.g. pipe diameters, insulation thickness, process, ambient 

conditions ...). The reference temperature for the sheath temperature 

calculations is either the calculated “max. uncontrolled temperature” 

or the “max. process temperature”, whichever is higher.

2)  “Control limited” indicates that the design method used is 

“control limited design”. The reference temperature for the sheath 

temperature calculations is the control limited set point and must be 

assured by the use of an alarm capable control unit making sure the 

heating element is switched off, when the pipe/equipment exceed this 

temperature. The use of a wrong control device or a change of the 

temperature setting will invalidate the design calculation. 

3) “Limiter-Lockout” indicates that the design method used assumes 

the installation of an approved limiter (typically a safety temperature 

limiter which sensor is installed on the heating cable surface using 

an “artificial hotspot”). The set point of the limiter must be below the 

T-class of the area and may require an additional down-adjustment 

for potential falsifying of the measured temperature, refer to the 

instructions given by the manufacturer of the limiter. 

MI Unit Reference:

  

B/HSQ1M1000/43M/1187/230/2M/SC1H2.5/X/M20/EX

Heating Cable Ref.:  

HSQ1M1000 

Element Length:  

43 m

Year of Manufacture:   2006 

Circuit Length (if different):

Grade:  

  

  (high) 

Design Temperature Class:   T1   Zone1 

Design Method:    

Limiter-Lockout 

Maximum Withstand Temperature:  450°C

Max. Sheath Temperature:   331°C 

Sheath Reference Temperature:  200°C

Nom. Power Output @ 230 V:   1187 W @ Maintain Temperature

Order No:  

  

 

Customer Order No:

Batch number:    

XXXXXX 

Circuit Reference:

Type Examination No:       

Baseefa02ATEX0046X 

THIS TAG MUST NOT BE REMOVED

Follow installation and operating instructions for safe use in hazardous areas!

2 G     EEx e      T1

1180

29

Summary of Contents for Mi Series

Page 1: ...Mineral Insulated MI Series Heating Systems Installation Maintenance and Operation Manual Thermal management EN PyrotenaxMI IM DOC586 R4...

Page 2: ...eating cable installation 9 Components selection and installation 23 Temperature control and limitation 24 Thermal insulation and marking 27 Power supply and electrical protection 31 System testing 32...

Page 3: ...ating cable system dual conductor Junction box MI cold lead cable single conductor Circuit identification tag Hot cold joint MI cold lead cable dual conductor Hot cold joint Circuit identification tag...

Page 4: ...ase contact your Pentair Thermal Management representative Pentair Thermal Management offers two different cable constructions for electrical heat tracing purposes single conductor cables which are ty...

Page 5: ...installation inspection operation and maintenance must be in accordance with the standards IEC 60519 IEC 62086 EN 50019 and EN60079 7 where applicable Other local requirements and national electric co...

Page 6: ...formation must also be provided about the T rating and temperature data relevant to the application max sheath temperature data to enable the correct representation of data on hazardous area tags atta...

Page 7: ...ors 1 1 1 Maximum voltage U0 U 300 500 V Maximum withstand temp 1 Brazed heating unit 200 C 400 C 450 C Laser welded heating unit 700 C Temperatureclassification T6 T3 T6 T2 T6 T1 Minimum cable spacin...

Page 8: ...n aspects refer to our product datasheets or contact Pentair Thermal Management for assistance Check the design specification to make sure the correct heating cable is installed on each pipe or vessel...

Page 9: ...Check materials received Inspect heating cable and components for in transit damage Review the heating cable design and compare the list of designed materials to the catalogue numbers of heating cable...

Page 10: ...installed must be reasonably clean Remove dirt rust and scale with a wire brush and oil and grease films with a suitable solvent 3 2 Heating cable pulling and laying Heating cable pulling tips Figure...

Page 11: ...ions Do not bend the cable within 150 mm of the hot to cold junction or remote terminations When installing MI and other constant wattage heating cables ensure that they do not overlap or cross Doing...

Page 12: ...insulation thickness equivalent to the pipe insulation Please refer to the engineering documentation for project specific allowances 2 For pipes requiring more than one run of heating cable apply the...

Page 13: ...cable to move freely under its own weight Other attachments like aluminium tape or glass tape may be used if specified in the design documentation The heating cables may be installed in straight multi...

Page 14: ...s additional fixing devices as pre punched steel strips as shown below Figure 7 Typical cable layout on large surfaces like tank walls Figure 8 Fixing device pre punched metal strap Avoid sharp edges...

Page 15: ...ultiple runs of cable are applied e g HARD SPACER SS 25MM 25M Various types of metal meshes are available for installation on tanks valves pumps e g mesh types FT 19 and FT 20 3 5 Typical installation...

Page 16: ...wire can damage the heating cable surface over time use wire cloth band wherever possible Figure 11 Allowances for valves flanges and pipe supports Use tie wire or wire cloth band to hold cable to irr...

Page 17: ...spacing of heating cables Hot cold joint Tie wire wire cloth band 17 Stainless steel pipe straps banding or tie wire wire cloth band etc Drip loop Hot cold joint Cold lead Junction box 150 mm Insulati...

Page 18: ...for specific heating cable length needed MI heating cable Apply tie wire wire cloth band or other appropriate fixing material to hold MI heating cable in place Stainless steel pipe straps banding tie...

Page 19: ...el pipe straps banding tie wire or wire cloth band typical MI heating cable MI heating cable is applied to outside radius of elbow Flange Heating cable Apply tie wire or wire cloth band to hold heatin...

Page 20: ...clearly states other values also refer to page 11 figure 5 Figure 21 Dummy supports 20 Insulation Dummy leg Pipe shoe Heating cable Stainless steel pipe straps banding tie wire or wire cloth band Stai...

Page 21: ...tes other values also refer to page 11 figure 5 Cover the heating cable with metal foil or equivalent before applying insulation to ensure the cables do not become trapped in the insulation General no...

Page 22: ...t traced system that increase the surface area of the insulated pipe vessel or metallic fins that protrude out of the insulation e g supports will increase the overall heat loss These areas of increas...

Page 23: ...uch that power cable and heating cable entries point downwards to avoid water ingress in the insulation Confirm junction box glands and stopping plugs are appropriate for application and fixed firmly...

Page 24: ...cases where stabilized design is not applicable a con trol thermostat must ensure that the heating system under normal conditions will be switched off as soon as maintain temperature is reached An add...

Page 25: ...tripping of safety limiters The setpoint might need to be adjusted accordingly Contact Pentair Thermal Management or the supplier of the limitation device in order to obtain detailed information conc...

Page 26: ...of the fluid best location upstream in case of warmer inrushing fluid Impact of heat sinks such as supports etc best location away from heat sinks Accessability for maintenance purposes best location...

Page 27: ...e insulations materials to be used Contact your Pentair Thermal Management representative if you have any questions Check that all pipes including fittings wall penetrations and other areas are comple...

Page 28: ...les are mechanically protected and properly sealed at all places where they penetrate the insulation cladding Ensure that all places are sealed where thermostat capillaries sensor cables or support br...

Page 29: ...The reference temperature for the sheath temperature calculations is the control limited set point and must be assured by the use of an alarm capable control unit making sure the heating element is sw...

Page 30: ...y be significantly lower than during start up phase in particular for heating cables using conductors with a high temperature coefficient e g copper conductor Refer to the design information for prope...

Page 31: ...ion When design results in a higher leakage current a maximum 300mA RCD may be used All safety aspects need to be proven Also refer to local standards Special regard should be given to electrical safe...

Page 32: ...dic maintenance see Section 9 2 The heating circuit electrical resistance needs to be measured and compared to the design documentation before initial startup 8 2 Test method for insulation resistance...

Page 33: ...testing The system should be tested regularly Check in advance whether hazardous area conditions allow insulation testing A hot work permit might be required When measuring the insulation resistance f...

Page 34: ...oting WARNING Damage to cables or components can cause sustained electrical arcing or fire Do not energize heating cables that have been damaged Damaged heating cable or terminations must only be repa...

Page 35: ...nstaller Project Site name Area name Value Remarks Date Initials Heating circuit number P ID number Drawing number Panel Circuit breaker number Heating cable type Cable length m loop 2 x m star 3 x m...

Page 36: ...insulation works Insulation resistance test voltage V DC 1000 V DC Insulation resistance test before thermal insulation M 20 M Loop resistance ohms Average pipe temperature when measuring loop resist...

Page 37: ...n cladding yes Thermal insulation material and thickness meet designed values yes Warning labels installed on cladding every 5 m and at components yes Insulation resistance test voltage V DC 1000 V DC...

Page 38: ...eating cable is causing a direct short 6 Presence of moisture in terminations or connections 7 Damaged termination 8 Moisture in junction boxes B Symptom Circuit breaker trips Probable Causes 1 Circui...

Page 39: ...e pipe Replace damaged sections of heating cable 6 Dry out cold lead and or connections and replace termination if necessary 7 Replace termination 8 Check and replace seals on junction boxes Correctiv...

Page 40: ...robable Causes 1 No input voltage 2 Temperature controller wired in the normally open N O position 3 Limiter has tripped 4 Broken or damaged heating element hot cold joint end cap or broken tail 5 Wro...

Page 41: ...d entering pipe Corrective actions 1 Repair electrical supply lines and equipment 2 Confirm wiring using the normally closed N C terminals so that contacts close with falling temperature 3 Check the r...

Page 42: ...42...

Page 43: ...43...

Page 44: ...02 577 61 51 Fax 39 02 577 61 55 28 salesit pentair com Lietuva Latvija Eesti Tel 370 5 2136633 Fax 370 5 2330084 info baltic pentair com Magyarorsz g Tel 36 1 253 7617 Fax 36 1 253 7618 saleshu pent...

Reviews: