MAESTRO
®
C
O
N
T
R
O
L
VALID
ESC
BUS
24 V
RS-485
A1
A2
ON?
13
MAESTRO is connected
to a classic electrical
installation.
All of the outlets are
dry contacts which
are normally open
(NO) and can interrupt
up to 230 V-10 A
(above this, add a
contactor).
The 3-position interrupters
are kept.
The filtration interrupter
makes it possible to rinse
the filter using the FORCED
OPERATION/STOP positions.
If used with MAESTRO, use
position CLOCK.
The lighting interrupter
remains in STOP position.
Control center, basis for settings in an existing installation
Basis for connections and settings in an existing installation
MAESTRO needs to obtain information on filtration; a parallel connection is
made on the filtration contactor coil at the A1 and A2 terminals. 230 V is
present when the filtration runs.
FORCED OPERATION
STOP
AUTO-CLOCK
OPERATION
STOP
FILTRATION
LIGHTING
Never 230 V on the flow switch!
Add a flow switch after the variable speed filtration pump.
! If a variable speed pump is connected!
- RS-485 connections must remain within the building.