Conductivity
pH
ORP
pH
Po
w
er
Da
ta
Fir
m
w
ar
e upda
te via USB
Radio lear
ning
OFF
ON
Tank
pH empt
y
BUS
ORP tank
empt
y
CONDUC
T
ORP
pH
W
ATER T°
AIR T°
Pool
co
ve
re
d
BUS
Po
w
er
Da
ta
PROBES
MAESTRO
®
Water temperature
pH
ORP
Conductivity
P R O B E U N I T
SB-PF-ENS-002D
SB-SE-PRO-001D
S/N 1234ABCD1234ABCD1234ABCD01
QC Passed
Pentair International Sarl
Avenue de Sévelin 18
CH-1004 Lausanne, Switzerland
Mfg Year
Apr-2019
MADE IN ITALY
SCAN
ME
24 V / IP64 / 2.4 W
Manufacturer tag
Serial number
09
Probe Unit (P.U.), description
The multi-sensor measurement makes it possible to find the water values. The length of the cables for the
pH and RedOx probes is voluntarily limited to 50 cm to ensure good probe reading precision.
The service life of the probes (according to the conditions of use) is around 18 years for the pH probe, 5 years
for the RedOx probe and a lifetime for the conductivity and temperature probes.
Only Pentair probes are compatible and guarantee proper functioning of the MAESTRO probe unit (see p40).
Screw cover
(Isolating acid vapours and the circulating humidity)
via the screw hole)
Elastomer cover
(Insulator of acidic vapours
and humidity)
pH probe
pH/ORP probe canister
Probe canister
with (with screw above) = probe out of the water
without = probe in the water
RedOx probe
Conductivity probe
Water temperature probe
Air temperature sensor
(option see p38)
Tighten/loosen the probe bottles.
Never push or pull on the fitted probe bottles
of the end plug
.
The bypass must be isolated by closing the two valves before changing a probe which is at risk
of flooding.
The probe canisters must be filled
with potassium chloride or, failing
this, running water
The cap of the conductivity probe
may not be used for other probes.