Pentair JP09976 / 0 Instruction Manual Download Page 7

7

ENGLISH

Qualification and training of 

personnel

All personnel involved with the operation, 

servicing, inspection and installation of the 

equipment must be suitably qualified for this 

work and must have studied the instruction 

manual in depth to ensure that they are suf-

ficiently conversant with its contents. The su-

pervision, competence and areas of respon-

sibility of the personnel must be precisely 

regulated by the operator. If the personnel do 

not have the necessary skills, they must be 

instructed and trained accordingly.

Safety-conscious working

The safety instructions in this instruction 

manual, the existing national regulations 

regarding accident prevention, and any inter-

nal working, operating and safety regulations 

must be adhered to.

Safety instructions for the 

operator/user

All legal regulations, local directives and 

safety regulations must be adhered to.

The possibility of danger due to electrical en-

ergy must be prevented. 

Leakages of dangerous (e.g. explosive, toxic, 

hot) substances must be discharged such 

that no danger to people or the environment 

occurs. Legal regulations must be observed.

Safety instructions for instal-

lation, inspection and main-

tenance works

As a basic principle, works may only be car-

ried out to the equipment when it is shut 

down. Pumps or plant that convey harmful 

substances must be decontaminated.

All safety and protection components must 

be re-fitted and/or made operational imme-

diately after the works have been completed. 

Their effectiveness must be checked before 

restarting, taking into account the current 

regulations and stipulations.

Unauthorised modifications, 

manufacture of spare parts

The equipment may only be modified or al-

tered in agreement with the manufacturer. 

The use of original spare parts and acces-

sories approved by the manufacturer is im-

portant for safety reasons. The use of other 

parts can result in liability for consequential 

damage being rescinded.

Unauthorised operating 

methods

The operational safety of the supplied equip-

ment is only guaranteed if the equipment is 

used for its intended purpose. The limiting 

values given in the "Technical Data" section 

may not be exceeded under any circumstanc-

es.

Instructions regarding acci-

dent prevention 

Before commencing servicing or maintenance 

works, cordon off the working area and check 

that the lifting gear is in perfect condition.

Never work alone. Always wear a hard hat, 

safety glasses and safety shoes and, if nec-

essary, a suitable safety belt. 

Before carrying out welding works or using 

electrical devices, check to ensure there is 

no danger of explosion.

People working in wastewater systems must 

be vaccinated against the pathogens that 

may be found there. For the sake of your 

health, be sure to pay meticulous attention to 

cleanliness wherever you are working.

Make sure that there are no toxic gases in the 

working area.

Observe the health and safety at work regu-

lations and make sure that a first-aid kit is 

to hand.

In some cases, the pump and the pumping 

medium may be hot and could cause burns. 

For installations in areas subject to explosion 

hazards, special regulations apply! 

This appliance can be used by children aged 

8 years or over and by persons with limited 

physical, sensory or intellectual capabilities, 

or with limited experience and knowledge, 

provided that they are supervised or have 

been instructed in the safe use of the appli-

ance and are aware of the dangers involved. 

Children must not be allowed to play with the 

appliance. Cleaning and user maintenance 

must not be carried out by children unless 

they are supervised. 

USE

The sump BAUFIX 200 is a conventional ef-

fluent collecting sump in conjunction with  

separately ordered pumps.

ATTENTION!

 The Baufix must not be used in 

groundwater endangered areas unless it is 

fitted with the “groundwater seal” accessory, 

up to a maximum pressure load of 3 m water 

column.
The screwed cover is smell-tight and level 

compensating. The integrated and smell-

tight floor drain can be opend on request. 

Depending on the power requirement, vari-

ous pump types can be installed:
Baufix 200-32: U3K, U5K, U6K, US 62, US 73, 

US 102, US 103, US 73 Ex oder US 103 Ex
Baufix 200-50: US 75, US 105, US 155, US 

151, US 251 or US 253. 
The second pump is a reserve pump, accord-

ing to EN 12056. One pump must be able to 

cope with the maximum inflow on its own. 

ATTENTION! 

In some countries it must not 

be used for pumping sewage water from lav-

atories.
The allowed temperature of the pumped me-

dium is 35 °C, short time period 60°C. 
The tank has two inlet connections DN 

100/150 at the side at 90° to each other, a DN 

100 inlet connection, a threaded connection 

(1 1/4" or 2") for the pressure pipe, and a DN 

70 ventilation connection.

Extent of delivery

Baufix underfloor tank, in-tank pressure 

pipe, swing-type check valves, cover frame, 

gasket and cover plate with closing plug.
Closing plug for cable inlet, 4 hose connec-

tors, 8 hose clips, PP pipe, profiled seal, 

complete siphon, 2 90º bends, damp-room 

seal.

Electrical Connection

Please refer to the relevant instructions in 

the manual for the pump.

MOUNTING

The pressure pipe must be taken in a loop 

over the local backpressure level and se-

cured with a reflux valve (EN 12056). The re-

flux valves are supplied with the Baufix 200.

Accessory Groundwater seal

Fix the wall collar to the Baufix with the two 

strap retainers as a sealant against ground-

water.

Installing the tank

1.  Affix the sealing profile with the clamping 

area on the neck of the tank, taking care 

that the sealing cross-section (with the 

sealing lips) is facing inwards. Brush the 

Summary of Contents for JP09976 / 0

Page 1: ...B 48216 10 1705 www jung pumpen de DE Original Betriebsanleitung EN Instruction Manual NL Gebruikshandleiding JUNG PUMPEN BAUFIX 200...

Page 2: ...2 Baufix 200 32 Baufix 200 50...

Page 3: ...3...

Page 4: ...rlicher F rderg ter z B ex plosiv giftig hei m ssen so abgef hrt werden dass keine Gef hrdung f r Personen und die Umwelt entsteht Gesetzliche Be stimmungen sind einzuhalten Sicherheitshinweise f r Mo...

Page 5: ...mit einer Zange gegenhalten 4 Nach Anschluss der erforderlichen Rohr leitungen den Baufix 200 ausrichten und einschl mmen Die komplette Abde ckung bleibt im Baufix um Schmutzein fall zu verhindern 5 D...

Page 6: ...en Schwim merschalter und Saugsieb der Pumpen re gelm ig auf Ablagerungen berpr fen und gegebenenfalls s ubern Die Wartung der Pumpe bitte entsprechend der Betriebsanleitung der Pumpe vorneh men ACHTU...

Page 7: ...may be found there For the sake of your health be sure to pay meticulous attention to cleanliness wherever you are working Make sure that there are no toxic gases in the working area Observe the heal...

Page 8: ...TENTION The mains plug need not be cut off when you feed it up through the ventila tion pipe Installing the float switch set GL Base load Alarm SL Peak load ATTENTION Do not alter the length of the ca...

Page 9: ...pectie en montage moet gekwalificeerd zijn voor dit werk en zichzelf door een grondige bestudering van de handleiding voldoende ge nformeerd Verantwoordelijkheidsgebied competentie en toezicht op het...

Page 10: ...fdichting en afdekplaat met afsluit stoppen Afsluitstoppen voor kabeldoorvoering 4 slangverbinding 8 slangklemmen PP buis afdichtingsprofiel compl sifon 2 hoeken van 90 vochtige ruimtes dichting Elekt...

Page 11: ...armschakeling enkelvou dig systeem Een alarmschakeling waarschuwt voor on toelaatbaar hoge waterstand Deze kan ook op een later tijdstip ingebouwd worden De vlotterschakelaar wordt op de handgreep van...

Page 12: ...JUNG PUMPEN GmbH Industriestr 4 6 33803 Steinhagen Deutschland Tel 49 5204 170 Fax 49 5204 80368 eMail kd jung pumpen de...

Reviews: