background image

OUT

23

28

17

33

42

49

R32 static °C / bar

56

62

67

10
0

-9

-20

72

10 bar = 1 MPa = 145 psi

Classe 1.6

5

10

15

20

35

45

55

30

50

Bar

60

25

40

°C

IVTP-1M-DB

InverTemp™-DB 1M

S/N  1234ABCD1234ABCD1234ABCD01

QC Passed
Pentair International Sarl
Avenue de Sévelin 18
CH-1004 Lausanne

Mfg Year
Nov-2019

MADE IN CHINA

SCAN

ME

230V 50Hz~  /  IPX4  / 2400 W

IN

5,4 kW

6,6 kW

7,8 kW

9,8 kW

11,5 kW 

14,6 kW

4,5 - 4,8 

4,4 - 4,9 

4,9 - 5,2 

4,5 - 5 

4,2 - 4,6 

4,3 - 4,6 

2,6 - 5,4 kW 

3,2 - 6,6 kW 

3,5 - 7,5 kW 

3,7 - 9,8 kW 

4,2 - 11,5 kW 

4,9 - 14,6 kW 

4,5 - 6,7 

4,4 - 6,7 

4,9 - 6,7 

4,5 - 7,0 

4,2 - 6,7 

4,3 - 6,6 

2,6 - 2,9 kW 

3,2 - 3,8 kW 

3,5 - 4,9 kW 

3,7 - 7,8 kW  

4,2 - 6,7 kW 

4,9 - 8,5 kW 

5,6 - 6,7 

5,6 - 6,7

6,1 - 7,1 

5,5 - 7,0 

5,7 - 6,7 

5,6 - 6,6 

2,75 kW

3,35 kW

4,65 kW

5,45 kW

5,8 kW

8,3 kW

2,86

2,82

3,96

3,64

2,83

3

22-32 dB(a)

24-33 dB(a)

27-34 dB(a)

28-39 dB(a)

28-39 dB(a)

29-40 dB(a)

1,5" / 50 mm

230V / 1

+N / 50 Hz

C 10 A

C 10 A

C 10 A

C 16 A

C 20 A

C 20 A

 

3G 2,5 mm²

3G 2,5 mm²

3G 2,5 mm² 

3G 2,5 mm² 

3G 4 mm²

 

3G 4 mm²

 

4 m³/h

5 m³/h

6 m³/h

38 kg

38 kg

44 kg

44 kg

54.5 kg

62.5 kg

Modèle

6,8 kW

8,8 kW

10,6 kW

12,8 kW

16,5 kW

20,1 kW

5,9 - 6,5 

5,5 - 6,5

5,4 - 6,8

5,6 - 6,8

5,1 - 6

5,2 - 5,9

3,2 - 6,8 kW 

3,5 - 8,8 kW 

3,9 - 10,6 kW 

4,2 - 12,8 kW

5,5 - 16,5 kW 

6,5 - 20,1 kW 

5,9 - 10,8 

5,5 - 10,8 

5,4 - 10,8 

5,6 - 11,2 

5,1 - 10,8 

5,2 - 10,1 

3,2 - 5,8 kW 

3,5 - 5,8 kW 

3,9 - 7,1 kW 

4,2 - 8,4 kW 

5,5 - 9,9 kW 

6,5 - 12,2 kW 

8,3 - 10,8 

8,3 - 10,8 

8,3 - 10,8 

8,5 - 11,2 

8,3 - 10,8 

8,1 - 10,1

IVTP-1M-DB

IVTP-2M-DB

IVTP-3M-DB

IVTP-4M-DB

IVTP-5M-DB

IVTP-6M-DB

3

2

DELIVERY TRANSPORT

GENERAL DESCRIPTION

TABLE OF CHARACTERISTICS

Model

IVTP-1M-DB

IVTP-2M-DB

IVTP-3M-DB

IVTP-4M-DB

IVTP-5M-DB

IVTP-6M-DB

Conditions

Dry air temperature: 28°C - Relative humidity: 80% - Input water temperature: 28°C

Heating capacity 

(boost Mode)

Continuous power (COP) 

(boost Mode)

Heating capacity 

(Smart mode)

Continuous power (COP) 

(Smart mode)

Heating capacity 

(Eco mode)

Continuous power (COP) 

(Eco mode)

Conditions

Dry air temperature: 15°C - Relative humidity: 70% - Input water temperature: 28°C

Heating capacity 

(boost Mode)

Continuous power (COP) 

(boost Mode)

Heating capacity 

(Smart mode)

Continuous power (COP) 

(Smart mode)

Heating capacity 

(Eco mode)

Continuous power (COP) 

(Eco mode)

Conditions

Dry air temperature: 7°C - Relative humidity: 0% - Input water temperature: 26°C

Heating capacity

Continuous power (COP)

Sound pressure at 10m

Compressor

Mitsubishi / Toshiba 2D Full DC Inverter

Expansion valve

Electronic

Cabinet

 Reinforced ABS, UV protection and equipped with soundproof panels

Refrigerant

Recyclable refrigerant with no impact on the ozone layer (R32)

Hydraulic connection

Supply voltage

Fuse rating

Power supply cross section

Minimum water flow

Weight

When you have unpacked the HP, please check the content to report any damage. Please also check that the pressure reading on the pressure gauge is equal to 

the pressure mentioned on the box, depending on the measured outdoor temperature, as different values might indicate a leak.

The HP should always be stored and transported in a vertical position, on a pallet and inside its original packaging. 

Transporting and/or storing the HP horizontally will void the guarantee.

Rear protective grid of the evaporator

Manufacturer’s plate

Pressure gauge

Control screen

Water inlet

Hot water outlet

Condensate evacuation

Installation pads 

(under hoods)

Remote fan air outlet

230V AC electric 

supply inlet

RS485 cable passage

(option)

Side protective grids of the evap-

orator

Summary of Contents for INVERTEMP IVTP-1M-DB

Page 1: ...5M DB IVTP 6M DB PENTAIR AQUATIC SYSTEMS Rev 12 2020 i 15 INSTALLATION AND OPERATING MANUAL IMPORTANT SAFETY INSTRUCTIONS PLEASE READ AND FOLLOW ALL THE INSTRUCTIONS KEEP THESE INSTRUCTIONS Download...

Page 2: ...al skills electricity hydraulic refrigeration is authorised to undertake maintenance operations or repairs on the device A qualified technician working on the device must use wear personal protective...

Page 3: ...Dry air temperature 28 C Relative humidity 80 Input water temperature 28 C Heating capacity boost Mode Continuous power COP boost Mode Heating capacity Smart mode Continuous power COP Smart mode Heati...

Page 4: ...Do not direct the fan outlet cold air towards the swimming pool Install it in an open area sound waves bounce off surfaces Install a sound barrier around the HP making sure to maintain the required di...

Page 5: ...etween the two must be greater than 20 cm Filtration pump relay outlet Indicative colour Phase Neutral Earthing Inlet General power supply 230 V 50 Hz Heating priority The filtration pump can be conne...

Page 6: ...w that means that the flow of water through the HP is inadequate Action must therefore be taken by opening or closing progressively the bypass adjustment valve to get the pressure in the recommended r...

Page 7: ...state of the pressure gauge and that the pressure is aligned with the temperature table below and for the presence of coolant 1 Turn off the power supply to the HP 2 Fully open the bypass valve and c...

Page 8: ...e of the evaporator Heating resistance of the compressor Reducer Flow detector Wired controller Black GND Yellow YEL Green GRN Compressor aspiration temp sensor Evaporator temp sensor Ambient temp sen...

Page 9: ...1004 LAUSANNE Switzerland Copyright Limited license unless expressly authorised herein no part of the content of the present document can be reproduced in any form or by any means without the prior wr...