Pentair Hypro 3377 Series Original Instruction Manual Download Page 7

- 7 -

Commissioning, Start-Up, Operation, Shutdown

Before attempting to operate your Cleanload, the following must be understood and followed to ensure safe operation.

Information

Read the operating instructions (to follow) completely before using the Cleanload.

•        Always read and follow the chemical label instructions exactly. Understand safe practices for chemical handling, 

mixing, loading, cleaning, and first aid. 

•        Always wear proper Personal Protective Equipment when handling chemicals, including gloves, eye protection, 

respirator and safety shoes.

•        Always pay attention to wind conditions when using the Cleanload.  DO NOT use Cleanload in wind in excess of 

10MPH due to possibility of tipping.

•        Always check to make sure that there are no loose objects surrounding the Cleanload that could cause damage to 

the hopper tank or hoses.

• 

      When operating the Cleanload at night, ensure proper lighting (200 to 300 Lux) is present.

       IMMEDIATELY SHUT DOWN the system if leaks, errant spray, operation error, or malfunction occur.

Start-up, Operation, Shutdown

 

Before Operation

•  Inspect the assembly for signs of leaks.
•  Ensure check valve is working properly.
•  Inspect window gasket for debris.
•  Inspect latches for wear or aging.
• 

Ensure all hoses or fittings are properly attached to the Closed system Cleanload.

• 

Ensure tank valve (red) and Cyclo rinse valve (grey) are in the closed position and that the inlet handle valve (yellow) 

is in the open position.

• 

Ensure proper pump /system sizing for proper eductor function prior to using chemicals.  Trial with water is 

recommended to ensure safe operation. Proper function is indicated by water being drawn into the line, and not 

backing up inside the enclosure. 

• 

If water backs up in enclosure when the pump is on, ensure the tank valve (red handle)is open to allow flow from the 

enclosure. If the backup persists, immediately close the Cyclo Rinse (gray valve) and the tank valve (red valve, and 

shut off the pump. Review outlet plumbing to minimize restrictions or blockages. 

• 

If gloves become excessively inflated, close tank valve (red handle) immediately and ensure the vacuum relief check 

valve is functioning normally.

Start-up, Operation, Shut Down

1.  Place chemical container(s) in the closed system enclosure and secure the window latches.

2.  Turn on the pump to generate clean water flow.

3.  Open the tank valve (red handle) and the enclosure rinse valve (gray valve).

4.  Inspect assembly for leaks.

5.  Open the chemical container,  pour and measure the chemical. Pour the measured chemical  down through the grate.

6.  Triple rinse the measurement container.

7.  If more than one chemical is needed repeat steps 4 & 5 for a container already in the enclosure.

8.  Rinse chemical container(s) to ensure any chemicals on the exterior are removed.

9.  If container(s) are empty, triple rinse the container(s).

10. Turn  off  the  Cyclo  Rinse  valve  (gray  valve).  Use  hand  to  depress  the  ProClean  bottle  rinse  for  2  min  to  rinse  the 

enclosure.  If using a larger chemical container be sure to move the container and initiate ProClean again to ensure all 

surfaces are adequately rinsed.

11. Turn on the Cyclo rinse valve (gray valve) and run for 30 seconds for a final rinse.

12. Close the Cyclo rinse valve (grey valve) and wait for 15 seconds. Close the tank valve (red handle).

13. Remove chemical container form enclosure. If more chemicals need to be added to the tank repeat steps 1-11.

14. Continue to transfer water as needed or shut off pump. 

Summary of Contents for Hypro 3377 Series

Page 1: ...hypropumps com Hypro Series 3377 Form L 1566 Rev A Original Instruction Manual KEEP FOR FUTURE REFERENCE 3377 1670 3377 1671 3377 1170 3377 1171 Framed Unframed Closed System Cleanload Pentair 375 5th...

Page 2: ...5 Lifting Transport and Intermediate Storage 5 Assembly and Installation 5 Assembly 5 Installation 5 Control Systems 6 Commissioning Start Up Operation Shutdown 7 Information 7 Start Up Operation Shu...

Page 3: ...of this product of procedures that may be dangerous to the user or result in damage to the product ATTENTION Attention is used to notify of installation operation or maintenance information that is i...

Page 4: ...33 L min Operating Temperature 34 115 F 1 46 C Weight 90 lbs 40 8 Kg 3377 1170 3377 1171 Input Pressure PSI Eduction Rate gal sec Flow Rate gal min 20 0 57 27 06 40 0 86 38 09 60 0 85 44 58 80 1 21 50...

Page 5: ...sult the manufacturer s documentation for the equipment on which you are mounting the Cleanload to identify suitable plumbing connections and mounting locations Securely mount the Cleanload in a place...

Page 6: ...All pump systems with electric or hydraulic power sources are required to have a control system which meets all local and national standards For more detail on a typical system installation see preced...

Page 7: ...r being drawn into the line and not backing up inside the enclosure If water backs up in enclosure when the pump is on ensure the tank valve red handle is open to allow flow from the enclosure If the...

Page 8: ...witching chemicals or if the system is going to be inactive for an extended period of time Ensure that the components of the Cleanload are free of any chemical buildup or residue both inside and out F...

Page 9: ...pper outlet with the hopper valve open observe the liquid jet should be centered and straight If it is off center or if it is dispersed flush the system with clean water and remove the fittings from b...

Page 10: ...Valve 23 1 PV1 2F 3607S Nozzle 24 1 3430 0861 Kit Cleanload CS Hose B 1 5 4 12 9 3 6 10 7 8 2 11 22 13 14 18 17 16 15 14 20 21 19 23 24 3377 1670 3377 1671 3377 1170 3377 1170 Replacement Parts The fo...

Page 11: ...Notes 11...

Page 12: ...deration Hypro reserves the right to request a Material Safety Data Sheet from the returnee for any pump product it deems necessary Hypro reserves the right to disposition as scrap products returned w...

Reviews: