Rev. A 1-18-06
15
P/N 620001
Alternate Repair Instructions
STEP 7
1. Attach the No. 8 copper jumper wire to the unused bond lug and tighten the screw frimly.
2. Attach the anode assembly to the jumper wire using the mechanical lug.
3. Tighten all the screws firmly.
4. Position the anode to clear the light fixture and the cord.
a. Ensure the anode is positioned away from the entry hub.
hn-10-11-16-98
Anode
Jumper wire #8
copper bare
Copper Mechanical
Lug
Figure 7.