Page 1: ...WWW HAFFMANS NL HAFFMANS WWW HAFFMANS NL HAFFMANS INSTRUCTION MANUAL INPACK 2000 CO2 METER DIGITAL TYPE ICD...

Page 2: ......

Page 3: ...print or translation errors in this edition of the manual The specifications and design of this product are subject of change without notice All rights reserved No part of this publication may be rep...

Page 4: ......

Page 5: ...5 1 Unpacking 15 6 Operating the CO2 Meter 17 7 Operating the Air Meter 19 7 1 Preparations 19 7 2 Uses of the IAM 20 8 Calibration 23 9 Maintenance and cleaning 25 9 1 ICM 2000 maintenance semi annua...

Page 6: ...HAFFMANS ICD Page 6 of 43 ICD...

Page 7: ...diameter 120 mm Max bottom diameter 92 mm Dimensions Height 550 mm Width 170 mm Depth 250 mm Weight 2 4 kg 1 2 Inpack Air Meter Measuring rangeair content from 0 to 36 ml Subdivision from 0 to 6 ml 0...

Page 8: ...HAFFMANS ICD Page 8 of 43 ICD...

Page 9: ...lled bottles or cans for determination of the CO2 content The ICM 2000 can be used in combination with the Inpack Air Meter The Air Meter is intended exclusively for the measuring of the air content i...

Page 10: ...HAFFMANS ICD Page 10 of 43 ICD...

Page 11: ...ure to observe this information can result in major personal injury or loss of life 3 2 Safety instructions Check glass bottles beforehand for any cracks or breaks Use undamaged bottles only Before th...

Page 12: ...HAFFMANS ICD Page 12 of 43 ICD...

Page 13: ...etween gas and liquid in an enclosed space The law states that at a certain temperature the quantity of gas dissolved in a liquid is proportional to the partial pressure of the gas above the liquid 4...

Page 14: ...head gas The air content of the head gas in a filled can or bottle can be determined by combining the ICC 2000 with the IAM The measuring method is mainly used to check and if necessary adjust the se...

Page 15: ...ntact Haffmans BV or the representative agent designated by Haffmans B V immediately appendix III Always include the serial number order number or invoice number given by Haffmans BV of the ICM 2000 i...

Page 16: ...HAFFMANS ICD Page 16 of 43 ICD...

Page 17: ...hod 1 Bring the bottle or can according to the ASBC standard to a temperature of 25 0 0 2 C 77 0 0 4 F in a water bath This is not strictly necessary but recommended so that measurements can be reprod...

Page 18: ...lay drops to about 0 5 bar and close the needle valve 6 Shaking bottle or can to equilibrium Shake the ICM 2000 with the pierced bottle or can and wait until the manometer value stops increasing 7 Rea...

Page 19: ...e absorbed by 175 ml of lye solution To avoid pressure differences the liquid levels in both tubes must be made equal using the levelling barrel before taking the measurement The following must be car...

Page 20: ...in the hose between the ICM 2000 and the IAM The IAM is now filled with lye without air and is ready to be used for measurements 7 2 Uses of the IAM The IAM has three possible uses which are all based...

Page 21: ...the bottle or can Allow the head gas to escape and then shake the bottle or can immediately together with the ICM 2000 and then allow the gas to escape again Repeat this until no more gas is released...

Page 22: ...HAFFMANS ICD Page 22 of 43 ICD...

Page 23: ...sure 3 Compare the manometer pressure in terms of scale to the precision manometer pressure 4 If the ICM 2000 s manometer reading deviates by more than 1 from the reading on the precision manometer th...

Page 24: ...HAFFMANS ICD Page 24 of 43 ICD...

Page 25: ...le the sealing tap in the IAM fit the red disc first followed by the O ring and then the nut 9 3 ICM 2000 cleaning It is recommended to clean the ICM 2000 daily if measurements have been carried out M...

Page 26: ...HAFFMANS ICD Page 26 of 43 ICD...

Page 27: ...check to see if the screw thread connection between manometer and needle is leaking If so clean the screw thread connection and mount the manometer on the needle with LOCTITE 542 Manometer pos 05 may...

Page 28: ...HAFFMANS ICD Page 28 of 43 ICD...

Page 29: ...ates from the above standard the Haffmans CO2 formula should be adjusted for the constants A C and D Example using beer In beer the solubility of CO2 per 3 Plato changes by about 1 This means that the...

Page 30: ...HAFFMANS ICD Page 30 of 43 ICD...

Page 31: ...r their designated representative agent Always include the serial number order number or invoice number given by Haffmans BV of the ICM 2000 in any correspondence For answers to questions involving th...

Page 32: ...HAFFMANS ICD Page 32 of 43 ICD...

Page 33: ...ecified in the directions for use or which have been exposed to abnormal working conditions or abnormal handling The unlikely event that a defects occurs within the period covered by the guarantee the...

Page 34: ...HAFFMANS ICD Page 34 of 43 ICD...

Page 35: ...CONFORMITY We HAFFMANS B V Marinus Dammeweg 30 5928 PW Venlo Holland declare entirely under our own responsibility that the product CO2 METER TYPE ICM INPACK 2000 upon this statement has reference to...

Page 36: ...HAFFMANS ICD Page 36 of 43 ICD...

Page 37: ...6 05 Manometer 4 bar Manometer 6 bar 001 505 001 462 06 Manometer conductor port 006 376 07 Tube block housing 006 367 08 Needle valve 006 360 09 O ring 1 78 x 1 78 001 048 10 Seal 4 3 x 2 5 004 413 1...

Page 38: ...37 Instrument base 005 025 38 Pan head screw M b 005 036 39 Sticker ICM 03 006 409 40 Hose socket 006 361 41 Clamping bush 4 x 17 006 668 42 Pan head screw with flange M 4x8 006 669 58 Charger R conne...

Page 39: ...ase 5 gr O ring 3 68 x 1 78 36624 007 IAM INP 01 1324 Pos Description Art no 101 Brace 005 790 103 Levelling vessel 004 315 104 Connector nipple 004 727 105 Hose 6x4 mm 004 363 106 Hose 6x4 mm 004 363...

Page 40: ...HAFFMANS ICD Page 40 of 43 ICD...

Page 41: ...e rear position and close the needle valve 1 Preparing IAM Connect to the ICC Fill with lye and remove air from the hose 2 General method Open the needle valve and allow the head gas to bubble through...