10
INSTALLATION AND OPERATION MANUAL – OWNER'S RECORD FFA MANUAL – FILTER FAILURE ALARM
5.1 PROCESS AND APPLICATION CONDITIONS
Stack temperature range
B
–20 to 240°C (–4 to 465°F)
SENSOR – KEY DATA
Flue gas velocity
>4 m/s
Dust level response
<1 to 500 mg/m³ (dependent upon application)
Application conditions
Suitable for measurement in non-condensing flue gases.
Note:
not recommended for deployment downstream of ESPs, or in applications with water
droplets or mist at monitoring point.
Hazardous zone classification
ATEX Zones 2 (Gas) and 22 (Dust)
ENVIRONMENTAL INFORMATION
Altitude category
max. 2,000 m (6,500 ft.)
5.2 SENSOR SPECIFICATION
FILTER FAILURE ALARM MONITOR
Sensor variant
Standard sensor: 0–240°C (up to 465°F)
Probe rod material
316 Stainless Steel, PTFE (insulator)
Weight
900 g (2 lb), excl. rod
Cable entries
2
×
M16 cable glands (one blanked)
ENCLOSURE
Ambient temperature range
B
–20 to +50°C (–4 to 130°F)
Protection rating
IP65
Material
Die-cast aluminium LM6M (epoxy coated)
POWER REQUIREMENTS
Power supply voltage
24 V DC (from the control unit)
5.2.1 Sensor Options
Rod lengths
100 mm (4
″
), 200 mm (8
″
), 300 mm (12
″
), 400 mm (16
″
), 500 mm (20
″
), 600 mm (24
″
), 800 mm (32
″
),
1000 mm (40
″
).
Note:
Imperial measurements are nominal values.
Stack connection
½
″
BSPP (female)
Note:
The opening/port hole in the stack wall must have an ID of at least
∅
19 mm (¾
″
). See section 6.3.2
on page 17 for details
.
B
At monitoring point. Please note that imperial temperatures given are nominal values.
5 TECHNICAL DATA
Summary of Contents for Goyen Mecair FFA
Page 6: ......
Page 40: ...34 INSTALLATION AND OPERATION MANUAL OWNER S RECORD FFA MANUAL FILTER FAILURE ALARM NOTES...
Page 41: ...35 INSTALLATION AND OPERATION MANUAL OWNER S RECORD FFA MANUAL FILTER FAILURE ALARM NOTES...
Page 42: ...36 INSTALLATION AND OPERATION MANUAL OWNER S RECORD FFA MANUAL FILTER FAILURE ALARM NOTES...
Page 43: ...37 INSTALLATION AND OPERATION MANUAL OWNER S RECORD FFA MANUAL FILTER FAILURE ALARM NOTES...