6.5.16
Current day (CD)
Set the current day.
Info
The current day is defined from D1 (Monday) to D7 (Sunday).
1. Press
or
to set the current day.
2. Press
to validate the selection and move to the next parameter.
6.5.17
Flow meter type (FM)
Select the flow meter type.
Options:
• P0.7: ¾" paddle wheel meter (Standard setting for 4600, 5600 and 9100);
• t0.7: ¾" turbine meter;
• P1.0: 1" paddle wheel meter (Standard setting for 2750 and 9000);
• t1.0: 1" turbine meter;
• P1.5: 1½" paddle wheel meter (Standard setting for 2850);
• t1.5: 1½" turbine meter;
• P2.0: 2" paddle wheel meter;
• Gen: generic or other non-Fleck meter.
1. Press
or
to set the flow meter type.
2. Press
to validate the selection and move to the next parameter or exit
master programming mode and save modifications done.
6.5.18
Meter pulse (K)
Set the meter pulse for a non-standard flow meter.
Info
The meter pulse parameter is only available if the Gen option has been set in flow
meter type selection.
1. Press
or
to set the meter constant in pulses per unit of volume.
2. Press
to validate the selection and to exit the master programming
mode.
Summary of Contents for FLECK 9100 SXT
Page 1: ...www pentairaquaeurope com INSTALLER MANUAL FLECK 9100 SXT COMMERCIAL...
Page 73: ...Installer manual Fleck 9100 SXT Maintenance Ref MKT IM 004 E 06 10 2020 73 108...
Page 75: ...Installer manual Fleck 9100 SXT Maintenance Ref MKT IM 004 E 06 10 2020 75 108...
Page 77: ...Installer manual Fleck 9100 SXT Maintenance Ref MKT IM 004 E 06 10 2020 77 108...
Page 80: ...Installer manual Fleck 9100 SXT Maintenance 80 108 Ref MKT IM 004 E 06 10 2020...
Page 82: ...Installer manual Fleck 9100 SXT Maintenance 82 108 Ref MKT IM 004 E 06 10 2020...
Page 84: ...Installer manual Fleck 9100 SXT Maintenance 84 108 Ref MKT IM 004 E 06 10 2020...
Page 87: ...Installer manual Fleck 9100 SXT Maintenance Ref MKT IM 004 E 06 10 2020 87 108...