background image

Page 31

1” & 1 1/2” Plastic Turbine Meter

.

Item No. 

Quantity 

Part No. 

Description

.

1.................... 1.....................

17542

.......................

Flow Straightener, 1 1/2”

.

2.................... 1.....................

40576

.......................

Clip, H, Plastic, 7000

.

3.................... 1.....................

40577

.......................

Turbine Meter Assy, 7000

.

4.................... 1.....................

41555

.......................

Body, Remote Meter

 

5

.................... 1.....................

40951

.......................

O-ring, -220

.

6.................... 1.....................

40563

.......................

Connector, 1” NPT, 7000

 

7

.................... 1.....................

40563-10

..................

Connector, 1” BSP, 7000

 

8

.................... 1.....................

40565

.......................

Connector, 1 1/4” NPT, 7000

 

9

.................... 1.....................

40565-10

..................

Connector, 1 1/4” BSP, 7000

.

10.................. 1..................... 41242.......................

Connector, 1” & 1 1/4” Sweat

.

11.................. 1..................... 41243.......................

Connector, 1 1/4” & 1 1/2” Sweat

.

12.................. 1.....................

41596

.......................

Connector, Brass, 1” NPT

.

13.................. 1.....................

41596-10

..................

Connector, Brass, 1” BSP

.

14.................. 1.....................

41597

.......................

Connector, Brass, 1 1/2” NPT

 

15

.................. 1.....................

41597-10

..................

Connector, Brass, 1 1/2” BSP

.

16.................. 1.....................

61560-01

..................

Meter Assy, In-Line, w/1” NPT Plstc Connector

 

 

 

61560-02

..................

Meter Assy, In-Line, w/1” BSP Plstc Connector

 

 

 

61560-03

..................

Meter Assy, In-Line, w/1 1/4” NPT Plstc Connector

 

 

 

61560-04

..................

Meter Assy, In-Line, w/1 1/4” BSP Plstc Connector

 

 

 

61560-05

..................

Meter Assy, In-Line, w/1” & 1 1/4” Sweat Connector

 

 

 

61560-06

..................

Meter Assy, In-Line, w/1 1/4” & 1 1/2” Sweat Connector

 

 

 

61560-07

..................

Meter Assy, In-Line, w/1” NPT Brass Connector

 

 

 

61560-08

..................

Meter Assy, In-Line, w/1” BSP Brass Connector

 

 

 

61560-09

..................

Meter Assy, In-Line, w/1 1/2” NPT Brass Connector

 

 

 

61560-10

..................

Meter Assy, In-Line, w/1 1/2” BSP Brass Connector

Summary of Contents for Fleck 3200NT

Page 1: ...3200NT Service Manual IMPORTANT Fill in Pertinent Information on Page 3 for Future Reference...

Page 2: ...ime of printing The manufacturer reserves the right to make changes at any time without notice This manual is intended as a guide for service of the valve only System installation requires information...

Page 3: ...on LEAd or LAg Remote System Start Off or On Signal Time needed _____ minutes Display Format US Gallons or m3 Unit Capacity ____________ Grains or Degrees Capacity Safety Factor Zero or ______ Regener...

Page 4: ...ving to this regeneration step position Once all regeneration steps are complete the timer returns to In Service and resumes normal operation Start a Regeneration Tonight With metered delayed timers p...

Page 5: ...on The timer retains all values without loss The timer is fully inoperative and any calls for regeneration are delayed The timer upon power re application resumes normal operation from the point that...

Page 6: ...y display alternates with the Volume Remaining display gallons or m3 As treated water is used the Volume Remaining display counts down from the calculated system capacity to zero or When this occurs a...

Page 7: ...on queued until the other valve goes into standby The exhausted valve goes into standby after completing Regeneration All units remain In Service except those in standby or Regeneration Water flow thr...

Page 8: ...s 2 Set Feed Water Hardness The feed water hardness setting displays only if the Regenera tion Type is set to Meter Immediate or Meter Delayed Press the Set Up and Set Down buttons to set the amount o...

Page 9: ...the maximum amount of time in days the unit can be In Service without a Regeneration For System 4 Time Clock regeneration mode the system regenerates at the time set in Step 4 after the number of days...

Page 10: ...a Cycle button once per display until all displays are viewed and Normal Display is resumed 4 Option setting displays may be changed as required by pressing either the Set Up or Set Down button 5 Depe...

Page 11: ...Page 11 Master Programming Mode Flow Chart CAUTION Before entering Master Programming please contact your local professional water dealer...

Page 12: ...Page 12 Master Programming Mode Flow Chart CAUTION Before entering Master Programming please contact your local professional water dealer...

Page 13: ...Page 13 Master Programming Mode Flow Chart CAUTION Before entering Master Programming please contact your local professional water dealer...

Page 14: ...umes Resetting Permanent Programming Memory Press and hold the Set Up and Set Down buttons for about 25 seconds until the Time Of Day display resets to 12 00 P M All option settings reset to default v...

Page 15: ...Immediate Alternating Setting 7 FI This is a 2 unit system with only one unit having a meter and only one unit in service When the volume of treated water drops to zero 0 in the unit in service it req...

Page 16: ...just this value Press the Extra Cycle button 7 Unit Capacity Display Code C This program step sets the capacity of the system in kilograins or m3 X degrees for metric systems The letter C in the first...

Page 17: ...is step For any Meter System Types the system regenerates after the number of days programmed in this step at the same time of day that the previous regeneration occurred unless the meter initiates a...

Page 18: ...ration cycle timing Range Total time of Regeneration Cancel Setting AroF Turn on Start of Regeneration S 0 Shut off End of Regeneration E 92 Turn on after 10 minutes in Regeneration S 10 Shut off afte...

Page 19: ...s taking place if the System Type is 7 or 9 NOTE The length of time CALc displays is dependent on the calculated volume and could be a minute or more Time of Day Finish the control programming by sett...

Page 20: ...Remaining L Display Code X 1 000 000 Range 1 000 000 2 900 000 t Display Code X 1000 Range 10 000 999 999 No Display Code Range 1 9 999 Zero Calculating the Volume Remaining Communication Error Progra...

Page 21: ...he Extra Cycle button once per display until all displays are viewed and Normal Display is resumed 3 Press and release the D button at anytime during diagnostic mode and the timer will exit the mode 4...

Page 22: ...til all are viewed The Diagnostic Mode is exited and normal operation resumes Pressing the Diagnostic button while in the Diagnostic Mode will cause the unit to leave the Diagnostic Mode and return to...

Page 23: ...ayed Display example 67 Range 0 to 999 hours Depress the Extra Cycle button 6 Volume Remaining Volume remaining will be adjustable when displayed in this mode Regeneration will occur if set to zero fo...

Page 24: ...y Code X 1000 Range 10 000 999 999 No Display Code Range 1 9 999 Hours Between Last Two Regenerations II Display Code Range 1 199 Hours Since Last Regeneration Display Code Range 1 199 Adjustable Volu...

Page 25: ...Page 25 Notes...

Page 26: ...Page 26 Power Head Assembly 2750 2850 2900 Upper Drive and 2900 Lower Drive...

Page 27: ...former US 120V 24V 108VA 3200NT 41049 Transformer Euro 230V 24V 41050 Transformer Aust 230V 24V 9 1 40943 Wire Harness Lower Drive w Molded Strain Relief 10 1 40388 Motor Drive 24V 50 60 Hz 11 1 19121...

Page 28: ...Page 28 Power Head Assembly 3150 3900 Upper Drive and 3900 Lower Drive...

Page 29: ...34 Transformer US 120V 24V 108VA 3200NT 41049 Transformer Euro 230V 24V 41050 Transformer Aust 230V 24V 9 1 40943 Wire Harness Lower Drive w Molded Strain Relief 10 1 19121 08 Meter Cable Assy NT 35 w...

Page 30: ...50 2 1 13882 Post Meter Impeller 3 1 13509 Impeller Meter 4 1 13847 O ring 137 Std 560CD Meter 5 1 14716 Meter Cap Assy ET NT 6 4 12112 Screw Hex Hd Mach 10 24 x 1 2 18 8 S S 7 1 14960 Flow Straighten...

Page 31: ...PT 13 1 41596 10 Connector Brass 1 BSP 14 1 41597 Connector Brass 1 1 2 NPT 15 1 41597 10 Connector Brass 1 1 2 BSP 16 1 61560 01 Meter Assy In Line w 1 NPT Plstc Connector 61560 02 Meter Assy In Line...

Page 32: ...1 13509 Impeller Meter 4 1 13847 O Ring 137 Std 560CD Meter 5 1 14716 Meter Cap Assy ET NT 6 4 17798 Screw Hex Hd Mach 10 24 x 1 2 18 8 S S 7 1 17542 Flow Straightener 1 1 2 8 1 12733 O Ring 132 9 1 1...

Page 33: ...ring 227 Meter 3 1 14568 Fitting Nipple 2 4 1 14680 Flow Straightener 5 1 14569 Nut 2900 Meter 6 1 15532 Seat Impeller Shaft Hex 7 1 15432 Shaft Impeller SS 8 1 15374 Impeller Assy 2 Meter 9 1 13847...

Page 34: ...ly 2 Plastic Electronic 5 1 15374 Impeller Assy 2 Meter 6 1 13847 O Ring 137 Std 560CD Meter 7 14716 Meter Cap Assy ET NT 8 4 12473 Screw Hex Wsh 10 24 x 5 8 18 8 S S 9 2 40666 Seal Face 2 Plastic Met...

Page 35: ...0 2 1 16279 Shaft Impeller 3 1 16575 Impeller Assy 3 4 1 14716 01 Meter Cap Assy 3 ET 5 3 15707 O ring 236 6 6 12112 Screw Hex Hd Mach 10 24 x 1 2 7 1 16280 Flow Straightener 8 2 16328 Adapter Flange...

Page 36: ...Page 36 2750 2850 Timer Wiring Diagram...

Page 37: ...Page 37 3150 Timer Wiring Diagram...

Page 38: ...Page 38 2900 Timer Wiring Diagram...

Page 39: ...Page 39 3900 Timer Wiring Diagram...

Page 40: ...Page 40 3200NT Remote Timer Wiring Diagram 42073_REVA...

Page 41: ...Page 41 2750 2850 3200NT Remote Wiring Diagram 42074_REVA...

Page 42: ...Page 42 3150 3200NT Remote Wiring Diagram 42076_REVA...

Page 43: ...Page 43 2900 3200NT Remote Wiring Diagram 42075_REVA...

Page 44: ...Page 44 3900 3200NT Remote Wiring Diagram 42077_REVA...

Page 45: ...ect phone or extension cables first before programming System Type 7 and 6 flow meter cable must be connected to the timer programmed as the LEAd Timer 2 A maximum cable length of 100 cable can be use...

Page 46: ...Ground Wire on Transformer 2750 2850 2900 Valves Installing Ground Wire on Transformer 3150 3900 Valves Installing and Grounding the Transformer 1 Locate the ground label to find ground screw 2 Remove...

Page 47: ...n prior to the error and regeneration is queued according to the normal system operation If reprogramming the unit in the Master Programming Mode clears the error the volume remaining may be reset to...

Page 48: ...4 units retain their normal display and do not display PErr Cause Correction A One or more timers are programmed as System type different from the LEAd unit A Programming the units correctly in the M...

Page 49: ...Page 49 Notes...

Page 50: ...Page 50 Notes...

Page 51: ...Page 51 Notes...

Page 52: ...P N 41093 Rev E 9 06...

Reviews: