Installer manual Fleck 3150 NXT/NXT2 - Programming
104 / 182
Ref. MKT-IM-010 / C - 18.10.2019
a) Set the safety coefficient with
,
and ;
ð
Can be adjusted from 0 to 50%;
ð
Any value programmed above the maximum value
will be discarded and considered as the maximum
above mentioned value.
b) Press to validate the selection and advance to the
next parameter.
No safety factor
programmed.
Fixed volume
Set a fixed volume as safety reserve capacity.
Info
The availability depends on reserve type programmed in the previous step.
a) Set the reserve volume with
,
and ;
ð
The volume range depend on capacity, in liter if
metric units were programmed or US gallon if US
units were programmed (see Units [
Page 101] );
ð
The maximum reserve volume capacity settable
will correspond to the half of the total volume.
b) Press to validate the selection and advance to the
next parameter.
6.2.5.19
Remote regeneration
Set the regeneration type for remotely started regeneration (external dry contact input,
see chapter Electrical connections [
Page 52]).
Info
This mode can be combined with the other methods of regeneration; the remotely
started regenerations overrule the other regeneration type once the signal is acquired.
Options:
• off;
• immediate;
• delayed.
a) Set the remote regeneration mode with
and
;
ð
Default setting: off;
b) Press to validate the selection and advance to the
next parameter.
Remote regeneration
deactivated.
Summary of Contents for FLECK 3150 NXT
Page 1: ...FLECK 3150 NXT NXT2 INSTALLER MANUAL WATER PURIFICATION ...
Page 139: ...Installer manual Fleck 3150 NXT NXT2 Maintenance Ref MKT IM 010 C 18 10 2019 139 182 DC motor ...
Page 144: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 144 182 Ref MKT IM 010 C 18 10 2019 ...
Page 148: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 148 182 Ref MKT IM 010 C 18 10 2019 ...
Page 182: ...www pentairaquaeurope com ...