Installer manual Fleck 3150 NXT/NXT2 - Programming
Ref. MKT-IM-010 / C - 18.10.2019
101 / 182
a) Set regeneration type with
and
;
ð
Default regen. type: time clock;
b) Press to validate the selection and advance to the
next parameter.
6.2.5.13
Units
Set the unit system to be used.
Options:
• US: volume in gallons, time display 2 x 12 hours, hardness in grains;
• metric: volume in liter, time display 24 hours and hardness depends on hardness
unit set (see Hardness units [
a) Set the unit system with
and
;
ð
Default system unit: US;
b) Press to validate the selection and advance to the
next parameter.
6.2.5.14
Volume override/ Volumetric
Set the volume of water between 2 cleaning/regeneration cycles.
Info
Available only for filter metered systems.
a) Set the volume override with
,
and ;
ð
Can be adjusted from 0 to 9’999’999 liter;
b) Press to validate the selection and advance to the
next parameter.
6.2.5.15
Hardness units
Set hardness unit system to be used.
Info
This screen is displayed only if units mode programmed is metric (Units [
Info
1°F = 10 mg/L CaCO
3
= 10ppm CaCO
3
= 0.56°dH = 0.7 °eH
Options:
• mg/L;
• °DH: German;
Summary of Contents for FLECK 3150 NXT
Page 1: ...FLECK 3150 NXT NXT2 INSTALLER MANUAL WATER PURIFICATION ...
Page 139: ...Installer manual Fleck 3150 NXT NXT2 Maintenance Ref MKT IM 010 C 18 10 2019 139 182 DC motor ...
Page 144: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 144 182 Ref MKT IM 010 C 18 10 2019 ...
Page 148: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 148 182 Ref MKT IM 010 C 18 10 2019 ...
Page 182: ...www pentairaquaeurope com ...