16
WATER YOU CAN TRUST
®
WHEN TO CHANGE THE CARTRIDGES
The life of the cartridges depends on the water volume used
and the substances in the water. Normally, cartridges should
be changed at intervals of 12 months. Replace the cartridges
sooner if the water pressure at the application equipment
begins to drop noticeably or if you notice changes in the flow
of the blended water.
CHANGING THE CARTRIDGES
Replacement Cartridges:
Everpure 4FC5 Filter Cartridge - EV9693-21
Everpure 4CC Mineral Cartridge - EV9627-45
Pentair
®
GRO-75EN RO Membrane Cartridge - 4002575
The 4FC5 and 4CC Cartridges need to be changed when
replacing the GRO-75EN RO Membrane Cartridge. All
cartridges should be changed at the same time.
NOTE: Only the replacement cartridges listed can be used
with this processor. Failure to use the recommended
replacement cartridges will void your warranty.
1. Place a small pan or towel under the Everpure Conserv
LT-S Processor to catch any water that may drip. Turn
OFF incoming water.
2. Close the ball valve on the the Storage Tank and OPEN
the application equipment valve to relieve pressure.
3. Remove the two (2) cartridges by twisting each cartridge
a 1/4-turn to the left (counterclockwise). Then pull down
to release.
4. Remove the GRO-75EN RO Membrane Cartridge by
removing the tubing from all three (3) connections. Then
pull the cartridge out of the clip.
5. At the bottom of the cartridge, remove the quick-connect
elbow from the red tubing to gain access to the flow
controller and the attached capillary tube. Replace the
flow controller (Figure 13) in the red tubing.
6. Insert a new flow controller (Figure 13) with capillary
tube into the tubing. Replace the quick-connect elbow.
Flow
Controller
Red Tubing
White
Tubing
Blue
Tubing
Figure 13
7. Insert the new GRO-75EN RO Membrane Cartridge into
position in the clip. Rotate the cartridge so the quick-
connect ports line up with the tubing.
8. Push the red and blue tubing into the quick-connect
ports at the bottom. Push the top white tubing into the
connector at the top of the cartridge.
NOTE: The bottom of the GRO-75EN RO Membrane Cartridge
will be supported by the lower bracket.
9. Position the 4FC5 Cartridge under the left side head.
Line up the tabs on the cartridge with the slots in the
head.
10. Push the new cartridge into the head until it can go no
further.
11. Twist the cartridge a 1/4-turn to the right (clockwise)
until it locks in place. Pull gently down to ensure the
cartridge is locked in place.
12. Flush the 4FC5 Cartridge following the procedure in the
Installation Instructions in Step 5.
13. Repeat Steps 10, 11 and 12 for the 4CC Cartridge in the
front center head.
CAUTION: The 4CC Cartridge may contain carbon fines that
will be removed during the initial flushing. Follow
the proper flushing procedure to prevent damage
to the GRO-75EN RO Membrane Cartridge.
INITIAL FLUSHING OF CARTRIDGES
The installation of new cartridges requires that a preliminary
flushing of the cartridges be performed. This initial flushing
is required to prevent damage to the RO cartridge.
Refer to the Installation section for the complete flushing
procedure.