background image

 16 

WATER YOU CAN TRUST

®

WHEN TO CHANGE THE CARTRIDGES

The life of the cartridges depends on the water volume used 

and the substances in the water. Normally, cartridges should 

be changed at intervals of 12 months. Replace the cartridges 

sooner if the water pressure at the application equipment 

begins to drop noticeably or if you notice changes in the flow 

of the blended water.

CHANGING THE CARTRIDGES

Replacement Cartridges:

Everpure 4FC5 Filter Cartridge - EV9693-21
Everpure 4CC Mineral Cartridge - EV9627-45
Pentair

®

 GRO-75EN RO Membrane Cartridge - 4002575

The 4FC5 and 4CC Cartridges need to be changed when 

replacing the GRO-75EN RO Membrane Cartridge. All 

cartridges should be changed at the same time. 

NOTE: Only the replacement cartridges listed can be used 

with this processor. Failure to use the recommended 

replacement cartridges will void your warranty.

1.  Place a small pan or towel under the Everpure Conserv 

LT-S Processor to catch any water that may drip. Turn 

OFF incoming water.

2.  Close the ball valve on the the Storage Tank and OPEN 

the application equipment valve to relieve pressure.

3.  Remove the two (2) cartridges by twisting each cartridge 

a 1/4-turn to the left (counterclockwise). Then pull down 

to release.

4.  Remove the GRO-75EN RO Membrane Cartridge by 

removing the tubing from all three (3) connections. Then 

pull the cartridge out of the clip.

5.  At the bottom of the cartridge, remove the quick-connect 

elbow from the red tubing to gain access to the flow 

controller and the attached capillary tube. Replace the 

flow controller (Figure 13) in the red tubing.

6.  Insert a new flow controller (Figure 13) with capillary 

tube into the tubing. Replace the quick-connect elbow.

Flow 

Controller

Red Tubing

White 

Tubing

Blue 

Tubing

Figure 13 

7.  Insert the new GRO-75EN RO Membrane Cartridge into 

position in the clip. Rotate the cartridge so the quick-

connect ports line up with the tubing.

8.  Push the red and blue tubing into the quick-connect 

ports at the bottom. Push the top white tubing into the 

connector at the top of the cartridge.

NOTE: The bottom of the GRO-75EN RO Membrane Cartridge 

will be supported by the lower bracket.

9.  Position the 4FC5 Cartridge under the left side head. 

Line up the tabs on the cartridge with the slots in the 

head.

10. Push the new cartridge into the head until it can go no 

further.

11. Twist the cartridge a 1/4-turn to the right (clockwise) 

until it locks in place. Pull gently down to ensure the 

cartridge is locked in place.

12. Flush the 4FC5 Cartridge following the procedure in the 

Installation Instructions in Step 5.

13. Repeat Steps 10, 11 and 12 for the 4CC Cartridge in the 

front center head.

CAUTION: The 4CC Cartridge may contain carbon fines that 

will be removed during the initial flushing. Follow 

the proper flushing procedure to prevent damage 

to the GRO-75EN RO Membrane Cartridge.

INITIAL FLUSHING OF CARTRIDGES

The installation of new cartridges requires that a preliminary 

flushing of the cartridges be performed. This initial flushing 

is required to prevent damage to the RO cartridge.
Refer to the Installation section for the complete flushing 

procedure.

Summary of Contents for EVERPURE CONSERV LT-S

Page 1: ...ounting the Conserv LT S Processor inspect the parts Use the table and illustration provided to verify the parts provided If any parts are missing contact Customer Service at 800 942 1153 US only 630 307 3000 or by email at CSeverpure pentair com Parts 1 Wall Unit with GRO 75EN RO Membrane Cartridge in Place 2 4CC Mineral Cartridge 3 4FC5 Filter Cartridge 4 Storage Tank 5 Parts Bag Containing Bypa...

Page 2: ...s restricted to trained adult personnel No one should play with the appliance NOTE Children should be supervised to ensure that they do not play with the appliance NOTE Cleaning and user maintenance shall not be made by children without supervision NOTE The appliance is not suitable for installation in an area where a water jet could be used NOTE If the supply cord is damaged it must be replaced b...

Page 3: ...d NOTE Substances listed as reduced are not necessarily in your water The Processor must be maintained according to manufacturer s instructions including replacement of filter cartridges NOTE Your water must be within required limits for satisfactory operation If not the RO membrane cartridge s life may be shortened and your warranty will be voided see Operating Specifications NOTE Install on cold...

Page 4: ...4 WATER YOU CAN TRUST EVERPURE CONSERV LT S PROCESSOR 1 Secure Unit to Wall Approximately 25 lbs 11 3 kgs Operating Weight 1 3 2 Remove RO Membrane 2 3 ...

Page 5: ...ge Tank 3 Connect Tubing for Flushing Precharge Storage Tank 5 7 psi 0 34 bar 0 034 MPa 3 8 Tubing Product Water Out 1 3 2 4 3 8 Tubing To Storage Tank 3 8 Tubing Supply Water In CLOSE OPEN 4 Prepare to Flush the Everpure 4FC5 Cartridge 1 3 2 Connect Electrical Install Bypass Plug CLOSE Unplugged Inlet Water ...

Page 6: ...e 4FC5 Cartridge 1 2 4FC5 OPEN Plugged 1 4 Inlet Water Install Cartridge Flush to Drain Five 5 Minutes 2 3 5 Plug In Power Cord Unplug Power Cord Closed Valve As Shown 6 Prepare the Pentair GRO 75EN Cartridge for Use Replace Membrane 2 Remove Cover 1 ...

Page 7: ...rtridge Storage Tank Not Shown 1 Remove Plug Push White 3 8 Tubing into White Connector 3 2 4 Push Red 3 8 Tubing into Red Connector Push Blue 3 8 Tubing into Blue Connector 8 Flush Pentair GRO 75EN Cartridge Plug In Power Cord Inlet Water Open Flush To Drain for 24 Hours 1 4 2 3 Fully CLOSE Turn To Right Unplug Power Cord ...

Page 8: ...d Open 2 Solid Blue Blending Valve 1 4 Turn or Less 2 Solid Blue Blending Valve 1 4 Turn or Less 5 2 4 Repeat Until Flashing Blue Blending Valve 1 8 Turn Press Press 1 3 6 Plug In Power Cord Unplug In Power Cord OPEN One 1 Full CCW Turn of the Valve ...

Page 9: ...9 EVERPURE CONSERV LT S HIGH EFFICIENCY RO SYSTEM INSTALLATION AND OPERATION GUIDE 10 Install Everpure 4CC Cartridge 1 2 4CC 1 Remove Port Plug 2 Install 4CC Cartridge ...

Page 10: ...10 WATER YOU CAN TRUST 11 Flush Storage Tank and 4CC Cartridge 3 2 CLOSE OPEN 1 When Pump Turns Off OPEN valve 5 4 Plug In Power Cord Repeat Steps 2 and 4 Four 4 Times ...

Page 11: ...more water the system is required to produce the longer the membrane will last INSTALLATION NOTE Please read all instructions specifications and precautions before installing and using your Conserv LT S Processor NOTE The Conserv LT S Processor may be installed hanging on a wall or set under a sink NOTE The Conserv LT S Processor must be installed vertically WARNING Improper connection of the appl...

Page 12: ...er end to the Storage Tank and insert it into the ball valve The ball valve should be closed 5 Connect a length of 3 8 O D tubing to the Everpure Conserv LT S Processor outlet connection Secure an open ball valve to the other end and position it over a drain Water Supply Inlet Figure 3 4 Prepare to Flush the Everpure 4FC5 Cartridge The Everpure 4FC5 Filter Cartridge is installed and flushed before...

Page 13: ... connect ports that are labeled Inlet White Product RO Water Blue Drain Red White Port Figure 7 CAUTION DO NOT remove the quick connect elbow fitting from the red tubing This assembly contains a flow control that may become damaged if removed The efficiency of the Everpure Conserv LT S Processor may be affected 1 Remove the GRO 75EN RO Membrane Cartridge from its packaging and position it with the...

Page 14: ... depress blue cap Do not submerge entire unit 4 One 1 or two 2 lights will light immediately Match light s to the chart to get approximate range of Total Dissolved Solids TDS Release the blue cap and write down the TDS range 0 75 ppm solid blue 76 150 ppm flashing blue 100 250 ppm flashing blue solid green 251 300 ppm solid green 301 400 ppm flashing green 401 500 ppm solid green flashing green 50...

Page 15: ...ck the tank air pressure Ensure that the tank has 5 7 psi 0 34 bar 0 034 MPa of precharge upon installation Add air if needed Tank pressure may be checked using an air pressure gauge on the air valve on the side of the tank Blended Water Outlet Figure 12 1 OPEN the ball valve on the top of the Storage Tank 2 CLOSE the ball valve at the blended water out tubing 3 Apply power It will take approximat...

Page 16: ... access to the flow controller and the attached capillary tube Replace the flow controller Figure 13 in the red tubing 6 Insert a new flow controller Figure 13 with capillary tube into the tubing Replace the quick connect elbow Flow Controller Red Tubing White Tubing Blue Tubing Figure 13 7 Insert the new GRO 75EN RO Membrane Cartridge into position in the clip Rotate the cartridge so the quick co...

Page 17: ...high quality silicone lubricant Replace the central plug assembly and insert the flushing cartridge into the left side head for the Everpure 4FC5 Cartridge NOTE Do not use petroleum jelly to lubricate the o rings It will degrade the o rings 2JT Plug 4CC Port Connect White and Blue Tubing Cartridge with Sanitizer Figure 15 6 Install a plug into the port for the 4CC Filter Cartridge NOTE A plug was ...

Page 18: ... 3 Unscrew the tank valve from the storage tank 4 Inspect the rubber seal inside the threaded area Repair or replace the valve as needed 5 Thread the tank valve onto the top of the tank opening by turning it clockwise until snug 6 Wet the tubing and insert it 3 4 1 9 cm into the quick connect fitting 7 Turn water supply ON and CLOSE the application valve 8 Allow processor to pressurize for several...

Page 19: ...nstallation must comply with state and local regulations Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts Substances that may be reduced are not necessarily in your water Filter must be maintained according to manufacturer s instructions including replacement of filter cartridges The efficiency rating for this system is 56 31 Efficiency ratin...

Page 20: ...re technical service at the phone number listed below Any part found materially defective within the terms of this warranty will be repaired or replaced at PFS s discretion by your local dealer or Pentair Everpure technical service You pay only freight from our factory and local dealer charges Any item repaired or replaced pursuant to this warranty will be covered under the original warranty terms...

Reviews: