Pentair EVERPURE CONSERV 75E EV9977-00 Original Instructions Manual Download Page 12

 12 

EVERPURE

®

 CONSERV

®

 75E HIGH EFFICIENCY RO SYSTEM INSTALLATION AND OPERATION GUIDE

5

 Install the Everpure 4CB5 Filter Cartridge

Locate the 4CB5 Filter Cartridge and inspect the o-rings. 

They should be clean and lightly lubricated with silicone 

grease.

1.  Line up the tabs with the slots in the opening on the front 

right side of the head assembly.  See Figure 6 and  

Figure 7.

2.  Insert the cartridge to full depth.
3.  Rotate the cartridge 90

0

 to the right (clockwise) to lock it 

in place.

Install the Everpure 4CC Mineral Cartridge

Locate the 4CC Cartridge and inspect the o-rings. They 

should be clean and lightly lubricated with silicone grease.

1.  Line up the tabs with the slots in the opening on the left 

front side of the head assembly. See Figure 6 and  

Figure 7.

2.  Insert the cartridge to full depth.
3.  Rotate the cartridge 90

0

 to the right (clockwise) to lock it 

in place.

Storage Tank

The storage tank will hold approximately 1 gallon (3.8 L) of 

product water. The tank air pressure is preset to 24 psi (1.65 

bar, 0.16 Mpa) when shipped via ground transportation. For 

air shipments the precharge is completely removed. Check 

the tank air pressure. Ensure that the tank has 24 psi (1.65 

bar, 0.16 Mpa) of precharge upon installation. Add air if 

needed. Tank pressure may be checked using an air pressure 

gauge on the air valve at the bottom of the tank.
Locate the valve at the top of the tank and turn OFF until 

instructed to open it.

PUTTING THE SYSTEM INTO OPERATION

CAUTION: If wall mounted, make certain the unit is firmly 

attached to wall to prevent it from falling and 

possibly becoming damaged.

NOTE: The Everpure Conserv 75E System does not produce 

a high volume of water on-demand as an ordinary 

filter does. Water is produced at a slow, drop-by-

drop rate. The system requires about 30 minutes to 

fill the storage tank. As water is taken from the tank, 

the system automatically starts the cycle of replacing 

the water and then stops water production when the 

tank is full.

There are several steps that must be followed to properly 

place the Conserv 75E System into operation before the 

supply water is turned ON.

6

 Flush the Everpure 4FC5-S Filter Cartridge

Electrical 

On/Off

Blended 

Water 

Shut-off

Blending 

Valve

Incoming 

Water 

Shut-off

Tank Valve

Flush Port for 

4FC5-S Cartridge

Figure 8 

1.  The incoming water shut-off valve should be in the 

closed position. 

2.  The electrical switch must be in the off position
3.  Locate the quick-connect tee fitting on the 4FC5-S Filter 

Cartridge head. Remove the plug by pressing in on the 

collar and pulling out on the plug. Save the plug to be 

reinstalled later. 

4.  Cut a length of 3/8" (9.5 mm ) long enough to connect 

the flush port to a drain. Push one end of the tubing, 5/8" 

(16 mm), into the quick-connect fitting. The other end is 

secured at a drain.

5.  The power to the Conserv 75E RO System must remain 

off. Turn the incoming water shut-off to OPEN. Water will 

flush through the 4FC5-S Cartridge to the drain.

6.  Flush the cartridge for five (5) minutes. Then CLOSE the 

incoming water shut-off valve.

7.  Remove the temporary tubing from the flush port. 

Reinsert the plug that was removed in Step 3.

Summary of Contents for EVERPURE CONSERV 75E EV9977-00

Page 1: ...m inspect the parts Use the table and illustration provided to verify the parts and quantities provided If any parts are missing contact Customer Service at 800 942 1153 US only 630 307 3000 or by email at CSeverpure pentair com Parts 1 Back Panel Assembly 2 GRO 75EN RO Membrane Cartridge 3 4CC Mineral Cartridge 4 4FC5 S Filter Cartridge 5 Cover 6 4CB5 Filter Cartridge 7 TDS Meter 8 Support Leg 9 ...

Page 2: ...atment utility or a certified water testing lab to determine the quality of your water Temperature 32 100 F 0 37 7 C Dynamic Operating Pressure 40 85 psi 2 7 5 8 bar 0 27 0 58 MPa non shock Maximum Static Pressure 125 psi 8 6 bar 0 86 MPa Total Dissolved Solids 1 000 ppm maximum Sulfide Iron and Manganese Less than 0 1 ppm Water Supply pH Limits 4 to 11 Turbidity 1 0 NTU maximum For cold water use...

Page 3: ...The Conserv 75E System contains filter cartridges and an RO membrane cartridge included with the system that have limited service lives critical for the effective reduction of total dissolved solids Product water should be tested periodically to verify that the system is working properly WARNING The Conserv 75E System shall only be used for arsenic reduction on chlorinated water supplies containin...

Page 4: ...NSERV 75E SYSTEM 1 Secure Manifold Wall Mount 2 Tubing Locations NOTE Feet may be removed 58 lbs 26 kgs Power Cord Blended RO Water 3 8 Tubing to the Application Waste Water 1 4 Tubing to Drain Supply Water In 3 8 Tubing Filtered Water 3 8 Tubing to the Application Accessory Tank 3 8 Connection ...

Page 5: ...STEM INSTALLATION AND OPERATION GUIDE 3 Install Pentair GRO 75EN RO Membrane Cartridge Blue Red White GRO 75EN 1 3 2 GRO 75EN 6 5 4 4 Install Everpure 4CC Mineral Filter 4CB5 Filter and 4FC5 S Filter Cartridges 1 2 1 2 4CC 4FC5 S 4CB5 3 16 90 1 2 ...

Page 6: ...r Supply Filtered Water 3 8 Tubing Accessory Tank Connection 3 8 Tubing NOTE Maximum 6 gal 22 7L Accumulator tank size Set recharge to 25 psi 1 72 bar 0 17 MPa PUT SYSTEM INTO OPERATION QUICK START 6 Flush Everpure 4FC5 S Filter Cartridge Insert 3 8 Tube Closed Power Off 1 3 Closed 5 4 6 7 8 Closed Remove Plug Install Plug Insert 3 8 Tubing Remove 3 8 Tubing Replace Plug Open Flush for Five 5 Minu...

Page 7: ...dge 1 Closed 7 Open Flush for 24 Hours Open 9 4 Closed Insert 3 8 Tubing 2 Power Off 5 Power On 8 6 Open Tank Valve 3 8 Final Flush Power On 1 3 NOTE During the final flush the storage tank and the 4CC Mineral Cartridge are flushed When Pump Stops Open for Five 5 Minutes Repeat Four 4 Times Close for 30 Minutes Open 2 ...

Page 8: ...SYSTEM INSTALLATION AND OPERATION GUIDE 9 Set Blending Valve Power On Blending Valve Closed Open Open 2 Solid Blue Blending Valve 1 4 Turn 2 Solid Blue Blending Valve 1 4 Turn 1 2 3 Repeat Until Flashing Blue Blending Valve 1 8 Turn Press Press ...

Page 9: ...p on the membrane as scale The more water the system is required to produce the longer the membrane will last INSTALLATION NOTE Please read all instructions specifications and precautions before installing and using your Conserv 75E System NOTE The Conserv 75E System may be installed hanging on a wall under a sink or sitting on a counter NOTE The Conserv 75E System must be installed vertically Gro...

Page 10: ... line s to the equipment being serviced CLOSE the inlet and outlet valves on the RO system Reapply pressure to the plumbing by slowly OPENING the shut off valve that was closed in the previous step 5 Connect a 1 4 7 14 mm OD tube to the reject connector labeled DRAIN located in the lower left corner of the unit Route the other end of the tubing to a drain nearby securing it properly Allow an air g...

Page 11: ...white port at the top NOTE The top cover of the Everpure Conserv 75E System must be removed 2 Slide the cartridge into position through the back of the top support 3 Press the cartridge into the clip on the back plate The cartridge may be moved up or down to line up with the tubing connections 4 Insert RO inlet connection into the white quick connect port of the RO filter 5 Insert drain water conn...

Page 12: ...AUTION If wall mounted make certain the unit is firmly attached to wall to prevent it from falling and possibly becoming damaged NOTE The Everpure Conserv 75E System does not produce a high volume of water on demand as an ordinary filter does Water is produced at a slow drop by drop rate The system requires about 30 minutes to fill the storage tank As water is taken from the tank the system automa...

Page 13: ...he 4CC Mineral Cartridge and 4CB5 Filter Cartridge will be flushed when the storage tank is flushed No further flushing is required CAUTION Visually check the entire system for leaks If a leak is present see Troubleshooting NOTE Initially the water may appear cloudy This is a result of air trapped in the postfilter cartridge It is not harmful and will disappear in a matter of minutes It may take u...

Page 14: ...ubstances in the water Normally cartridges should be changed at intervals of 12 months Replace the cartridges sooner if the water pressure at the application equipment begins to drop noticeably or if you notice changes in the flow of the blended water CHANGING THE CARTRIDGES Replacement Cartridges Everpure 4FC5 S Filter Cartridge EV9693 31 Everpure 4CC Mineral Cartridge EV9627 45 Pentair GRO 75EN ...

Page 15: ...ter system has been contaminated or a boil water advisory has been discontinued the Everpure Conserv 75E System must be sanitized If a boil water advisory has just been discontinued Flush the water lines according to your water supplier s instructions OPEN the delivery faucet and flush the system for about 10 minutes then follow the filter cartridge replacement instructions below 1 Turn OFF the wa...

Page 16: ... top and blue bottom system tubing 28 Install a new GRO 75EN RO Cartridge Connect the three 3 tubes to the proper ports The tubing and the ports are color coded 29 OPEN the water supply valve and the application valve 30 With the power switch in the on position allow the application valve to drip for 12 hours 31 CLOSE the application valve The storage tank will fill Check for leaks during this tim...

Page 17: ...re in the storage tank to 25 psi 1 72 bar 0 17 MPa 6 Replace the black cap 7 OPEN the incoming water valve until it comes to a stop Let the system run one 1 to three 3 hours to fill the tank A full tank weighs approximately 29 4 lbs 10 2 kgs pounds If performance has not improved call Technical Support Sudden Return of Taste and Odor If shortly after complete servicing noticeable taste and odors r...

Page 18: ...4FC5 S Filter Cartridge EV9693 31 4CC Mineral Cartridge EV9627 45 4CB5 Filter Cartridge EV9617 11 Storage Tank EV3146 55 TDS Meter EV3125 98 Plug 3 8 inch Quick Connect EV3144 87 Port Plug EV3108 76 Waste Water Restrictor EV3128 31 Conserv 75E Cartridge Kit EV9977 25 Conserv 75E Tested and Certified by NSF International against NSF ANSI 58 for the reduction of claims specified on the Performance D...

Page 19: ...e of accessories or components which do not meet PFS s specifications Refer to the specifications section in the Installation and Operating manual for approved application parameters Our product performance specifications are furnished with each water treatment unit TO THE EXTENT PERMITTED BY LAW EVERPURE DISCLAIMS ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY A...

Page 20: ...3175 AUSTRALIA 011 1300 576 190 TEL 011 61 39 562 7237 FAX AU EVERPURE PENTAIR COM EMAIL EVERPURE SHURFLO CHINA 21F CLOUD 9 PLAZA NO 1118 SHANGHAI 200052 CHINA 86 21 3211 4588 TEL 86 21 3211 4580 FAX CHINA WATER PENTAIR COM EMAIL EVERPURE SHURFLO INDIA GREEN BOULEVARD B 9 A 7TH FLOOR TOWER B SECTOR 62 NOIDA 201301 91 120 419 9444 TEL 91 120 419 9400 FAX INDIACUSTOMER PENTAIR COM EMAIL EVERPURE SHU...

Reviews: