11
EVERPURE
®
CONSERV
®
75E HIGH EFFICIENCY RO SYSTEM INSTALLATION AND OPERATION GUIDE
3
Install the Pentair GRO-75EN RO Membrane
Cartridge
The GRO-75EN RO Membrane Cartridge is installed in the
vertical position. There are three (3) quick-connect ports that
are labeled:
• Inlet - White
• Permeate (RO blended water ) - Blue
• Drain - Red
Blue Red
RO Inlet Connection
White
Drain
Connection
RO Water
Tubing
GRO-75EN
3
1
2
4
5
6
Figure 5
The numbers in Figure 5 refer to the Steps below.
CAUTION: DO NOT remove the quick-connect elbow fitting
from the red tubing. This assembly contains
a flow control that may become damaged if
removed. The efficiency of the Everpure Conserv
75E System may be affected.
1. Remove the GRO-75EN RO Membrane Cartridge from its
packaging and position it with the single white port at the
top.
NOTE: The top cover of the Everpure Conserv 75E System
must be removed.
2. Slide the cartridge into position through the back of the
top support.
3. Press the cartridge into the clip on the back plate. The
cartridge may be moved up or down to line up with the
tubing connections.
4. Insert RO inlet connection into the white quick-connect
port of the RO filter.
5. Insert drain water connection into the red quick-connect
port of the RO filter.
6. Insert RO water connection into the blue quick-connect
port of the RO filter.
4
Install the Everpure 4FC5-S Filter Cartridge
Locate the 4FC5-S Filter Cartridge and inspect the o-rings.
They should be clean and lightly lubricated with silicone
grease.
1. Line up the tabs with the slots in the opening on the front
right side of the head assembly. See Figure 6 and Figure 7.
2. Insert the cartridge to full depth.
3. Rotate the cartridge 90
0
to the right (clockwise) to lock it
in place.
Figure 6
1
2
1
2
4C
C
4FC5-S
4CB5
Figure 7