Page 20
Menu / Setting Parameters
1. On main interface screen, press
MENU
(SET)
for 5 seconds to enter into parameter setting menu.
Press
UP
(HEAT/COOL)
and
DOWN
(DEFROST)
buttons to navigate to each parameter. Refer to table below for a list of
all parameters.
2. On parameter setting interface,press
MENU
(SET)
to enter into parameter setting menu. Press
UP
(HEAT/COOL)
and
DOWN
(DEFROST)
buttons to modify parameter value. Press
MENU
(SET)
again to save value and go back to
parameter setting menu.
3. Press
ON/OFF
(UNLOCK)
at any time to confirm settings and go back to main interface.
Code Parameter Name
Description
Range
Default
L2
Temperature
Differential
Set how much the water temperature needs to
drop below the set temperature, for the heat
pump to start up again. E.g. If the set temperature
is 28
0
C and the water temperature is 28
0
C, the
heat pump will stop heating and not restart until
the water temperature drops to 26
0
C (if the Tem-
perature Differential is set to 2
0
C).
1-25
0
C
2
0
C
L3
Heat Mode Temp
This is the set temperature when in Heat mode.
5-40
0
C
28
0
C
L4
Cool Mode Temp
This is the set temperature when in Cool mode.
5-32
0
C
12
0
C
L5
Compressor Cur-
rent
Configuration