background image

For Cable Sizes

14-2 Through 10-3

With Ground

Metal and wood stud, and flanges up to 1/16"

Double runs of MC/AC cable from structural members, wires, and rods

Figure 2

Figure 1

Figure 3

Figure 4

Figure 5

Figure 6

Figure 7

Figure 8

Figure 9

Figure 10

Figure 11

*Note: MAC2 snaps apart for single applications. Assemblies do not have this feature.

Part Number Figure

Description (in [mm])      Attaches MC/AC to:

MAC2

1

Metal or wood stud and 1/16" [2] flange

MAC2T

2

Supports 1 to 4 runs of MC/AC cable for metal stud

MAC2ATA

3

Acoustical tee

MAC2BC

4

1/8" [3] through 1/2" [13] flange

MAC224SM

5

1/8" [3] through 1/4" [6] flange

MAC258SM

5/16" [8] through 1/2" [13] flange

MAC2912SM

1/2" [13] through 3/4" [19] flange

MAC2VF14

6

1/16" [2] through 1/4" [6] C Purlin or vertical flange

MAC2123

7

Z purlin

MAC2AO

8

Offset bracket

MAC224

9

1/8" [3] through 1/4" [6] flange - bottom mount, rotates 360

MAC258

5/16" [8] through 1/2" [13] flange - bottom mount, rotates 360

MAC2912

9/16" [14] through 3/4" [19] flange - bottom mount, rotates 360

MAC21318

13/16" [21] through 1-1/8" [28] flange - bottom mount, rotates 360

MAC24Z34

10 #12 through 1/4" [6] wire, plain or threaded rod and 1/8" [3] through 3/8" [10] flange

MAC26Z34

3/8" [10] plain or threaded rod and 3/8" [10] through 9/16" [14] flange

MAC2FB

11

Through metal stud

TECHNICAL SUPPORT:

www.erico.pentair.com

CFS242_F

INSTRUCTION SHEET

1 OF 4

© 1997-2017 Pentair All Rights Reserved

MAC2 Series

MC/AC Support Clips

WARNING:

Pentair products shall be installed and used only as indicated in Pentair product instruction sheets and training materials. Instruction sheets are available at 

1.

www.erico.pentair.com and from your Pentair customer service representative.  

PENTAIR products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.

2.

All instructions must be completely followed to ensure proper and safe installation and performance.  

3.

Improper installation, misuse, misapplication or other failure to completely follow Pantair's instructions and warnings may cause product malfunction, property 

4.

damage, serious bodily injury and/or death, and void your warranty.

Products that are manufactured using spring steel components shall be used only in a non-corrosive indoor environment. 

5.

All pipe supports, hangers, intermediate components and structural attachments must ONLY be used as described herein and are NEVER to be used for any 

6.

other purpose.

NOTE: All load ratings are for static conditions and do not account for dynamic loading such as wind, water or seismic loads, unless otherwise noted.
The customer is responsible for:

a. Conformance to all governing codes.

b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified 

engineer.

c. Using appropriate industry standard hardware as noted above.
SAFETY INSTRUCTIONS: 

All governing codes and regulations and those required by the job site must be observed. 

Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.

Pentair, CADDY, ERICO CADWELD, ERICO CRITEC, ERICO, ERIFLEX, and LENTON are owned by Pentair or its global affiliates. All other trademarks

are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.

Summary of Contents for Caddy MAC2 Series

Page 1: ...tair com and from your Pentair customer service representative PENTAIR products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings 2 All instructions must be completely followed to ensure proper and safe installation and performance 3 Improper installation misuse misapplication or other failure to completely follo...

Page 2: ...ood studs Flange Application Figure 4 Figure 3 Figure 2 Figure 1 Part Number Figure Application MAC2 1 Metal or wood stuf and 1 4 6 flange MAC2T 2 1 to 4 runs of MC AC to metal stud Part Number Figure Aplication MAC2ATA 3 1 or 2 runs of MC AC to accoustical tee bar Part Number Figure Application MAC2BC 4 1 or 2 runs of MC AC to 1 8 3 through 1 2 13 flange TECHNICAL SUPPORT www erico pentair com CF...

Page 3: ...of MC AC to 5 16 8 through 1 2 13 flange MAC2912SM 1 or 2 runs of MC AC to 1 2 13 through 3 4 19 flange Part Number Figure Application MAC2VF14 6 1 or 2 runs of MC AC to 1 16 2 through 1 4 6 C purlin or vertical flange MAC2123 7 1 or 2 runs of MC AC to Z purlin Part Number Figure Application MAC2AO 8 Offset bracket for 1 or 2 runs of MC AC cable TECHNICAL SUPPORT www erico pentair com CFS242_F INS...

Page 4: ...hrough 3 4 19 flange bottom mount rotates 360 MAC21318 1 or 2 runs MC AC to 13 16 21 through 1 1 8 28 flange bottom mount rotates 360 Part Number Figure Application MAC24Z34 10 12 through 1 4 6 wire plain or threaded rod and 1 8 3 through 3 8 10 flange for 1 or 2 runs of MC AC MAC26Z34 3 8 10 plain or threaded rod and 3 8 10 through 9 16 14 flange for 1 or 2 runs of MC AC Part Number Figure Applic...

Reviews: