background image

LIMITED WARRANTY

Pentair Water Pool and Spa, Inc. ("Pentair Water") manufactures its products with the highest standards of workmanship,
using the best materials available through state of the art process. Pentair Water warrants its products as follows:

Limited Warranty: 

 Pentair Water warrants its products to be free from defects in material and/or workmanship for a

period of three (3) years or 8,000 hours (parts only) from the original date of installation.

Exceptions that could result in denial of a warranty claim:

1.

Damage caused by careless handling, improper repackaging, or shipping.

2.

Damage due to misapplication, misuse, abuse or failure to operate equipment as specified in the owners

manual.

3.

Damage caused by failure to install products as specified in the owners manual.

4.

Damage due to unauthorized product modifications or alterations, or failure to use Pentair Water original

replacement parts.

5.

Damage caused by negligence, or failure to properly maintain products as specified in the owners manual.

6.

Damage caused by failure to maintain water chemistry in conformity with the standards of the swimming pool

industry for any length of time.

7.

Damage caused by water scaling, freezing or other conditions causing inadequate water circulation.

8.

Accidental damage, fire, acts of God, or other circumstances outside the control of Pentair Water.

This warranty extends to the original retail owner only, beginning on the date of installation and is not

enforceable by any other party.  Proof of purchase and/or date of installation will be required to execute a
warranty claim.  Original owner agrees to repay all shipping charges to Pentair Water Pool and Spa Inc.

Warranties by others: Some products incorporate components manufactured by other manufacturers. Some of

these provide warranties in addition to the warranty provided herein. In all such cases a copy of that warranty
will be provided with the product. To the extent protection provided under any such third party warranty
exceeds the Limited Warranty provided herein, the Customer will have to look to that manufacturer for the
additional warranty protection.

Warranty Obligations of Pentair Water: 

Should a defect in workmanship and/or material in any item covered by this

warranty become evident during the term of the warranty, then upon the consumer following the procedures set forth
below, Pentair Water will, at its option, repair or replace such item or part at its own cost and expense.

Pentair Water is not, however, responsible under this warranty for any cost of shipping or transportation of the equipment
or parts thereof to or from the Technical Service Department.   Also, Pentair Water is not liable for any loss of time,
inconvenience, incidental expenses such as telephone calls, labor or material charges incurred in connection with the
removal or replacement of the equipment, or any other incidental or consequential damages.

PLEASE NOTE: Some states do not allow the exclusion or limitation of incidental, or consequential damages, so the
above limitation or exclusion may not apply to you.

No Other Warranties: TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, PENTAIR WATER DISCLAIMS
ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

Procedure for Obtaining Performance: 

In order to obtain the benefits of this warranty, the consumer who made the

original retail purchase must contact the Pentair Water Technical Service Department upon discovery of the defect, but in
no event later than the expiration date of the warranty period provided in this warranty.  Upon receipt of this
communication, Pentair Water will promptly notify the customer of the address to which the defective item may be
shipped.  The customer shall then ship the item, freight prepaid, to the address indicated, together with a "RETURN
GOODS AUTHORIZATION" form obtained from Technical Service and a brief description of the problems encountered.
Unauthorized returns will not be accepted.  Freight must be prepaid by customer.

Warranties or Representations by Others: 

 No dealer or other person has any authority to make any warranties or

representations concerning Pentair Water or its products.  Accordingly, Pentair Water is not responsible for any such
warranties or representations.

Other Rights:

 This warranty gives you specific legal rights and you may also have other rights, which vary from state to

state. This warranty supersedes all previous publications.

PENTAIR WATER POOL AND SPA, INC.

1620 Hawkins Ave. Sanford, NC 27330  - 10951 W. Los Angeles Ave. Moorpark, CA 93021 - Phone 800-831-7133 - Fax 800-284-4151

Summary of Contents for C20

Page 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Installation Guide IntelliChlor Power Center For use with IntelliChlor model IC20 and IC40 Patents pending ...

Page 2: ...0 Trademarks and disclaimers IntelliChlor IntelliTouch EasyTouch and the Pentair Water Pool and Spa logo are trademarks of Pentair Water Pool and Spa Inc Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products Pentair Water Pool and Spa Inc disclaims proprietary interest in marks and names of others P N 520590 Rev...

Page 3: ...Support iii Introduction 1 Power Center Overview 1 IntelliChlor Models 1 Operating Instructions 2 Installation 2 Kit Contents 2 RequiredTools 2 SAFETY PRECAUTIONS 2 Installing the Power Center 3 Troubleshooting 5 Electrical Specifications and 110 VAC and 220 VAC Wiring 6 220 VAC Basic System Wiring 6 110 VAC Basic System Wiring 6 ...

Page 4: ...r water circulation A build up of flammable gases will result in hazardous conditions CAUTION When using IntelliChlor with an IntelliTouch system it is recommended to wire the IntelliChlor Power Center to the pump side of the relay located in the IntelliTouch Load Center This wiring method does not require a ground fault circuit interrupter GFCI to protect the circuit A green colored terminal or a...

Page 5: ...5 P M Phone 800 831 7133 Fax 919 566 8920 Moorpark California 8 A M to 5 P M Phone 800 831 7133 Fax 805 530 0194 Web sites visit www pentairpool com and www staritepool com 1 3 2 4 Declaration of Conformity We declare under our sole responsibility that the product identified in this declaration and to which this declaration relates are in conformity with the protection requirements of Council Dire...

Page 6: ...bottom of the enclosure for additional protection There are no other controls or lights on the outside of the Power Center A green power LED indicator is mounted on the inside main board When the Power Center is switched on the power LED is lit IntelliChlor Models The IntelliChlor salt chlorinator system models are PC 100 P N 520556 Power Center Kit IC 20 Cell P N 520554 Designed for pools up to 2...

Page 7: ...onnector to the grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying this equipment The power supply must be interconnected with pool pump motor power source This insures the IntelliChlor chlorinator and pool pump will switch on and off together Grounding earth bonding is required The unit should be installed by a quali...

Page 8: ...er see the IntelliChlor User s Guide P N 520589 Mount the Power Center enclosure 1 Remove the screw securing the Power Center cover and remove the cover 2 Mount the Power Center on a flat surface such as a wall or post and mark each mounting bracket screw hole location There are two 2 screw holes and a keyslot for the top and lower bracket 3 Drill six inch 6 35 mm holes Install anchors if necessar...

Page 9: ...The Power Center should be connected to the pump motor switch or automatic timer For system wiring information see page 6 7 Attach incoming GROUND wire to the ground lug inside the Power Center 8 Earth Bonding Grounding Connect the earth wire to the GROUND BONDING LUG located on the bottom of the Power Center enclosure Earth bonding is necessary to ensure personal safety and safety of equipment IM...

Page 10: ...b 24 hour 317 gm 24 Hour IntelliChlor Model IC40 Input 90 130 VAC 50 60 Hz 220 Watts 2 AMP or 220 240 VAC 50 60 Hz 220 Watts 1 AMP Output 22 39 VDC 6 AMPS maximum from the Power Center Chlorine 1 40 lb 24 Hour 635 gm 24 Hour IMPORTANT When using IntelliChlor with an IntelliTouch system it is recommended to wire the Power Center to the pump side of the relay located in the IntelliTouch Load Center ...

Page 11: ...6 IntelliChlor Power Center Installation Guide Notes ...

Page 12: ...ed by this warranty become evident during the term of the warranty then upon the consumer following the procedures set forth below Pentair Water will at its option repair or replace such item or part at its own cost and expense Pentair Water is not however responsible under this warranty for any cost of shipping or transportation of the equipment or parts thereof to or from the Technical Service D...

Page 13: ...P N 520590 Rev C ...

Reviews: