6
•
Autotrol
®
Performa Valve with 400 Series Control water Conditioning Control System
Capacity Setting
Move the jumper to the set of pins next to the word CAPACITY
(Figure 9). Press the black TIME SET button until the correct
capacity value is displayed. The capacity range is 1 to 99
kilograins. Refer to the Suggested Salt Dial Settings table (1).
Return the jumper to the top set of pins next to the word TIME
and replace the access door. The jumper must NOT be left
on any pins other than the top pair next to the word TIME.
Otherwise, the unit may show a blank display.
NotE:
A spare jumper is located on the bottom set of pins.
In the event that the hardness or capacity setting must be
changed, simply follow the appropriate steps described above.
Calendar override Setting
1. Disconnect power.
2. Place jumper on Pin A and reconnect power.
3. Move jumper to Pin B. A zero will appear, indicating
zero days of calendar override. All 460i controllers are
preprogrammed in this manner at the manufacturer.
4. Depress the black TIME SET button. The numbers will roll
from “0” to “15.” Release the switch at the desired number
of days for the calendar override. For example, releasing
the switch at “10” would program a 10-day
calendar override.
5. Disconnect power.
6. Place jumper back on TIME and reconnect power.
7. The calendar override program is maintained during power
outages by the NOVRAM circuitry.
8. To remove the calendar override, follow the same steps
above and program back to “0.”
460tC Control
460TC
DAYS
CLOCK
PM Indicator
Hour Time Display
Access
Door
Indicator Knob
Timer Locking Pin
Raised Tab
Jumper
Spare
Jumper
Transformer
Plug Receptacle
Time Set Button
Figure 10
Programming
Plug the wall-mount transformer into a functioning electrical
outlet that is not controlled by a switch. Plug the transformer
into the transformer plug receptacle on the control.
Open the access door by pushing the raised tab on the door
toward the left while pulling the tab out (Figure 10).
time of Day Setting
With the jumper on the set of pins next to the word TIME
(Figure 11), set the time of day to the closest hour by pressing
the black TIME SET button. PM hours are indicated by a light
next to the letters PM on the display window.
NotE:
the use of a small needle-nose pliers will aid in
moving the jumper.
NotE:
the unit is factory set to regenerate at 2:00 a.m. If
you prefer to have the unit regenerate at an earlier
or later time, simply set the current time of day
accordingly (e.g., to have the unit regenerate at 4:00
a.m.—two hours later—set the clock two hours
earlier than the actual time of day).
NotE:
the timer locking Pin should always be horizontal
(Figure 10) during operation.
Days Setting
Move the jumper to the set of pins next to the word DAYS
(Figure 12). Press the black TIME SET button until the desired
number of days between regeneration is displayed. The range
is from 1 to 30 days.
TIME
DAYS
CLOCK
TIME
DAYS
CLOCK
TIME
DAYS
CLOCK
Figure 11
Figure 12
Figure 13
Clock Setting
Move the jumper to the set of pins next to the word CLOCK
(Figure 13). Press the black TIME SET button until the desired
clock setting is displayed. The clock range is 0 or 1. Select 0
for the standard AM/PM clock or select 1 for a 24 hour clock.
Return the jumper to the top set of pins next to the word TIME
and replace the access door. The jumper must NOT be left
on any pins other than the top pair next to the word TIME.
Otherwise, the unit may show a blank display.
NotE:
A spare jumper is located on the bottom set of pins.
400 SErIES CoNtrol SEttINgS