Section  I.

Installing Fountain Light Fixture — Niche Mount

A.

Preparatory steps which must be completed by the electrician before the light fixture is installed:

1. Verify that the fountain meets the requirements of the current National Electrical Code and all local codes and ordinances.

A licensed or certified electrician must install the electrical system to meet or exceed those requirements before the
underwater light is installed.

2. Verify that the lighting circuit

has a Ground Fault Circuit
Interrupter (GFCI) for line
voltage models and has an
appropriately rated circuit
breaker.

3. The wet niche must be properly

installed so that the top of the
underwater light's lens is at
least 2 inches below the
surface of the water.

4. The wet niche must be properly

electrically bonded and
grounded via the #8 AWG
ground connector located at
the rear of the niche.

B. Steps to perform after the

electrical system requirements
are met:

1. Assemble the screws and nuts

to the stainless steel face ring
of the light being used. See
Figure 1.

2. Feed the cord through conduit

to the Junction Box, leaving
some length of cord at the
light fixture to coil around the
light. This length of cord around
the light allows the light to be
pulled out of the water and
serviced conveniently without having to disconnect the light from the J-Box.

3. Ensure that the length of exposed cord in the fountain is no more than 10 ft. (3 m).

4. Cut the cord at the Junction Box, leaving at least 6 inches of cord to make connections.

5. Strip 6 inches of the outer cord jacket to expose the three insulated wires – be careful not to damage the insulation

on the three inner wires.

6. Connect all three wires to the corresponding circuit wires in the Junction Box and secure the Junction Box cover

in place.

7. Place the light assembly into the niche and tighten special pilot screw.

8. Position and secure the rock guard with the acorn nuts provided. To ensure proper positioning, align the pilot screw

of the light with the pilot screw hole of the rock guard. Refer to Figure 1.

Fountain Niche Kit for Large Lights

Figure 1.

Light

Rock

Guard

Rock

Guard

Screws

Retaining

Nut

Acorn

Nut

Niche

Pilot Screw

Pilot Screw Hole

Rock

Guard

Pilot Screw

Light

Rock

Guard

Screws

Retaining

Nut

Rock

Guard

Screws

Acorn

Nut

Niche

Pilot Screw Hole

Fountain Niche Kit for Small Lights

Rock

Guard

Light

Face Ring

Retaining

Nut

Acorn

Nut

Rock

Guard
Screw

Assembly View

Reviews: