![Pentair 522352 Installation Manual Download Page 40](http://html.mh-extra.com/html/pentair/522352/522352_installation-manual_1524360040.webp)
32
EASYTOUCH
®
PL4/PSL4 Control System Installation Guide
System Start-Up
The following information describes basic start-up procedures. For more detailed troubleshooting
information, refer to the EasyTouch PL4/PSL4 Systems User’s Guide (P/N xxxxxx). Before you
power up the Power Center check the following:
Check Electronics
Check that the following plugs are seated correctly on the Personality board:
• Relay connectors -
FLTR PUMP
-
AUX1 - AUX3
• Temperature sensors connectors
WATER, SOLAR, AIR
• Transformer conductor harness
J1
attached to the EasyTouch PL4/PSL4 Control System
circuit board.
• Heater control connector
ELEC HTR
or two-conductor screw terminal.
Refer to Summary Installation Steps (page 5) and Power Center System Wiring Diagrams, on page
Testing the auxiliary relays
Affix the auxiliary relay labels to the appropriate buttons on the EasyTouch PL4/PSL4 Control
System control panel. If necessary, write the function on the control panel.
•
Toggle the filter pump, each auxiliary circuit, heater and solar and verify the function. Press
the SYSTEM CONTROL button to set the system in
“AUTO”
mode when done.
System Test
The following describes how to test the Outdoor Control Panel to activate the heater, valves and
pumps. This test assumes that all system equipment has been properly installed and connected to
the Power Center.
Testing Valve Actuators and Pumps
Use the following steps to test the valve actuators (CVA24T) for proper rotation for PSL4 Control
System (shared equipment).
To test the valve actuators and pump:
1. Power up the Power Center.
2. Press the
MODE
button on the Outdoor Control Panel until the
SERVICE
is displayed on
the screen.
3. Press the
V (Valve)
button to select
POOL.
4. Press the
F
(Filter Pump)
button to activate the filter pump. Water will be removed from
the pool and returned to the pool.
5. Set both valve actuators (CVA-24T) for suction and return. Use the toggle switch on the
rear of the CVA-24 to withdraw and return water from the pool.
Note:
With the filter pump operating, if the water is not being removed and returned to the
pool, it may be necessary to reverse the
RETURN
with
INTAKE
plugs on the EasyTouch
PL4/PSL4 Control System circuit board.