Example: IntelliValve
™
Valve Actuator on Return Valve to Split
to Pool /Spa for Spillway Effect
Home position at 6 (Red LED on)
To allow partial water flow to the spa/spillway port, set an end point position at 6. To allow
complete water flow to spa/spillway set the other end point diverter position at 24. The
valve actuator will now travel between positions 6 and 24 while normally residing at Home
position 6.
Diverter Seal at Home Position 6
Diverter position 6
(LED on) there is partial
restriction of water flow
for spa/spillway.
POSITION 6
POSITION 6
INLET
Home position 6
(Red LED on)
WATER FLOW DIRECTION
(PARTIAL WATER FLOW)
INLET
OUTLET
WATER FLOW
DIRECTION
WATER
FLOW
DIRECTION
DIVER
TER
POSITION
Press MODE button to toggle between:
AUTO Mode
(Green LED on):
The IntelliValve Valve
WARNING!
DO NOT mount the IntelliValve so that the SUCTION or return line of the
pump can be blocked. This will cause permanent pump damage.
Actuator is controlled automatically when connected to a
OFF Mode
(Red LED on):
Press SAVE button until AUTO LED is red.
SET Mode
(Blue LED on):
Mode changes to SERVICE (Yellow LED on). Press MODE, select AUTO.
Press or button to set endpoint
Press or button to set endpoint nearest to 24. Press SAVE.
SERVICE Mode
(Yellow LED on):
Use or to move valve diverter
position manually. Settings are not retained after exiting Service mode.
supported automation control system.
nearest to 0. Press SAVE.
+ to change Home position to opposite endpoint.
Diverter moves to Home position (Red LED on). If required, press
POOL
SP
A/
SPILL
W
A
Y