Changing Home Position
The Home position is where the diverter normally resides. While in AUTO mode the
Home position can be charged to the other diverter end point. The factory default
diverter end point positions are 0 and 24 with “0” being the “Home” position. The diverter
will move between these two end points. This is similar to toggling the switch (ON1/ON2)
on a standard valve actuator which causes the valve to move to the opposite end point.
To change the Home position:
When in AUTO mode, press the
Red arrow button
and Yellow arrow button
simultaneously. The diverter will rotate to the other end point
(the new home position). The factory default home position is 0.
Changing the end point will move it to from Position 0 to Position 24, which changes
the direction of the diverter. If custom diverter end point are established, it will toggle
between the two established end points.
In the example below, the Red LED is at position 24 which now
represents the current
position of the valve’s internal diverter seal which is OFF (fully blocked). In this position
the diverter seal restricts water flow on the left side port.
Diverter at end point Home Position 24 after changing the default
Home position from 0 to 24 without custom end points established
(for more information, see Step 7 on page 9)
INLET
NO FLO
W
(24 POSITION)
OUTLET
WATER FLOW
DIRECTION
WATER
FLOW
DIRECTION
Diverter Home position
“24” (Red LED on)
Press MODE button to toggle between:
AUTO Mode
(Green LED on):
The IntelliValve Valve
WARNING!
DO NOT mount the IntelliValve so that the SUCTION or return line of the
pump can be blocked. This will cause permanent pump damage.
Actuator is controlled automatically when connected to a
OFF Mode
(Red LED on):
Press SAVE button until AUTO LED is red.
SET Mode
(Blue LED on):
Mode changes to SERVICE (Yellow LED on). Press MODE, select AUTO.
Press or button to set endpoint
Press or button to set endpoint nearest to 24. Press SAVE.
SERVICE Mode
(Yellow LED on):
Use or to move valve diverter
position manually. Settings are not retained after exiting Service mode.
supported automation control system.
nearest to 0. Press SAVE.
+ to change Home position to opposite endpoint.
Diverter moves to Home position (Red LED on). If required, press