LOGIX SERIES INSTALLER
QUICK-START SHEET
Logix Series Controllers
See "Determining If You Have A 742 Or 762 Control" on page
20 to identify your controller.
742 Controller
- Electronic time clock control capable of doing
7-day (day ofweek) regeneration, or up to a 99 interval day
regeneration. This control will operate both in a conditioner
(softener) or filter mode with the same controller.
762 Controller
- Electronic metered-demand (volumetric)
controller which regenerates based on the water usage of the
installation site. A calendar override is a standard feature on
this controller.
The Logix Series will operate on both the 255 and Performa
valve body series.
Time & Day
Regen Time & Day
Salt
SU MO TU WE TH FR SA DAYS
LBS
PM
MIN
KG
x100
x2
P
H
C
Capacity
Hardness
LCD Display
DOWN Button
SET Button
UP Button
Manual
Regeneration
Initial Power-up
Initial Power Up - (CAMSHAFT proceeds to HOME position)
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
SU MO TU WE TH FR SA DAYS
• At initial power-up, the camshaft will need to rotate to
the HOME (in service) position.
• Camshaft may take 1-2 minutes to return to home position.
• Err 3 will be displayed until the camshaft returns to home.
• If more than 2 minutes elapses, verify that the motor
is turning the camshaft. If it is not turning, see the
troubleshooting section.
NOTE:
The Logix controller features a self-test sequence. At
first power-up of the control, you may see a number
such as 1.00, 1.02, 1.04, or 2.00, displayed. This is
an indication that the self-test is not completed. To
complete the test, verify that the turbine cable is
connected. Blow into the turbine port (valve outlet)
to spin the turbine. The controller will verify that the
turbine works and the self test will finish. Proceed
with the initial start up procedure.
Initial Start-up Step-by-step Instructions
Step 1: Select Valve Type
This step may have been performed by your system’s OEM
manufacturer. In this case, proceed to step 2.
• Identify your valve body type by looking at the silver ID
sticker on the back or side of the valve body.
• Select your valve body type using the UP or DOWN
buttons.
• Display Valve Body
255
255, conditioner
263
Performa filter 263, filter
268
Performa conditioner 268, conditioner
273
Performa Cv 273, filter
278
Performa Cv 278, conditioner
293
Magnum Cv filter, filter
298
Magnum Cv conditioner, conditioner
Step 2: Program System Size
Time & Day
Regen Time & Day
Salt
SU MO TU WE TH FR SA DAYS
Capacity
Hardness
Time & Day
Regen Time & Day
Salt
SU MO TU WE TH FR SA DAYS
Capacity
Hardness
This step may have been performed by your system’s OEM
manufacturer. In this case, proceed to step 3.
• Input system size - resin volume - in cubic feet or liters.
• Use UP and DOWN buttons to scroll through resin
volume choices.
• Choose the nearest volume to your actual system size.
• To choose a filter operation - press DOWN until an "F" is
displayed.
• Press SET to accept the system size you’ve selected.
• If incorrect setting is programmed, see "Resetting the
Control" section below.
Step 3: Program Time of Day
Time & Day
SU MO TU WE TH FR SA DAYS
Capacity
Hardness
• While "12:00" is blinking, set the correct time of day.
• Use the UP and DOWN buttons to scroll to the correct
time of day.
• "PM" is indicated, "AM" is not indicated.
• Press SET to accept the correct time of day and advance
to the next parameter.
AUTOTROL
742/762 Control 255 & Performa Series Valves (263, 268, 268FA) Service Manual
•
3
QUICK
ST
AR
T