background image

POSI-CLEAR™ RP Cartridge Filter Installation and User’s Guide

 

2

Filter Location

1.    The Posi-Clear™ RP Cartridge Filter should be mounted on a level 

concrete slab. 

Position the filter so that instructions, warnings and 

the pressure gauge are visible to the operator and readable

. It 

also should be positioned so that the piping connections, control valve 
and waste drain plug are convenient and accessible for servicing and 
winterizing.

2.   Be certain to install electrical controls (e.g., on/off switches, timers, 

control systems, etc.) so that the user is allowed enough space to stand 
clear of the filter and pump during startup, shutdown or servicing.

3.   Allow sufficient clearance around the filter to permit visual verification 

that the lock ring is properly installed around the tank flanges, see 

Figure 1

.

4.   Allow sufficient space above the filter to remove the filter lid for 

cleaning and servicing. This distance will vary with the model of 
filter you are using. See

 Table 2

 for the required vertical clearance.

5.  Position the filter to safely direct water drainage away from 

electrical equipment or anything that might be damaged. 

6.  Position the High Flow™ Manual Air Relief Valve to safely direct 

purged air or water.

Figure 1

INSTALLATION

RISK OF ELECTRICAL SHOCK OR ELECTROCUTION.

 Water discharged from an improperly positioned filter or 

valve can create an electrical hazard that can cause severe personal injury as well as damage property.

This filter must be installed by a qualified pool technician in accordance with all applicable local codes and 
ordinances. Improper installation could result in death or serious injury to pool users, installers, service persons, or 

others and may also cause damage to property.

Filter Plumbing

Make all plumbing connections in accordance with local plumbing and building codes.  Do not use pipe joint compound, 
glue or solvent on the bulkhead connections. The provided filter plumbing connections include an O-ring seal.

Use PTFE or silicone based lubricants when lubricating the O-rings on the union and bulkhead couplings. Use of 
petroleum based products will damage the equipment.

For Installation of Electrical Controls at Equipment Pad (ON/OFF Switches, Timers, Control Systems and 
Automation)

 Install all electrical controls at the equipment pad, such as ON/OFF switches, timers, control systems, 

etc. to allow the operation (startup, shutdown or servicing) of any pump or filter so the user does not place any 
portion of his/her body over or near the pump strainer lid, filter lid or valve closures. This installation should allow 
the user enough space to stand clear of the filter and pump strainer lid during system startup, shutdown or servicing 
of the system filter.

TABLE 2

  

 

Vertical 

  Model  

Size 

Clearance Req.

  160351 

100 sq. ft. 

61 in.

  160352 

150 sq. ft. 

76 in. 

 

  160350 

200 sq. ft. 

76 in.

Summary of Contents for 160350

Page 1: ...POSI CLEAR RP CARTRIDGE FILTER IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE...

Page 2: ...Instructions Maintenance Maintaining the Pressure Gauge Cleaning the Manual Air Relief Valve Cleaning the Filter Replacing Cartridge Element i 1 1 1 2 2 2 3 3 3 4 4 4 5 5 Troubleshooting Technical Da...

Page 3: ...e filter to separate and could cause severe personal injury or death if they were to strike a person This filter must be installed by a qualified pool serviceman in accordance with all applicable loca...

Page 4: ...pressure tests Pressures above 50 psi can damage your filter Be sure the maximum pressure of the filter system does not exceed the maximum pressure of any components within the system typically state...

Page 5: ...his filter will operate in a safe manner 2 The maximum working pressure of this filter is 50 psi Never subject this filter to pressure in excess of this amount even when conducting hydrostatic pressur...

Page 6: ...roperly positioned filter or valve can create an electrical hazard that can cause severe personal injury as well as damage property This filter must be installed by a qualified pool technician in acco...

Page 7: ...equires a quarter turn counterclockwise Opening this valve rapidly releases air trapped in the filter 2 Stand clear of the filter tank then start the pump 3 Close the manual air relief valve after a s...

Page 8: ...manual air relief valve by turning the valve cover assembly a quarter turn counter clockwise until it snaps into the full open position c Stand clear of the filter and wait until all pressure is relie...

Page 9: ...ris from inside the filter tank and from the O ring and O ring groove on the tank body 11 Replace clean cartridge element on support tube and install assembly into the filter tank body aligning the ar...

Page 10: ...owners are dismayed by the undesirable color and appearance of water in a newly filled pool Plaster dust can be responsible for short filter cycles requiring frequent cleaning 3 If pressure drops on...

Page 11: ...n plumbing size and other system components Flow Rates Residential Maximum Cartridge Flow Rates Commercial Maximum Cartridge Flow Rates Model Product sq ft GPM GPH 6 hour 8 hour GPM GPH 6 hour 8 hour...

Page 12: ...8 59053700 Center Core 100 sq ft Filter 9 59053800 Center Core 150 200 sq ft Filter 10 R173215 Cartridge Element 100 sq ft Filter 11 R173216 Cartridge Element 150 sq ft Filter 12 R173217 Cartridge El...

Page 13: ...NOTES...

Page 14: ...NOTES...

Page 15: ...NOTES...

Page 16: ...tries Unless expressly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and...

Reviews: