![background image](http://html1.mh-extra.com/html/pentair/160350/160350_installation-and-user-manual_1525080011.webp)
POSI-CLEAR™ RP Cartridge Filter Installation and User’s Guide
7
(1) Recommended flow rate for residential is 0.5 GPM per sq. ft.
(2) Commercial flow rate is a maximum of 0.375 GPM per sq. ft. of filter area.
NOTE: Actual system flow will depend on plumbing size and other system components.
Flow Rates
Residential
Maximum Cartridge
Flow Rates
Commercial
Maximum Cartridge
Flow Rates
Model #
Product # sq. ft.
GPM
GPH
6 hour
8 hour
GPM
GPH
6 hour
8 hour
PCRP
100
160351
100
100
6,000
36,000
48,000
38
2,280
13,680
18,240
PCRP
150
160352
150
150
9,000
54,000
72,000
56
3,360
20,160
26,880
PCRP
200
160350
200
150
9,000
54,000
72,000
75
4,500
27,000
36,000
Pressure Loss Chart
TECHNICAL DATA