UltraTemp
®
Heat Pump Installation and User’s Guide
43
The table below should be used by trained air-conditioning and refrigeration service people.
The table below
should not be used for adjusting the charge in the system.
Use of interpolation or extrapolation of the table data may not be appropriate unless it is closely matched
by the ambient and water fl ow conditions.
RH = Relative Humidity
Model
Discharge
Pressure (psig)
Suction Pressure
(psig)
Superheat
(F)
HP500
359
134
14
HP700
348
132
14
HP900
355
142
10
HP1200
367
141
8
HP1200R
367
141
8
UltraTemp 90
340
147
20
UltraTemp 110
343
164
11
UltraTemp 120
350
157
9
UltraTemp 120 H/C
378
157
10
UltraTemp 120C
354
150
12
UltraTemp 100I
340
154
10
UltraTemp 90I
354
157
9
Model
Discharge
Pressure (psig)
Suction Pressure
(psig)
Superheat
(F)
HP500
352
125
11
HP700
341
123
11
HP900
348
132
8
HP1200
360
131
6
HP1200R
360
131
6
UltraTemp 90
330
138
18
UltraTemp 110
337
153
9
UltraTemp 120
344
146
7
UltraTemp 120 H/C
368
146
8
UltraTemp 120C
346
146
10
UltraTemp 100I
335
144
8
UltraTemp 90I
335
152
8
Model
Discharge
Pressure (psig)
Suction Pressure
(psig)
Superheat
(F)
HP500
330
83
5
HP700
320
81
4
HP900
325
85
4
HP1200
322
86
3
HP1200R
322
86
3
UltraTemp 90
312
93
4
UltraTemp 110
324
92
4
UltraTemp 120
330
90
3
UltraTemp 120 H/C
336
90
3
UltraTemp 120C
318
89
4
UltraTemp 100I
329
86
4
UltraTemp 90I
327
90
4
Model
Discharge
Pressure (psig)
Suction Pressure
(psig)
Superheat
(F)
HP500
457
137
7
HP700
445
142
8
HP900
450
141
5
HP1200
478
135
6
HP1200R
478
135
6
UltraTemp 90
440
152
8
UltraTemp 110
453
159
5
UltraTemp 120
450
152
4
UltraTemp 120 H/C
474
152
4
UltraTemp 120C
450
150
7
UltraTemp 100I
452
151
4
UltraTemp 90I
473
150
6
Air: 80F, 80%RH Water: 80F, 45-50gpm
Air: 80F, 63%RH Water: 80F, 45-50gpm
Air: 50F, 63%RH Water: 80F, 45-50gpm
Air: 80F, 63%RH Water: 104F, 45-50gpm