background image

IMPORTANT SAFETY INSTRUCTIONS

2%!$!.$&/,,/7!,,).3425#4)/.3

SAVE THESE INSTRUCTIONS

Installation

and

User's Guide

SuperFlo

®

High Performance Pump

Summary of Contents for SuperFlo

Page 1: ...IMPORTANT SAFETY INSTRUCTIONS 2 7 3425 4 3 SAVE THESE INSTRUCTIONS Installation and User s Guide SuperFlo High Performance Pump ...

Page 2: ...TH ORP 5NLESS NOTED NAMES AND BRANDS OF OTHERS THAT MAY BE USED IN THIS DOCUMENT ARE NOT USED TO INDICATE AN AFlLIATION OR ENDORSEMENT BETWEEN THE PROPRIETORS OF THESE NAMES AND BRANDS AND 0ENTAIR 7ATER 0OOL AND 3PA NC 4HOSE NAMES AND BRANDS MAY BE THE TRADEMARKS OR REGISTERED TRADEMARKS OF THOSE PARTIES OR OTHERS P N 350096 Rev E 2 22 12 Customer Service F YOU HAVE QUESTIONS ABOUT ORDERING 0ENTAI...

Page 3: ...l Requirements 3 Wiring Installation 3 Section 3 Maintenance 5 Pump Strainer Basket 5 Cleaning the Pump Strainer Basket 5 Winterizing 7 Electric Motor Care 7 Section 4 Servicing 8 Pump Disassembly 8 Pump Reassembly Seal Replacement 9 Shaft Seal 9 Section 5 Restart Instructions 10 Priming the Pump 10 Section 6 Troubleshooting 11 Section 7 Technical Data 12 Illustrated Parts List 12 Pump Curves 13 ...

Page 4: ...ntative before using This pump is for use with permanent swimming pools and may also be used with hot tubs and spas if so marked Do not use with storable pools A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassem bled for storage and rea...

Page 5: ...AND KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Warnings and safety instructions for Pentair Water Pool and Spa pumps and other related products are available at http www pentairpool com pool owner safety warnings or call 800 831 7133 for additional free copies of these instructions Please refer to http www pentairpool com pool owner safety warnings for warning and safety instructions related to ...

Page 6: ...resent when the drain cover is missing broken loose cracked or not properly secured NOTE ALL SUCTION PLUMBING MUST BE INSTALLED IN ACCORDANCE WITH THE LATEST NATIONAL AND LOCAL CODES FOR SWIMMING POOLS SPAS AND HOT TUBS INCLUDING NSPI STANDARDS AND CPSC GUIDELINES TO MINIMIZE THE RISK OF INJURY DUE TO SUCTION ENTRAPMENT HAZARD Pools and spas should utilize a minimum of two drains per pump A proper...

Page 7: ...t down or servicing of any pump or filter so the user does not place any portion of his her body over or near the pump strainer lid filter lid or valve closures This installation should allow the user enough space to stand clear of the filter and pump during system start up shut down or servicing of the system filter For Installation of Electrical Controls at Equipment Pad ON OFF Switches Timers a...

Page 8: ...operly sized to the specific application and properly installed Pumps improperly sized or installed or used in applications other than for which the pump was intended can result in severe personal injury or death These risks may include but not be limited to electric shock fire flooding suction entrapment or severe injury or property damage caused by a structural failure of the pump or other syste...

Page 9: ...er feature or fountain And SuperFlo s silent running capability and small footprint allow it to easily drop into a compact equipment pad Efficient Quiet Rugged and Versatile All pumps from Pentair Water Pool and Spa incorporate innovative hydraulic engineering that has been refined for over 40 years SuperFlo reflects the latest and best Pentair technology to move water more efficiently for lower o...

Page 10: ...olute and pot reduce hydraulic noise See through lid permits easy inspection of strainer basket Additional Features 115 volt or 230 volt models available 1 2 Hp to 2 1 2 Hp configurations to accommodate a wide range of applications Self priming for quick easy start up Every SuperFlo pump is performance and pressure tested prior to shipment to ensure superior quality UL CUL NSF 2 SuperFlo Pump Inst...

Page 11: ...p Failure to do so could result in death or serious injury to serviceman pool users or others due to electric shock Wiring Installation 1 Be sure all electrical breakers and switches are turned off before wiring motor 2 Be sure that the wiring voltage matches the motor voltage 230 VAC or 115 VAC If they do not match the motor can overheat 3 Choose a wire size from the Chart 1 When in doubt use a h...

Page 12: ...ccessible wire connector on the motor to all metal parts of the swimming pool spa or hot tub structure and to all electrical equipment metal conduit and metal piping within 5 feet of the inside walls of the swimming pool spa or hot tub For Canada a 6 AWG or larger solid copper bonding conductor is required 9 The pump should be permanently connected to either a circuit breaker 2 pole timer or 2 pol...

Page 13: ...he pump may cause serious personal injury In order to avoid the possibility of personal injury make sure the suction and discharge valves are open and strainer pot temperature is cool to touch then open with extreme caution CAUTION To prevent damage to the pump and filter and for proper operation of the system clean pump strainer and skimmer baskets regularly 1 Turn off motor 2 Relieve pressure in...

Page 14: ...the system and become pressurized Pressurized air can cause the lid to separate which can result in severe injury death or property damage To avoid this potential hazard follow these instructions 11 Turn the power ON at the house circuit breaker Reset the pool time clock to the correct time 12 Open the manual air relief valve on top of the filter 13 Stand clear of the filter Start the pump 14 Blee...

Page 15: ...ure must be well ventilated to prevent overheating Provide ample cross ventilation 2 Protect against dirt Protect from any foreign matter or splashing water Do not store or spill pool chemicals near the motor Avoid sweeping or stirring up dust near the motor while in operation If a motor has been damaged by dirt it voids the motor warranty 3 Protect against moisture Protect from splashing pool wat...

Page 16: ...hed shaft seal faces seal will leak if faces are damaged Pump Disassembly 1 All moving parts are located in the rear sub assembly of this pump Required Tools 1 4 inch socket or open end wrench 3 8 inch socket or open end wrench 9 16 inch open end wrench Flat blade screwdriver 2 To remove and repair the motor sub assembly perform the following procedures a Turn off the pump circuit breaker at the m...

Page 17: ...al plate Make sure the plastic pins and holding screw inserts are aligned 7 Grease the diffuser quad ring and seal plate O ring prior to reassembly 8 Grease the bolt threads assemble the motor sub assembly to the strainer pot pump body by using the two through bolts for proper alignment Do not tighten the through bolts until all 4 bolts are in place and finger tightened 9 Fill the pump with water ...

Page 18: ...f pressure resulting in damage to the pump case impeller and seal and may cause property damage and personal injury Priming the Pump 1 The pump strainer pot must be filled with water before the pump is initially started Follow these steps to prime the pump a Remove the pump lid plastic clamp Remove the pump lid b Fill the pump strainer pot with water c Reassemble the pump cover and plastic clamp o...

Page 19: ...rom the volute Clean debris from impeller If debris cannot be removed complete the following steps 1 Remove left hand thread anti spin bolt and O ring 2 Remove clean and reinstall impeller 3 Reinstall anti spin bolt Reinstall diffuser and quad ring Reinstall motor and seal plate into volute Reinstall clamp around seal plate and volute and tighten securely Pump strainer clogged Clean suction trap S...

Page 20: ...W 16 X 2 HEX HD 4 req 13 072184 WASHER 3 8 in S S 4 req 14 355619 O RING SEAL BRACKET 15 350099 O RING ADAPTER 2 226 2 req 16 355030 SEAL DIFFUSER 17 355334 SCREW 8 32 HEX WASHER HD 3 req 18 355617 DIFFUSER HP 18 355617 DIFFUSER HP 18 355617 DIFFUSER 1 HP 18 355618 DIFFUSER 1 HP 18 355618 DIFFUSER 2 HP 18 350170 DIFFUSER 2 HP 19 354290 HEX HEAD SCREW 3 8 16 4 req 20 355043 IMPELLER HP 20 355043 IM...

Page 21: ...ump Installation and User s Guide 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Total Dynamic Head In Feet Of Water Flow Rate in U S GPM Pentair Water Pool and Spa Inc Pump Performance Curve SuperFlo Series HP 1 HP 1 HP 2HP HP 1 HP 1 HP 2 HP 3450 RPM 2 HP 1750 RPM ...

Page 22: ...NOTES 14 SuperFlo Pump Installation and User s Guide ...

Page 23: ...SAVE THESE INSTRUCTIONS ...

Page 24: ...P N 350096 Rev E 2 22 12 350096 LIT PKG P N 354707 354707 ...

Reviews: