Model RO-2600
5 Stage Reverse Osmosis System With Pump
Installation and Operation Manual
145600 Rev
E
SE11
OPERATING SPECIFICATIONS
WARNING:
Before installing the system, make certain
your water supply complies with the
following operating specifications. Failure
to do so may reduce the effectiveness of the
system and will void the warranty. Consult
your local water treatment utility or a certified
water testing lab to determine the quality for
your water and use the table below to record
your results for future reference.
RO-2600 Specifications
Thin Film Membrane:
TLC 75
Pressure Range:
1.4–6.9 bar
Temperature Range:
4.4-37.7°C
Total Dissolved Solids
2000 ppm
Maximum Hardness
†
:
10 gpg (171 mg/L)
Sulfide, Iron and Manganese
‡
:
0 ppm < 0.1 ppm
Chlorine in Water Supply:
Less than 2 ppm
pH Limits:
3–11
Daily Product Water Rate*:
227 Lpd
TDS Rejection:
90% @ 2 bar inlet
Turbidity:
5 NTU Max
†
If the hardness of your water is above 10 gpg (171 mg/L), lime scale will build
up rapidly on the membrane inside of the RO membrane cartridge. Scale
buildup will plug the RO membrane cartridge and make the system ineffective.
We do not recommend the reverse osmosis system to be used with water in
excess of 10 gpg (171 mg/L) hardness.
‡
A maximum total level of approximately 0.01 ppm sulfide, iron or manganese is
permissible. See your local dealer to reduce these substances in your water.
*Based on manufacturer's internal testing.
RO-2600 Dimensions:
Overall Dimensions
45.7 x 20.3 x 45.7 cm
Tank Dimensions
34.3 x 27.9 cm
Weight
10.4 kg
Tank Capacity Max.
1
6.5
L
Tank Air Pressure Empty 0.34 to 0.48 bar
Tank Weight Full
12.9 kg
Tools Required
•
Hand or electric drill
•
Slotted and phillips
screwdrivers
• 2 Adjustable wrenches
• Drill bits: 1/8", 1/4" and 3/8"
•
File
• Safety glasses
Optional Materials
(For sinks without extra hole for faucet)
•
Center punch
• 1⅜ inch hole saw or drill bit
•
Cone-shaped grinding
wheel
• Safety mask
NOTE: All tools listed will not be necessary for installation.
Read installation procedures before starting to
determine required tools.
Parts Included (See back of manual for diagram)
• Pre-assembled filter system (mounting bracket, membrane
housing, prefilter housings, pre- and postfilter cartridges,
booster pump, transformer, high and low pressure
switches, solenoid valve).
• RO membrane
• Installation Kit
• Storage Tank