MYERS LIMITED WARRANTY

During the time periods and subject to the conditions hereinafter set forth, F.E. Myers will repair or replace to the original user or consumer any portion of your
new MYERS product which proves defective due to defective 
materials or workmanship of MYERS.  Contact your nearest Authorized MYERS Dealer for warranty service. At all times MYERS shall have and possess the sole
right  and option to determine whether to repair or replace defective equipment, parts, or components. Damage due to lightning or conditions beyond the con-
trol of MYERS is NOT COVERED BY THIS WARRANTY. 

WARRANTY PERIOD 

Pumps: 12 months from date of installation or 18 months from date of manufacture. 
Tanks: 5 years from date of purchase.
Labor, etc. Costs: MYERS shall IN NO EVENT be responsible or liable for the cost of field labor or other charges incurred by any customer in removing and/or
re-affixing any MYERS product, part or component thereof. 
THIS WARRANTY WILL NOT APPLY: (a) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with
printed instructions provided; (b) to failures resulting from abuse, accident or negligence; (c) to normal maintenance services and the parts used in connection
with such service; (d) to units which are not installed in accordance with applicable local codes, ordinances and good trade practices; or (e) unit is used for pur-
poses other than for what it was designed and manufactured, and (f) if three-phase submersible motors are installed on a single-phase power supply using a
phase converter or if three-phase power is supplied by only two transformers, making an open Delta system. 
RETURN OR REPLACED COMPONENTS: Any item to be replaced under this Warranty must be returned to MYERS in Ashland, Ohio, or such other place as
MYERS may designate, freight prepaid. 
PRODUCT IMPROVEMENTS: MYERS reserves the right to change or improve its products or any portions thereof without being obligated to provide such a
change or improvement for units sold and/or shipped prior to such a change or improvement. 
WARRANTY EXCLUSIONS: MYERS SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR-
POSE AFTER THE TERMINATION OF THE WARRANTY PERIOD SET FORTH HEREIN. 
Some states do not permit some or all of the above warranty limitations and, therefore, such limitations may not apply to you.  No warranties or representations
at any time made by any representative of MYERS shall vary or expand the provisions hereof. 
LIABILITY LIMITATION: IN NO EVENT SHALL MYERS BE LIABLE OR RESPONSIBLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULT-
ING FROM OR RELATED IN ANY MANNER TO ANY MYERS PRODUCT OR PARTS THEREOF. PERSONAL INJURY AND/OR PROPERTY DAMAGE MAY
RESULT FROM IMPROPER INSTALLATION. MYERS DISCLAIMS ALL LIABILITY, INCLUDING LIABILITY UNDER THIS 
WARRANTY, FOR IMPROPER INSTALLATION–MYERS RECOMMENDS FOLLOWING THE INSTRUCTIONS IN THE INSTALLATION MANUAL. WHEN IN
DOUBT, CONSULT  A PROFESSIONAL. 
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. 
This Warranty gives you specific legal rights and you may also have other rights which vary from state to state. 
In the absence of suitable proof of the purchase date, the effective date of this Warranty will be based upon the date of manufacture. 
DETERMINATION OF UNIT DATE OF MANUFACTURE: Submersible Sump Pump (8-95) month and year stamped on pump nameplate; Column Sump Pump
month and year on red warranty tag.

MYERS

1101 Myers Parkway, Ashland, Ohio 44805-1989

Phone: 419-289-1144 • Fax: 419-289-6658 • www.femyers.com

Summary of Contents for Myers DE Series

Page 1: ...s 2005 253P7090 3 21 05 1101 Myers Parkway Ashland OH 44805 Phone 1 419 289 1144 Fax 1 419 289 6658 Web Site http www myerspump com 4935 0405 DE and DS Series Installation Operation Parts For further operating installation or maintenance assistance Call 1 419 289 1144 ...

Page 2: ...azards that can cause serious personal injury death or major property damage if ignored Warns about hazards that will or can cause minor personal injury or property damage if ignored NOTE Indicates special instructions which are important but not related to hazards NOTE Pump must be installed in a vertical position only Installing pump in any other position will void warranty To avoid serious inju...

Page 3: ... pump E Three phase pumps are intended for permanent con nection only Provide strain relief at control box for power supply cord connection to box All control components must be UL listed and suitable for end use application Only qualified personnel should install the pump and associated control equipment INSTALLATION Risk of electrical shock Can burn or kill Do not lift pump by power cord See Lif...

Page 4: ...ed grounding type recep tacle only Connect pump according to all applicable codes For automatic operation plug or wire pump into an auto matic float switch or pump controller For continuous operation plug directly into an electrical outlet or wire directly into switch box Connect pump to its own individ ual branch circuit with nothing else on the circuit For fuse circuit breaker requirements see S...

Page 5: ... seal from the pump shaft 7 Remove the rotor shaft assembly from the pump body 8 Carefully tap the shaft out of the seal plate DE40PC1 and DE50PC1 or pump body DSW40P1 through DSW100M4 9 Remove the stationary half of the mechanical seal from the seal plate DE40PC1 and DE50PC1 or pump body DSW40P1 through DSW100M4 10 Slide the lower bearing holder off of the shaft and pop the oil seal out of the lo...

Page 6: ...Repair Parts 6 1 2 3 4 5 6 7A 8 13 9 11 10 7B 14 7D 15 16 17 18 7E 19 20 21 22 7F 23 11 7C 12 ...

Page 7: ...embly 1 ZBR017120 ZBR017120 10 Seal ring oil seal 111P1460 111P1460 11 Nut M5 SS 6 12 Brass nut M22 1 171P4230 171P4230 13 Capscrew M4x6 SS 1 14 Seal plate 1 784S0720 784S0720 15 Oil plug gasket 1 111P0990 111P0990 16 Oil plug 1 121P2100 121P2100 17 Mechanical seal complete 1 ZBR0030 ZBR0030 18 Washer 1 784S1180 784S1180 19 Impeller 1 731S7170 731S3150 20 Washer 1 171P1720 171P1720 21 Self locking...

Page 8: ...Repair Parts 8 1 2 3 4 5 6 7A 8 13 9 11 10 7B 16 15 14 19 17 18 20 7D 21 22 23 24 25 11 7C 7E 12 ...

Page 9: ...30 171P4230 13 Capscrew M4x6 SS 1 14 Capscrew M5x10 SS 1 15 Pump body 1 723S3390 723S3390 723S3390 16 Capscrew M5x70 SS 3 17 Oil plug gasket 1 111P0990 111P0990 111P0990 18 Oil plug 1 121P4230 121P4230 121P4230 19 Mechanical seal complete 1 1111P2720 111P2720 111P2720 20 Washer 1 784S1180 784S1180 784S1180 21 Impeller 1 187P0190 731S7210 731S7210 22 Washer 1 171P1720 171P1720 171P1720 23 Self Lock...

Page 10: ...Repair Parts 10 1 2 3 4 5 6 7A 8 13 9 11 10 7B 16 15 14 19 17 18 20 7D 21 22 23 24 25 11 7C 7E 12 ...

Page 11: ...1P4230 171P4230 13 Capscrew M4x6 SS 1 14 Capscrew M5x10 SS 1 15 Pump body 1 723S3390 723S3390 16 Capscrew M5x70 SS 3 17 Oil plug gasket 1 111P0990 111P0990 18 Oil Plug 1 121P4230 121P4230 19 Mechanical seal complete 1 111P2720 111P2720 20 Washer 1 784S1180 784S1180 21 Impeller 1 731S7190 731S7190 22 Washer 1 171P1720 171P1720 23 Self Locking Nut M8 1 121P2780 121P2780 24 Diffuser 1 731P0820 731P08...

Page 12: ...o allow motor to cool then reconnect to power source Check for cause of overheating Pump fails to 1 All valves in discharge pipe are 1 Check to be sure all valves in discharge pipe are empty sump not fully open fully open 2 Discharge pipe and check valve 2 Clean out discharge pipe and check valve are clogged 3 Pump inlet or impeller have 3 Check for blockage in pump inlet or impeller blockage and ...

Page 13: ...this Warranty must be returned to MYERS in Ashland Ohio or such other place as MYERS may designate freight prepaid PRODUCT IMPROVEMENTS MYERS reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for units sold and or shipped prior to such a change or improvement WARRANTY EXCLUSIONS MYERS SPECIFICALLY DISCLAIMS ...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...16 ...

Reviews: