IntelliBrite
®
5g Pool LED Light Installation and User’s Guide
9.
Leave at least four (4) feet of cord to coil around the new IntelliBrite
light fixture (see Figure 1 on page 7). This four (4) feet of cord coiled
around the light allows the light to be serviced.
10. Install the IntelliBrite 5g light assembly into the niche in the pool.
11. Install the special bronze pilot screw at the top of face ring to secure
the light to the niche.
12.
Final check for proper IntelliBrite light operation:
Switch on the
main switch or circuit breaker to the system, and the switch that
operates the IntelliBrite underwater light itself. The light should
illuminate when power is applied. If not recheck the installation steps
starting with Step 1 (page 10).
1.
Turn off main electrical switch or circuit breaker
, as well as the switch
which operates the IntelliBrite 5g pool LED underwater light itself.
2.
Before starting make sure that you have a new lens gasket (P/N 79101600)
and a IntelliBrite 5g pool LED light assembly (P/N 619818Z) ready to install.
Replace the light assembly with the same type and wattage.
Failure to replace the light assembly with the same type will
damage the LED light assembly and may cause an electrical hazard resulting in
death or serious injury to pool users, installers, or others due to electrical shock,
and may also cause damage to property.
Removal and Installation
D A N G E R !
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
Always disconnect power to the pool light at the circuit
breaker before servicing the light. Failure to do so could
result in death or serious injury to installer, serviceman, pool
users, or others due to electrical shock.
When replacing or reassembling the IntelliBrite 5g Pool Light,
the Gasket (P/N 79101600) or Gasket and Lens (619864) MUST
ALSO BE REPLACED - SEE PAGE 17 FOR PART NUMBERS
REPLACING THE INTELLIBRITE 5G POOL LED CIRCUIT BOARD
(IN AN EXISTING POOL)
11
Always install a new lens gasket (P/N 79101600) whenever
disassembling the IntelliBrite 5g light assembly. Failure to do so
may permit water to leak into the assembly which could cause:
(a)
an electrical hazard resulting in death or serious injury to pool users,
installers, or others due to electrical shock, or
(b)
breakage of the lens, which likewise could result in serious injury to pool
users, installers, or bystanders, or in damage to property.