5

4. If pump is using the series cord

plug, the two plugs may not be
plugged tight together.

5. Float may be stuck. Be sure

float operates freely in basin.

6. If all symptoms check OK,

motor winding may be 
open; take to service center 
for check.

Pump runs but does not 
deliver water.

1. Check valve may be installed

backward. Arrow in valve
points in direction of flow.

2. Discharge gate valve, if used,

may be closed.

3. Pump may be air locked. Start

and stop several times by
plugging and unplugging cord.
Check vent hole in pump case
for plugging.

4. Pump head may be too high.

Pump cannot deliver water
over 30' (

1

2

HP), 26' (

1

3

HP)

vertical. Horizontal distance
does not affect pumping,
except loss due to friction.

5. Inlet in pump base may be

clogged.  Remove pump and
clean out openings.

6. Impeller or volute openings

may be plugged or 
partially plugged.  Remove
pump and clean per 
maintenance instructions.

Pump runs and pumps out
sump but does not stop.

1. Float is stuck in Up position.

Be sure float operates freely 
in basin.

Pump runs but delivers only
small amount of water.

1. Pump may be air locked.  Start

and stop several times by
plugging and unplugging cord.

Check vent hole in pump case
for plugging.

2. Pump head may be too high.

Pump cannot deliver water
over 30' (

1

2

HP), 26' (

1

3

HP)

vertical. Horizontal distance
does not affect pumping,
except loss due to friction.

3. Inlet in pump base may be

clogged.  Remove pump and
clean out openings.

4. Impeller or volute openings

may be plugged or partially
plugged. Remove pump and
clean per maintenance
instructions.

5. Pump impeller may be 

partially clogged causing
motor to run slow, resulting in
motor overload. Clear impeller.

Fuse blows or circuit breaker
trips when pump starts.

1. Inlet in pump base may be

clogged.  Remove pump and
clean out openings.

2. Impeller or volute openings

may be plugged or 
partially plugged.  Remove
pump and clean per 
maintenance instructions.

3. Pump impeller may be 

partially clogged causing
motor to run slow, resulting 
in motor overload. Clear
impeller.

4. Fuse size or circuit breaker is

too small.

5. Defective motor stator: return

to Hydromatic service center
for verification.

Motor runs for short time then
stops. Then after

short 

period starts again. Indicates
tripping overload caused by
symptom shown.

1. Inlet in pump base may be

clogged.  Remove pump and
clean out openings.

2. Impeller or volute openings

may be plugged or 
partially plugged.  Remove
pump and clean per 
maintenance instructions.

3. Pump impeller may be 

partially clogged causing
motor to run slow, resulting in
motor overload. Clear impeller.

4. Defective motor stator: return

to Hydromatic service center
for verification.

Your pump warranty is void…

If…

power cord has been cut or

spliced.

If…

pump has been used to pump

mud, cement, tar, abrasives or
chemicals.

If…

pump has been used for

pumping of hot water (above
120°F).

If…

pump has been dismantled

by other than authorized
Hydromatic service center or
distributor.

Summary of Contents for Hydromatic SW33

Page 1: ...ffluent Pumps SW33 SD33 New 1 2HP Models SW SD VS50 VS33 NOTE To the installer Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains...

Page 2: ...then 1 provide proper safety precautions per OSHA requirements and 2 do not enter sump until these precautions are strictly adhered to Do not install pump in location classified as hazardous per N E...

Page 3: ...9 Use pump submerged for pumping waterlike liquids temperature to 120 F WARNING Risk of Electrical Shock This pump has not been investigated for use in swimming pool areas 10 CAUTION Do not pump flamm...

Page 4: ...tripped circuit breaker or a power cord not completely inserted into the receptacle 3 NOTE Automatic thermal overload protects the sealed in oil motor Running dry will overheat the motor and activate...

Page 5: ...mp base may be clogged Remove pump and clean out openings 4 Impeller or volute openings may be plugged or partially plugged Remove pump and clean per maintenance instructions 5 Pump impeller may be pa...

Page 6: ...6 SW SD VS33 50 Parts List...

Page 7: ...FIBER 1 2 HP ONLY 14828 000 1 1 15 CASE VOLUTE 1 3 HP 8504 002 2 1 CASE VOLUTE 1 2 HP 8504 005 2 1 16 SEAL SHAFT ROT 21607A001 1 18 SEAL RING 149 001 1 1 19 STATOR 1 3 HP 14590 001 1 1 STATOR 1 2 HP...

Page 8: ...and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if receive...

Reviews: