background image

7

be used to ease its removal.
This kit will include a pusher
to reassemble in re 

place 

ment

of flame ring.

6.  Set seal housing in upright 

po si tion and bump end of shaft
on hard wood block. This will
push the bearing from the
housing and will force upper
seal from shaft.

7.  Use bearing puller to remove

bear 

ings. Replace with new

bear 

ings. Press only on inner

face of bearing when replacing.
Pressing on outer face can
damage the bear  ing. Bearings
are stan 

dard size that can be

obtained from any bearing 

sup ply house or can be obtained
from Hydromatic factory.

8.  

IMPORTANT: 

Do not use

any of the old seal parts.
Replace with all new seals.

NOTE: Any time seal is 
disturbed, replace seal.

9.  Thoroughly clean all castings

be fore  re plac ing  seals.  One
grain of dirt between the seal
faces can cause failure.

10.Examine all O-rings for nicks

be fore  re us ing.

11.Use Locktite (red) on socket

head locking screw in end of
shaft.

12.Before refilling chamber with

oil, air test as described in
replacing stator.

13.Refill both chambers with oil,

as described in replacing stator.

14.Always check all leads with

high voltage or with Megger
for grounds before operating
the pump.

15.Check pump for proper 

rotation before re 

turn 

ing to

normal ser vice.

Pump
Notes

______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________

Summary of Contents for Hydromatic H3HX Series

Page 1: ...D FM 06 10 Item E 03 487 Part 5625 487 1 NOTE To the installer Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system Installation...

Page 2: ...hazardous location submersible pumps have two factory installed moisture detectors seal failure probes They are in a normally open series circuit in the seal chamber Under normal operating conditions...

Page 3: ...A When using single phase pumps make sure red pump lead is connected to capacitor circuit connect amprobe to pump power cord and turn pump on Pump will show high amp draw momentarily then as pump come...

Page 4: ...RED 330K D C GREEN HEAT SENSORS 120 VAC 5A SEAL PROBES 300 VAC 20 MA POWER CORD CONTROL CORD SEE TYPICAL CONTROL CIRCUITRY BELOW CRS RUN CAPACITOR CRS START CAPACITOR CAPACITOR PACK PANEL M RUN LIGHT...

Page 5: ...could enter panel and an explosive condition could exist Pump cords may be disconnected at pump by removing the cord and cap assembly unplugging sensor wires and removing wire nuts After removal from...

Page 6: ...O ring seal has been replaced If O ring is nicked or cut replace with new ring This applies to all O rings used in assembly 11 After all leads are reconnected in the connection box make a high voltage...

Page 7: ...Locktite red on socket head locking screw in end of shaft 12 Before refilling chamber with oil air test as described in replacing stator 13 Refill both chambers with oil as described in replacing stat...

Page 8: ...art No No Description Qty Ref Part Part No No Description Qty PUMP PUMP V RPM Connection Rotor Stator Connector box Spacer Connector Connector DESCRIPTION PART HP Box B1 Shaft Assy B2 B3 to cord cap B...

Page 9: ...9 H3HX...

Page 10: ...perly install operate or maintain the unit in accordance with the printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and parts use...

Page 11: ......

Page 12: ...Line Voltage _________________________________Actual ___________________________________ Voltage to Pumps _____________________________________Actual ___________________________________ Type of Junct...

Reviews: