37
2009 AT8 M anual
Use the UP arrow to scroll from the oldest to the newest record and dOWN arrow to scroll from
the newest to the oldest.
• FORMAT
TOP lINE: # mmddYY HH:mm C
# = unit number for this record.
mm = month, dd = day, YY = Year, date for record.
HH = hour, mm = minute, time of record.
C = appears if a configuration change occurred.
bOTTOm lINE: FOPT ORP pH Temp
F = appears if there was flow.
O = appears if there was an ORP alarm.
P = appears if there was a pH alarm.
T = appears if there was a Temperature alarm.
ORP = the ORP reading.
pH = the pH reading.
Temp = the temperature reading.
• When you reach the end of the log you will go on to the next screen.
• Press – SELECT to go on or
press mENU to return to reading screen.
5.6.3 log Contents
• Use the up and down arrows to select either “yes” or “no”.
YES will clear all data from the log when you press SElECT.
• Press – SELECT or
press mENU to return to reading screen.
• If the data log is not reset, the data will continue to write over the existing data, oldest
entry first.
5.6.4
Reset data log
This allows viewing of the stored data.
LOG CONTENTS
ARROWS TO REVIEW
RESET LOG
NO