ENGLISH
WARNING!
After an automatic cut-out via the temperature limiters, the
cause of the malfunction must first be eliminated. Only then
may the motor be switched on again manually.
The restart interlock must be "non-resetting on power failure",
i.e. the lock must be in place to prevent restarting even after a
power cut (in Europe: Directive 2014/34/EU , Appendix II 1.5, EN
60079-17 Table1, B10).
Operation with frequency converter
Frequency converters may only be used for controlling the fre-
quency of special models of three-phase pumps.
NOTICE!
For physical reasons, pumps may not be operated at
a higher frequency than that shown on the type plate. If the
frequency increases beyond the value on the type plate, the
power input increases and the motor is then overloaded.
For special models of three-phase pumps that are designed for
frequency converter operation, the motor type shown on the
type plate is labelled with an additional "K" (e.g. D90-2/75 CK).
These pumps also have a sticker on the end of the cable that
indicates their suitability for use with a frequency converter.
These motors are fitted with PTC thermistors as winding pro
-
tectors. Voltages of more than 2.5 V may not be connected to
the winding protection terminals 40 and 41! For explosion pro-
tected pumps, a type-tested tripping unit that complies with
the EU type-testing requirements is also necessary.
Rotational direction
The rotational direction must be checked before installation! If
the rotational direction is correct, the start-up jolt should be in
the opposite direction to the rotational direction arrow on the
motor housing. The wrong rotational direction is also indicated
if the pump performs inadequately when installed, or if loud
noises can be heard during operation. If the rotational direc-
tion is wrong, 2 phases of the supply cable must be swapped
over.
CAUTION!
The start-up jolt can be very forceful.
Potential equalisation
To comply with EN 60079-14 and EN 1127-1, an additional equi-
potential bonding must be installed for facilities with protec-
tive earth conductors in TN/TT networks in areas subject to
explosion hazards. In Germany, for example, the design must
be in accordance with VDE 0100, Part 540 (Association of Ger-
man Electrical Engineers).
No additional potential equalisation is required on site for
JUNG PUMPEN concrete or plastic chambers in explosion
zones 1 and 2 (statement made by TÜV Nord (Technical Inspec-
tion Agency) in March 2008).
Exception: if conductive parts, such as cable protection
sleeves made of corrugated pipe or a pressure pipe made of
metal, are connected to the chamber from the outside. In this
case, an electrically conductive connection must be made be-
tween the conductive parts and the housing of the pump(s).
For corrosion protection reasons, the connection should be
made using stainless steel.
Explosion protected pumps have a special connection point at
the cable entry point.
INSTALLATION
ATTENTION!
Before the pump can be installed, the 4 plastic
packaging feet must be unscrewed from the bottom of the
pump housing and removed.
The pump must be installed as shown in the examples. For in-
stallations in accordance with EN 12056-4, the pressure pipe
must be laid in a loop above the local back pressure level and
protected with a back pressure prevention valve.
Example installation
with guide rail system
Assembly:
Fix the coupling base firmly to the floor of the col
-
lection chamber using plugs and then mount the guide rails.
Next, install the pressure pipe including the necessary fittings,
such as the non-return valve and shut-off valves.
Finally, fit the pump with the screwed-on coupling catch on to
the guide rails and lower it into place using a chain fixed to the
shackle.
A fixing facility for lifting gear should be provided above the
chamber opening at a sufficient height.
Level monitoring can be carried out using various systems.
Their specific characteristics and requirements can be found
in the relevant operating manuals.
WARNING!
In accordance with the explosion protection laws and regula-
tions, JUNG Ex-pumps should never be allowed to run dry or to
operate in "snore" mode.
The pump must switch off when the water level sinks to the
upper edge of the pump housing (x in the illustration), at the
very latest. This shut-down must be implemented via a sepa-
rate switching circuit. Dry running for servicing or inspection
purposes may only take place outside the potentially explosive
area.
A correspondingly larger diameter pipe should be used for
longer pressure pipelines to avoid pipe friction losses.
Rising pressure pipes must be protected from frost! A cham-
ber cover must be selected that is suitable for the intended use
and has the required load-bearing capacity.
If necessary, the pump housing can be ventilated by unscrew-
ing the "Luft" sealing screw. A flushing pipe, available as an ac
-
cessory, can be installed to minimise deposits and the forma-
tion of floating layers in the chamber.
If the pump is malfunctioning, part of the contents of the oil
reservoir could escape into the pumping medium.
Not Ex-pumps.
If a hose is used as a pressure line, care must
be taken to ensure that for every pumping operation the hose
is completely empty before the pump is submersed. Any resid-
ual liquid would obstruct the ventilation of the pump housing
and therefore also hinder the pumping operation.
5
Summary of Contents for Multistream 10/2 A1
Page 12: ...12...
Page 13: ...13...
Page 14: ...14...
Page 15: ...15...
Page 16: ...16...
Page 17: ...17...
Page 18: ...18...
Page 19: ...19...
Page 20: ...20...
Page 21: ......
Page 24: ...2...
Page 34: ...12...
Page 35: ...13...
Page 36: ...14...
Page 37: ...15...
Page 38: ...16...
Page 39: ...17...
Page 40: ...18...
Page 41: ...19...
Page 42: ...20...
Page 48: ...2...
Page 57: ...11...
Page 58: ...12...
Page 59: ...13...
Page 60: ...14...
Page 61: ...15...
Page 62: ...16...
Page 63: ...17...
Page 64: ...18...