background image

13

  

E-03-558 (07-05-20)

IMPELLER PARTS LIST

S6A(X)P

CAT. NO.

HP

VOLT/PH

CORD

TRIM

IMPELLER

  1750 RPM

S6A(X)P2500DC

25

208/3

4-4

9

136940132

S6A(X)P2500EC

25

230/3

6-4

9

136940132

S6A(X)P2500FC

25

460/3

8-4

9

136940132

S6A(X)P2500GC

25

575/3

8-4

9

136940132

S6A(X)P3000EC

30

230/3

4-4

9.5

136940112

S6A(X)P3000FC

30

460/3

8-4

9.5

136940112

S6A(X)P3000GC

30

575/3

8-4

9.5

136940112

S6A(X)P4000FC

40

460/3

6-4

10.5

136940072

S6A(X)P4000GC

40

575/3

8-4

10.5

136940072

  1150 RPM

S6A(X)P750DB

7.5

208/3

8-4

9

136940132

S6A(X)P750EB

7.5

230/3

8-4

9

136940132

S6A(X)P750FB

7.5

460/3

10-4

9

136940132

S6A(X)P750GB

7.5

575/3

10-4

9

136940132

S6A(X)P1000DB

10

208/3

8-4

10

136940102

S6A(X)P1000EB

10

230/3

8-4

10

136940102

S6A(X)P1000FB

10

460/3

10-4

10

136940102

S6A(X)P1000GB

10

575/3

10-4

10

136940102

S6A(X)P1500DB

15

208/3

8-4

11

136940052

S6A(X)P1500EB

15

230/3

8-4

11

136940052

S6A(X)P1500FB

15

460/3

8-4

11

136940052

S6A(X)P1500GB

15

575/3

10-4

11

136940052

  870 RPM

S6A(X)P500DA

5

208/3

8-4

9.5

136940112

S6A(X)P500EA

5

230/3

10-4

9.5

136940112

S6A(X)P500FA

5

460/3

10-4

9.5

136940112

S6A(X)P500GA

5

575/3

10-4

9.5

136940112

S6A(X)P750DA

7.5

208/3

8-4

10

136940102

S6A(X)P750EA

7.5

230/3

8-4

10

136940102

S6A(X)P750FA

7.5

460/3

10-4

10

136940102

S6A(X)P750GA

7.5

575/3

10-4

10

136940102

S8F(X)P

Cat. No.

HP

Volt/Ph

Cord

Trim

Impeller

  1750 RPM

S8F(X)P2000DC

20

208/3

6-4

9.63

025940302

S8F(X)P2000EC

20

230/3

6-4

9.63

025940302

S8F(X)P2000FC

20

460/3

8-4

9.63

025940302

S8F(X)P2000GC

20

575/3

8-4

9.63

025940302

S8F(X)P2500DC

25

208/3

4-4

10.13

025940172

S8F(X)P2500EC

25

230/3

6-4

10.13

025940172

S8F(X)P2500FC

25

460/3

8-4

10.13

025940172

S8F(X)P2500GC

25

575/3

8-4

10.13

025940172

S8F(X)P3000EC

30

230/3

4-4

10.5

025940082

S8F(X)P3000FC

30

460/3

8-4

10.5

025940082

S8F(X)P3000GC

30

575/3

8-4

10.5

025940082

S8F(X)P4000FC

40

460/3

6-4

11.38

025940202

S8F(X)P4000GC

40

575/3

8-4

11.38

025940202

  1150 RPM

S8F(X)P750DB

7.5

208/3

8-4

10.38

025940162

S8F(X)P750EB

7.5

230/3

8-4

10.38

025940162

S8F(X)P750FB

7.5

460/3

10-4

10.38

025940162

S8F(X)P750GB

7.5

575/3

10-4

10.38

025940162

S8F(X)P1000DB

10

208/3

8-4

10.88

025940272

S8F(X)P1000EB

10

230/3

8-4

10.88

025940272

S8F(X)P1000FB

10

460/3

10-4

10.88

025940272

S8F(X)P1000GB

10

575/3

10-4

10.88

025940272

S8F(X)P1500DB

15

208/3

8-4

11.5

025940122

S8F(X)P1500EB

15

230/3

8-4

11.5

025940122

S8F(X)P1500FB

15

460/3

8-4

11.5

025940122

S8F(X)P1500GB

15

575/3

10-4

11.5

025940122

  870 RPM

S8F(X)P500DA

5

208/3

8-4

11.25

025940112

S8F(X)P500EA

5

230/3

10-4

11.25

025940112

S8F(X)P500FA

5

460/3

10-4

11.25

025940112

S8F(X)P500GA

5

575/3

10-4

11.25

025940112

S8F(X)P750DA

7.5

208/3

8-4

11.88

025940002

S8F(X)P750EA

7.5

230/3

8-4

11.88

025940002

S8F(X)P750FA

7.5

460/3

10-4

11.88

025940002

S8F(X)P750GA

7.5

575/3

10-4

11.88

025940002

C4H(X)P

CAT. NO.

HP

VOLT/PH

CORD

TRIM

IMPELLER

  1750 RPM

C4H(X)P2000DC

20

208/3

6-4

9

153590232

C4H(X)P2000EC

20

230/3

6-4

9

153590232

C4H(X)P2000FC

20

460/3

8-4

9

153590232

C4H(X)P2000GC

20

575/3

8-4

9

153590232

C4H(X)P2000DC

25

208/3

4-4

9.5

153590192

C4H(X)P2000EC

25

230/3

6-4

9.5

153590192

C4H(X)P2000FC

25

460/3

8-4

9.5

153590192

C4H(X)P2000GC

25

575/3

8-4

9.5

153590192

C4H(X)P2000EC

30

230/3

4-4

10.5

153590112

C4H(X)P2000FC

30

460/3

8-4

10.5

153590112

C4H(X)P2000GC

30

575/3

8-4

10.5

153590112

C4H(X)P2000FC

40

460/3

6-4

11.88

153590002

C4H(X)P2000GC

40

575/3

8-4

11.88

153590002

250 Frame Pumps Impeller Parts List

Summary of Contents for C4H(X)P

Page 1: ...t 056255581 2020 All Rights Reserved INSTALLATIONAND OPERATIONMANUAL SUBMERSIBLE SOLIDSHANDLING PUMP C4H X P H4Q X P S4K X P S4L X P S4LV X P S4B X P S6L X P S6A X P S8F X P Used in hazardous locations Class I Division I Groups C D FM ...

Page 2: ...TABLEOFCONTENTS SECTION PAGE Safety Information 3 General Information 4 Pump Installation 5 Pump Operation Maintenance 6 Troubleshooting 7 Parts List 8 Wiring Diagrams 15 Warranty 16 ...

Page 3: ...ial An improperly sized tank can cause the pump to cycle and lead to pump damage This may require a larger pressure tank than is normally used CALIFORNIA PROPOSITION 65 WARNING This product and related accessories contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm ELECTRICAL SAFETY ELECTROCUTION HAZARD Must be installed by a qualified profes...

Page 4: ...inding temperature the starter in the panel breaks power to the pump Once the sensor resets the starter is automatically reset for FM for continued operation of the pump This circuitry is supplied in a Hydromatic control panel The sensors are set to trip at 130 C Failure to install such circuitry would negate FM approvals and all warranties by Hydromatic POWER CORDS The power cord and heat sensor ...

Page 5: ...nge Pumps shipped from the factory as 460 volt 3 phase cannot be rewired to any other voltage TO RE WIRE THE PUMP FROM 230V TO 460V 3 PHASE Only a 230V pump from the factory is considered dual voltage a cord label clearly states the factory wound voltage 1 Remove all six 7 cap screws then raise the cord cap assembly enough to slip a prying instrument on opposite sides between the cord cap casting ...

Page 6: ...ble motors that are out of warranty can be serviced in the field by any reliable motor service shop Any pump that is in warranty must be returned to the factory for service or repaired at an authorized Pentair Hydromatic service center Charges will not be allowed if in warranty pump is not taken to an authorized Pentair Hydromatic service center When field service is performed on a pump these inst...

Page 7: ...city 1 Discharge gate valve may be partially closed or partially clogged 2 Check valve may be partially clogged Raise level up and down to clear 3 Pump may be running in wrong direction Low speed pumps can operate in reverse direction without much noise or vibration 4 Discharge head may be too high Check total head with gauge when pump is operating Total head is discharge gauge pressure converted ...

Page 8: ...5 CORD CAP ASSEMBLY 4 4 W 1 25 107550312 SEAL PLATE 1 132531001 OIL DIELECTRIC VARIES PUMP PARTS LIST 1 2 3 4 5 7 8 12 11 15 16 18 19 10 A1 A2 A4 24 6 16 16 17 13 14 20 21 A3 22 23 9 20 25 250 FRAME PUMPS Ref Part No Part Description Qty 1 28012D000 MOTOR HOUSING 1 2 27966D010 BEARING HOUSING 1 3 27882A009 TERMINAL BLOCK 1 4 06106A069 SCREW CAP SKT HD 2 5 110650043 SCREEN 1 6 19331A009 WASHER SPRI...

Page 9: ...1 005700181 005700181 005680191 D7 SCREW MACHINE NOT SHOWN SEE VOLUTE ASSY 008290061 3 008290061 3 N A SEE VOLUTE ASSY SEE VOLUTE ASSY 008290091 4 SEE VOLUTE ASSY N A D8 WEAR RING SEE VOLUTE ASSY 136900003 136900003 N A SEE VOLUTE ASSY SEE VOLUTE ASSY 136900003 SEE VOLUTE ASSY N A D9 CUTTER PLATE N A N A N A N A N A N A N A N A 153600002 D10 CUTTER INSERT N A N A N A N A N A N A N A N A 153320014 ...

Page 10: ...A027 A4 SPACER 076650041 076650041 076650041 076650121 076650121 076650121 CONNECTOR 12672A001 12672A001 ITEM 8 POLE 870 RPM 10 15 HP 10 15 HP 10 15 HP 208 230 3 60 460 3 60 575 3 60 A1 STATOR 27963D003 27963D003 27963D603 A2 ROTOR SHAFT ASSEMBLY 27963D011 27963D011 27963D011 A3 BOLT STATOR 4 005560081 005560081 005560081 A4 SPACER 076651001 076651001 076651001 CONNECTOR 12672A001 ITEM 6 POLE 1150...

Page 11: ...8 110430382 S4LV X P4000FC 40 460 3 6 4 11 5 110430012 S4LV X P4000GC 40 575 3 8 4 11 5 110430012 1150 RPM S4LV X P750DB 7 5 208 3 8 4 10 110430042 S4LV X P750EB 7 5 230 3 8 4 10 110430042 S4LV X P750FB 7 5 460 3 10 4 10 110430042 S4LV X P750GB 7 5 575 3 10 4 10 110430042 S4LV X P1000DB 10 208 3 8 4 11 25 110430082 S4LV X P1000EB 10 230 3 8 4 11 25 110430082 S4LV X P1000FB 10 460 3 10 4 11 25 1104...

Page 12: ...025940002 S4L X P750FA 7 5 460 3 10 4 11 88 025940002 S4L X P750GA 7 5 575 3 10 4 11 88 025940002 S6L X P Cat No HP Volt Ph Cord Trim Impeller 1750 RPM S6L X P2000DC 20 208 3 6 4 9 88 025940372 S6L X P2000EC 20 230 3 6 4 9 88 025940372 S6L X P2000FC 20 460 3 8 4 9 88 025940372 S6L X P2000GC 20 575 3 8 4 9 88 025940372 S6L X P2500DC 25 208 3 4 4 10 25 025940072 S6L X P2500EC 25 230 3 6 4 10 25 0259...

Page 13: ... P2500FC 25 460 3 8 4 10 13 025940172 S8F X P2500GC 25 575 3 8 4 10 13 025940172 S8F X P3000EC 30 230 3 4 4 10 5 025940082 S8F X P3000FC 30 460 3 8 4 10 5 025940082 S8F X P3000GC 30 575 3 8 4 10 5 025940082 S8F X P4000FC 40 460 3 6 4 11 38 025940202 S8F X P4000GC 40 575 3 8 4 11 38 025940202 1150 RPM S8F X P750DB 7 5 208 3 8 4 10 38 025940162 S8F X P750EB 7 5 230 3 8 4 10 38 025940162 S8F X P750FB...

Page 14: ...20 460 3 8 4 12 136920012 S4B X P2000GB 20 575 3 10 4 12 136920012 870 RPM S4B X P1000DA 10 208 3 8 4 12 136920012 S4B X P1000EA 10 230 3 8 4 12 136920012 S4B X P1000FA 10 460 3 10 4 12 136920012 S4B X P1000GA 10 575 3 10 4 12 136920012 S4LV X P CAT NO HP VOLT PH CORD TRIM IMPELLER 1750 RPM S4LV X P5000FC 50 460 3 4 4 12 110430002 S4LV X P5000GC 50 575 3 6 4 12 110430002 S6A X P CAT NO HP VOLT PH ...

Page 15: ...15 E 03 558 07 05 20 WIRINGDIAGRAMS ...

Page 16: ...ll dual seal pumps Under no circumstance will Pentair Hydromatic be responsible for the cost of field labor travel expenses rented equipment removal reinstallation costs or freight expenses to and from the factory or an authorized Pentair Hydromatic service facility This limited warranty will not apply a to defects or malfunctions resulting from failure to properly install operate or main tain the...

Reviews: