54
Technical Data – Gas Bottle Crane
Electrical Specification - all models utilise the same type of winch in 12 volt or
24 volt form.
12 volts DC 70A
24 volts DC 35A
110 and 240 volt – Contact Penny Hydraulics Ltd for more information.
Winch Operating Temperature
A range of -
5
°
C to
30
°
C for both 12 Volt and 24 Volt winches.
Winch Duty Cycle
1 minute of continuous running within a 15 minute period for both 12 Volt and
24 Volt winches
Typical Weights
Standard SwingLift crane – 60kg subject to specification including winch unit.
Maximum Working Load
Each GBC is marked individually with its maximum working load.
Noise Levels
A survey sheet giving full details is available on request. Briefly, the results are
as follows:
Winch running 65dB(A)
These levels are well below those at which hearing can be damaged and below
levels at which action is required under the noise at work regulations.
COSHH – Terminal Disposal
Penny Hydraulics will remove and dispose of the entire crane in an
environmentally sound manner when required.