MODEL 7500/4 RS-232 SCALE COMMANDS
General Commands
ATW
Acquire Tare Weight
CHK
Initiate self-diagnostics CHecK
LCK
LoCK out keypad
PON
Power ON
POF
Power OFf
RES
RESet, clears tare weight and piece weight
SCM
Select Count Mode
SSS
Select Sample Size
SWM
Seclect Weight Mode
UCK
UnloCK keypad
UNP
UNit Primary
UNS
UNit Secondary
ZRO
ZeRO scale
Commands Which Enter Information into the Unit
IPW [ FLOATING POINT NUMBER ]
Input Piece Weight
ITW [ FLOATING POINT NUMBER ]
Input Tare Weight
Commands Which Request Information
SAI
Send All Information (All setup information)
SAO
Send Abbreviated Output (Same as SRP)
SCI
Send Configuration Information
SCO
Send COunt
SDT
Send DaTe (Time and Date option only)
SGW
Send Gross Weight
SMI
Send Metrological Information
SNW
Send Net Weight
SPC
Send Print Codes
SPW
Send Piece Weight
SRP
Send Requested Print
SSZ
Send Sample siZe
STM
Send TiMe (Time and Date option only)
STW
Send Tare Weight
SVN
Send Software Version Number