18
Commands Which Request Information
SAI
Send All Information
SAO
Send Abbreviated Output (same as SRP)
SCI
Send Configuration Information
SCO
Send COunt
SDT
Send DaTe (with time and date option only)
SGW
Send Gross Weight
SMI
Send Metrological Information
SNW
Send Net Weight
SPC
Send Print Codes
SPW
Send Piece Weight
SRP
Send Requested Print
SSZ
Send Sample siZe
STM
Send TiMe (with time and date option only)
STW
Send Tare Weight
SVN
Send Software Version Number
Calibrate and Configure Commands
CAL
CALibrate - Same as pressing SW4 button.
CFC
ConFigure Communication - To set baud rate etc.
CFP
ConFigure Print codes - To enter print codes.
CLE
CaLibration End - To save calibration data.
CLP
CaLibrate Primary - To set-up primary calibra-
tion data.
CLS
CaLibrate Secondary - To set-up secondary cali-
bration data.
CLU
CaLibration Unstable - To set-up print
stable/unstable.
CLW
CaLibration Weight - To calibrate with weights.
NOTES:
All commands and parameters must be separated by spaces.
The entire command string must be terminated with a carriage return.
All calibrate and configure commands are further explained in the
"Calibration and Programming Section of this Manual".