background image

Comfort Warm System

The Comfort Warm keypad controls three levels of heat. Pushing the button repeatedly will cycle through the different levels 

of heat with the first push being the hottest and the fourth turning the Comfort Warm off. They will also automatically shut 

off after 30min. 

Heating pads are stuck on with a high strength adhesive. If replacing, disconnect wire connections and peel off pad. Clean 

with an alcohol wipe or non-residue cleaner and peel backing from new pad. Apply from center out of pad and press firmly. 

Reconnect wires. Do not remove white insulation backing. 

Load Center-Spa Control

Load Center-Comfort Warm System

760748 Rev C  10-1-2021

11

1-800-732-0717

www.pennerbathing.com

1-866-736-6377

Load Center 760500

The Load Center is a no repair item. If it has been determined that the load center is at 

fault, replacement of the unit will be necessary. Open the lid, disconnect the air line, 

blower motor supply, Comfort Warm power supply and then use a  3/8” nut driver to take 

off the nuts (350955) to remove the unit. 

1

2

3

4

1. Air Switch air line connection

2. Air Blower Motor Connection #3

3. Comfort Warm Keypad Connection

4. Comfort Warm power supply

1. Keypad 

760560

1. Heating Pad 

760550

2. Cable-Split 

760555    

(Not Shown)

1

1

Summary of Contents for 760010-1

Page 1: ...nd Service Manual 760748 Rev C 10 1 2021 Penner Patient Care 101 Grant St Aurora NE 68818 Service help call 1 800 732 0717 or 1 866 736 6377 www pennerbathing com 1 1 800 732 0717 www pennerbathing co...

Page 2: ...Dream Spa Operational Controls Internal Spa Front View Tempering Valve Adjustment Dream Water Door Internals Dream Water Door External Components Aqua Aire System Drain Components Plumbing Supply Load...

Page 3: ...or Air Switch Hot Temperature Valve Kit Fill Spigot Kit Cold Temperature Valve Kit Tub Fill Temperature Gauge Comm Only Shower Sprayer Temperature Gauge Comm Only Diverter Valve Kit Shower Sprayer Lab...

Page 4: ...400212 Overflow Escutcheon Drain Screen Drain Plug Grab Bar Water Door Assembly Jets Post Safety belt loop Comm Only Rod Safety belt loop Comm Only Safety Belt Fastening Procedure shown below Comm On...

Page 5: ...mpering Valve Adjustment Procedure To adjust the max hot temperature use the provided Allen wrench to remove screw from cap of tempering valve Take cap part way off valve so only inner splines of cap...

Page 6: ...2 Clevis Pin x 1 SS Qty 2 Cotter Pin 3 32 x SS Qty 2 Hinge Hinge Screw Qty 16 Upper Push Bar Torque Arm Vertical Push Link Spring Lower Push Link Lower Pivot Arm Clevis Pin 3 8 x 1 Qty 3 Cotter Pin 5...

Page 7: ...by using a 2 Phillips screwdriver and removing the screws on the spa side hinge leaf 1 2 6 4 Both fascia pieces can be taken off by removing the screws Two 2 screws on the smaller fascia and four 4 on...

Page 8: ...et Replacement Kit Cap Black Jet 1 760406 2 760602 3 590758 4 360603 5 350276 6 360650 7 360655 8 350132 9 350134 10 360644 1 8 7 6 5 4 3 2 3 10 9 Air Jets can be cleaned from hard build up by using a...

Page 9: ...2 Not shown Tee Drain New Plastic Washer 1 7 8 x2 Rubber Base Shoe Basket Chrome Base Shoe Assembly Removal Tool Chrome Basket 1 350174 2 350173 3 590758 4 390410 5 1050481 6 1050501 7 1050461 8 10503...

Page 10: ...for thermometers Washer for adaptor 760540 and shower hose Air Push Button for Blower motor Shower Hose Cold Main Supply line 72 length Hot Main Supply line 72 length 1 760535 2 760540 3 760545 4 7604...

Page 11: ...firmly Reconnect wires Do not remove white insulation backing Load Center Spa Control Load Center Comfort Warm System 760748 Rev C 10 1 2021 11 1 800 732 0717 www pennerbathing com 1 866 736 6377 Load...

Page 12: ...ned to provide in service instruction and maintenance on your Dream Spa System If you have any questions about the operation or maintenance of your Dream Spa please contact your Penner Distributor For...

Reviews: