Table 6: A99 Temperature Sensors selection chart

Product code

1

Description

A99BC-300C

1

PTC Temperature Sensor: Standard probe 2 in.

(5.1 cm) with 9.8 ft (3.0 m) high-temperature

silicon cable; ambient operating temperature

range: -40ºF to 248ºF (-40ºC to 120ºC)

A99BC-500C

1

PTC Temperature Sensor: Standard probe 2 in.

(5.1 cm) with 16.4 ft (5.0 m) high-temperature

silicon cable; ambient operating temperature

range: -40ºF to 248ºF (-40ºC to 120ºC)

A99BC-1500C

1

PTC Temperature Sensor: Standard probe 2 in.

(5.1 cm) with 49.2 ft (15.0 m) high-temperature

silicon cable; ambient operating temperature

range: -40ºF to 248ºF (-40ºC to 120ºC)

A99CB-200C

PTC Temperature Sensor: Extended probe 6 in.

(15.2 cm) with 6.6 ft (2.0 m) PVC cable; ambient

operating temperature range: -40ºF to 212ºF

(-40ºC to 100ºC)

A99CB-600C

PTC Temperature Sensor: Extended probe 6 in.

(15.2 cm) with 19.7 ft (6.0 m) PVC cable; ambient

operating temperature range: -40ºF to 212ºF

(-40ºC to 100ºC)

1

When any A99 Series Temperature Sensor is connected

to a standard A421 Control model, the range of displayed

temperature values is -40ºF to 212ºF or -40ºC to 100ºC.

Table 7: Accessories

Product code Description

BKT287-1R

12 in. (305 mm) long DIN rail section

BKT287-2R

36 in. (914 mm) long DIN rail section

PLT344-1R

Two end clamps for DIN rail sections

A99-CLP-1

Surface mounting clip for A99B and A99C Series

Temperature Sensors

SHL10-603R

Sun shield for A99B and A99C Series

Temperature Sensors

BOX10A-603R PVC enclosure for A99B and A99C Series

Temperature Sensors

WEL11A-601R Copper and brass immersion well for applying

sensor in fluid applications

TE-6300W-102 Stainless steel immersion well for applying

A99 sensors in fluid applications. (A99CB Type

sensors with extended probe are recommended

for use with this immersion well.)

Technical specifications

Table 8: A421 Series Electronic Temperature Controls

Technical Specifications

Specification Description

Power

consumption

1.8 VA maximum

Supply power 110/120 or 208/230/240 VAC, 50/60 Hz

Table 8: A421 Series Electronic Temperature Controls

Technical Specifications

Specification Description

Ambient

conditions

Operating: 

 Type 1 models: -40°F to 150°F (-40°C

to 66°C), 0% to 95% RH noncondensing

Type 4X models: -40°F to 140°F (-40°C to 60°C),

0% to 95% RH noncondensing

Shipping and storage:

 All models: -40°F to 185°F

(-40°C to 85°C), 0% to 95% RH noncondensing

Temperature

control range

-40°F to 212°F or -40°C to 100°C

Input signal

1,035 ohm at 77°F (25°C) for A99 PTC

temperature sensors

Accuracy

Combined accuracy of A421 Control and A99

sensor: ±2°F (±1°C) between 5°F and 167°F(-15°C

and 75°C); diverging to ±3°F (±2°C) at -40°F

(-40°C) and ±3°F (±2°C) at 212°F (100°C)

Sensor offset

range

±5ºF or ±3ºC

Enclosure

material

Type 1, IP20 high-impact thermoplastic or

Type 4X, IP66 watertight, corrosion-resistant,

high-impact thermoplastic

Note

: To maintain type 4X / IP66 rating, tighten

enclosure screws to: 10 – 12 in·lb.

Compliance

North America:

 cULus Listed; UL 60730, File

E27734, Vol. 1; FCC Compliant to CFR47, Part 15,

Subpart B, Class B
Industry Canada (IC) Compliant to Canadian

ICES-003, Class B limits

Europe:

 CE Mark – Johnson Controls declares

that this product is in compliance with the

essential requirements and other relevant

provisions of the EMC Directive; Low Voltage

Directive.

Australia and New Zealand:

 RCM, Australia/NZ

Emissions Compliant

Table 9: A421 Temperature Control Output Relay

Contacts electrical ratings

A421

Agency and file

UL 60730 and EN 60730

Applied AC voltage at

50/60 Hz

120 VAC

208 VAC

240 VAC

Horsepower LC/LNO

(LC/LNC)

1 (0.25)

1 (0.3)

1 (0.5)

Full load amperes LC/

LNO (LC/LNC)

16 (5.8)

9.2 (4)

8 (4.9)

Locked rotor amperes

LC/LNO (LC/LNC)

96 (34.8)

55.2 (24)

48 (29.4)

Resistive amperes LC/

LNO (LC/LNC)

15 (10)

10 (10)

10 (10)

Pilot duty VA LC/LNO

(LC/LNC)

125 (125)

125 (125)

125 (125)

Table 10: UL conformity declaration information

Information

Description

Purpose of control

Sensing control / Operating control

A421 Series Electronic Temperature Controls with Cycle Timer Installation Guide

12

Summary of Contents for A421 Series

Page 1: ...ou de protection en cas de d faillance ou de dysfonctionnement du A421 Control The A421 Series Electronic Temperature Controls are single stage electronic temperature controls with a single pole doubl...

Page 2: ...range of usable values from 40 F to 212 F or 40 C to 100 C See Wiring Technical specifications and refer to the A99B Series Temperature Sensors Product Technical Bulletin LIT 125186 for more informat...

Page 3: ...l ratings Exceeding the electrical ratings can result in permanent damage to the control and void any warranty Important Run all low voltage wiring and cables separate from all high voltage wiring It...

Page 4: ...re for 120 VAC supply power applications Connect the L1 supply power lead for all 208 240 VAC supply power applications 120V Line voltage 120 VAC control power hot Connect the 120 VAC supply power hot...

Page 5: ...On temperature On Select the temperature at which the output relay energizes the LC to LNO relay contacts close cut in and the green LED lights The range of usable temperature values is 40 F to 212 F...

Page 6: ...brightest backlight setting and the system default The selected backlight brightness level is applied to the LCD during normal operation When you enter the programming menus to set up the control or p...

Page 7: ...ave a new value the control reverts to the last saved value After 30 seconds of inactivity while in any screen the control reverts to the Main screen Basic menu Use the Basic menu to quickly edit the...

Page 8: ...tween the On and OFF values the following behavior is enforced The fan relay is On for at least the Minimum Relay On Time Ont during a Cycle Period cP See Figure 8 The fan relay goes Off when the sens...

Page 9: ...Restricted mode prevents casual users from over adjusting the control in your application or from inadvertently changing the mode of operation from cooling to heating or heating to cooling by over adj...

Page 10: ...e See Troubleshooting procedure Cycle power to reset the control SF flashing alternately with SH Shorted temperature sensor or sensor wiring Output functions according to the selected SF mode See Trou...

Page 11: ...with Cycle Timer Type 1 NEMA IP20 standard enclosure for DIN rail and surface mount applications Rated for 120 240 VAC Includes timer for On Off duty cycle control Includes an A99BB 200C temperature s...

Page 12: ...Specification Description Power consumption 1 8 VA maximum Supply power 110 120 or 208 230 240 VAC 50 60 Hz Table 8 A421 Series Electronic Temperature Controls Technical Specifications Specification...

Page 13: ...00 RH condensing Shipping weight 1 4 oz 41 g for 6 1 2 ft 2 m sensor Accessories See Table 7 1 When any A99 Series Temperature Sensor is connected to a standard A421 Control model the range of display...

Page 14: ...SON CONTROLS WESTENDHOF 3 45143 ESSEN GERMANY JOHNSON CONTROLS 507 E MICHIGAN ST MILWAUKEE WI 53202 USA For more contact information refer to www johnsoncontrols com locations 2019 Johnson Controls Al...

Reviews: