5.2 - Set-Up, Operating, & Take-Down Procedures

Prior to Operation, the #6759 Work Umbrella should be configured and prepared according to the following guidelines.

 It is necessary to perform a visual inspection, each time, prior to using the product. If deficiencies are found, remove the 

product from service and contact the T.A. Pelsue Company regarding repair.  The following checklist coupled with 

Figure 

#5.2a

 should be used as a guide to determine whether the equipment is in good operating condition prior to usage. 

Equipment that is not in good condition can endanger the safety of the entrant(s) and attendant(s) during use.  

The Pre-Operation Visual Inspection is not limited to, but must include the following items;

a.  

 Suction cup rubber base must be clean, free of debris, not cut or torn, and the round, white air filter must be in 

place. If these conditions are not met, positive hold will be diminished or impossible.

b.  

 Check rod & handle pockets (corners of the roof have reinforced nylon and webbing) for signs of wear or loose 

seams. These pockets are critical to tent tension and must be intact. Observe rod pocket locations in 

Fig. 5.2a.

 

c.

  Two rubber straps connecting the suction cups to the fiberglass rod must be free of cracks or tears.

Set-Up of #6759 Work Umbrella with Vacuum Mount Suction Cups

Choose a location where installation will provide suitable protection to the work area, yet minimize obstructions during use. 

The suction cups require a smooth, clean surface (flat is not necessary). Mud, grease, or any form of grime must be wiped 

off before installation to ensure positive hold. Suction cups hold well on wet or dry surfaces. Once a location is chosen:

a.   

Remove the Umbrella and support structure from the carry bag. The system consists of one complete assembly for 

the attachment interface and support structure, as well as a complete sewn assembly with integral tent rods and 

ball-hub.    

b.

   To start, determine the placement of the suction cups, abiding the notes about the surface condition listed above. 

Place the cups firmly against the desired mount location, and pump the white plunger shaft repeatedly until the red 

line is no longer visible. This red line is an indicator that the vacuum seal has diminished; to remedy, simply press 

the plunger again. Once the red line on the plunger is no longer visible, the cup is optimally secured.

c.

  Repeat with the other suction cup. 

d.

   Loosen the handle on the toothed hinge by turning it counter-clockwise. This will allow the hinge to spin 360 

degrees, so use caution that the assembly does not rotate and strike the operator or others present. The shaft has 

been fixed so as to only allow a maximum gap of about 1/4”; do not attempt to force the hinge open any further. 

Place the upper section of the assembly where appropriate, then tighten the handle fully, engaging the teeth com-

pletely. 

e.

   The other hinge operates on a push button. This hinge has 220 degrees of travel. Use this hinge to orient the 

uppermost rod at the final angle desired (roughly vertical is recommended). 

f.

   Now the sewn assembly can be attached. With the black surface facing the operator, grab the rod which is attached 

at only one end - taking caution to avoid the hub to avoid injury - then pull out and down on the red handle while 

pushing up on the rod. Slip the end of the loose rod into the pocket of the red handle.  

g.

  Finally, place the hub of the Umbrella onto the white ball at the top of the assembly; spin the collar onto the hub. 

h.

  The ball hub is designed to auto-level the roof, but it can be adjusted to tilt manually. Once the orientation is as                 

      desired, hand-tighten the collar to secure the Umbrella to the structure. 

 

Important Notes: 

-  The positive hold of the cups must be main-

tained  throughout  operation.  Periodically 

check the red line indicator for vacuum, and 

press the plunger as necessary to maintain. 

Different  surfaces  and  surface  conditions 

will determine the frequency required. 

-  The handles on the cup mounting brackets 

may be loosened to rotate the entire support 

structure.  Ensure  that  they  are  tightened 

before operation to avoid unwanted move-

ment of the tent. 

ROD 

POCkET

LOCATION

ROD 

POCkET

LOCATIONS

Figure #5.2a:

 #6759 Roof,

Support Structure Omitted for Clarity

HANDLE

POCkET

LOCATION

Summary of Contents for 6759

Page 1: ...ct Manual Model 6759 Work Umbrella T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Tel 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ISO 9001 Certified ...

Page 2: ... 950130 001 Product Manual Model 6759 WORK UMBRELLA Revision 00 Date 09 06 2016 Page 2 ...

Page 3: ...nuing reputation for excellence in the production of fine products for a broad spectrum of industry throughout the world Now in our second generation of family direction continued commitment to innovation and quality makes Pelsue a leading source of equipment for many types of confined spaces We specialize in safety retrieval fall arrest ventilation cable placing splicing and maintenance nationall...

Page 4: ... Information 5 1 1 Quality Policy 1 2 Pelsue Product Warranty 2 0 Introduction Product Information 7 2 1 Serial Number 3 0 Configuration Assembly 8 3 1 Parts Diagram List 4 0 Safety 10 4 1 Safety Alert Symbol 4 2 General Safety Information 5 0 Product Operation 12 5 1 Product Description Capabilities 5 2 Set Up Operating Take Down Procedures ...

Page 5: ...sfaction is one of the differentiators that sets you apart from the pack and yields a competitive advantage Therefore we will support total customer satisfaction by implementing the ISO 9001 Quality System and providing the necessary atmosphere and training to nurture this concept throughout our organization We will make every business decisionas though the quality of the part or service provided ...

Page 6: ...IHFWLYH FRPSRQHQWV DQG VKLS ZLWKLQ GD V RI UHFHLSW RI GHIHFWLYH FRPSRQHQW 7KH UHSDLUHG RU UHSODFHG FRPSRQHQW ZLOO EH UHWXUQHG WR FXVWRPHU IUHLJKW SUHSDLG E 7 3HOVXH RPSDQ I PDWHULDO UHWXUQHG WR 7 3HOVXH RPSDQ IRU UHSDLU DV SURYLGHG IRU LQ WKLV VHFWLRQ LV GHWHUPLQHG WR EH EH RQG UHSDLU WKH 7 3HOVXH RPSDQ VKDOO QRWLI WKH VHQGHU DQG XQOHVV RWKHUZLVH DJUHHG ZLOO VKLS D UHSODFHPHQW XQLW ZLWKLQ GD V RI ...

Page 7: ...ice or other information The identifying decal is permanently embossed with a serial number The ID decal is located in the corner of the inner side of the roof as shown in Fig 2a The entire support structure has been omitted from Fig 2a for clarity The decal will appear as shown to the right in Fig 2b A space has been provided below for the recording of the serial number for future reference Figur...

Page 8: ...age If damage to any of the components is discovered Alert the shipping carrier immediately of the damage to the shipment Refer to the following parts breakdown diagram Figure 3 1a and the accompanying parts list Table 3 1a for iden tification of parts in the event replacements become necessary The parts list table displays applicable part numbers descriptions and quantity per assembly Replacement...

Page 9: ... NUT HEx 1 4 20 UNC PLATED 4 18 126729 001 SCREW TAP HEx HD 1 4 20 x 3 L ALLTHREAD S STEEL 1 19 100216 002 ROD END TENT HUB RES 6 375 ID zINC 4 20 104029 001 ROD F GLASS 375 DIA x 41 5 CHAMFERED ONE VINYL TIP 4 21 126552 001 HINGE LOCkING PLASTIC 220 ROTATION 5 8 HOLES 1 22 106503 000 HOSE RUBBER 5 8 ID HEATER HOSE BLACk 1 23 118864 001 VACUUM MOUNT SUCTION CUP 4 5 DIA 1 4 20 INSERT 2 24 100121 00...

Page 10: ...e 6759 Umbrella and alert you to good safety and operating practices while using the system Remember you are the key to safety Good safety practices not only protect you but also the people around you Make these practices a working part of your safety program Be certain that everyone operating in or around a confined space is familiar with the procedures recommended and follows safety precautions ...

Page 11: ...e product The Safety Precautions are not limited to but must include the following items 1 Do not use the shelter for anything other than its intended use 2 Loose fabric may become caught in rotating machinery if operating a ventilator heater blower or any other equip ment with spinning parts be sure that adequate clearance is given between the Umbrella and rotating equipment especially during set...

Page 12: ...ll lock The roof is made of shade material which is white on the outside and black on the inside This allows the Umbrella to provide ultra violet protection without blacking out all light Computer screens which could not be read in direct sunlight are easily visible in the shade of the Umbrella There is no need for an additional light source during daylight hours The shade material also reduces so...

Page 13: ...s about the surface condition listed above Place the cups firmly against the desired mount location and pump the white plunger shaft repeatedly until the red line is no longer visible This red line is an indicator that the vacuum seal has diminished to remedy simply press the plunger again Once the red line on the plunger is no longer visible the cup is optimally secured c Repeat with the other su...

Page 14: ...trike the operator or others present The shaft has been fixed so as to only allow a maximum gap of about 1 4 do not attempt to force the hinge open any further Position the upper section of fiberglass rod to be aligned with the section for the suction cups Then tighten the handle fully engaging the teeth completely Leaving the hinge in an open position during storage could lead to bending of the s...

Page 15: ...Notes ...

Page 16: ...ISO 9001 Certified T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Toll free 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ...

Reviews: