#950130-001 -
Product Manual: Model #6759 WORK UMBRELLA
- Revision 00 - Date: 09-06-2016
Page 13
5.2 - Set-Up, Operating, & Take-Down Procedures
Prior to Operation, the #6759 Work Umbrella should be configured and prepared according to the following guidelines.
It is necessary to perform a visual inspection, each time, prior to using the product. If deficiencies are found, remove the
product from service and contact the T.A. Pelsue Company regarding repair. The following checklist coupled with
Figure
#5.2a
should be used as a guide to determine whether the equipment is in good operating condition prior to usage.
Equipment that is not in good condition can endanger the safety of the entrant(s) and attendant(s) during use.
The Pre-Operation Visual Inspection is not limited to, but must include the following items;
a.
Suction cup rubber base must be clean, free of debris, not cut or torn, and the round, white air filter must be in
place. If these conditions are not met, positive hold will be diminished or impossible.
b.
Check rod & handle pockets (corners of the roof have reinforced nylon and webbing) for signs of wear or loose
seams. These pockets are critical to tent tension and must be intact. Observe rod pocket locations in
Fig. 5.2a.
c.
Two rubber straps connecting the suction cups to the fiberglass rod must be free of cracks or tears.
Set-Up of #6759 Work Umbrella with Vacuum Mount Suction Cups
Choose a location where installation will provide suitable protection to the work area, yet minimize obstructions during use.
The suction cups require a smooth, clean surface (flat is not necessary). Mud, grease, or any form of grime must be wiped
off before installation to ensure positive hold. Suction cups hold well on wet or dry surfaces. Once a location is chosen:
a.
Remove the Umbrella and support structure from the carry bag. The system consists of one complete assembly for
the attachment interface and support structure, as well as a complete sewn assembly with integral tent rods and
ball-hub.
b.
To start, determine the placement of the suction cups, abiding the notes about the surface condition listed above.
Place the cups firmly against the desired mount location, and pump the white plunger shaft repeatedly until the red
line is no longer visible. This red line is an indicator that the vacuum seal has diminished; to remedy, simply press
the plunger again. Once the red line on the plunger is no longer visible, the cup is optimally secured.
c.
Repeat with the other suction cup.
d.
Loosen the handle on the toothed hinge by turning it counter-clockwise. This will allow the hinge to spin 360
degrees, so use caution that the assembly does not rotate and strike the operator or others present. The shaft has
been fixed so as to only allow a maximum gap of about 1/4”; do not attempt to force the hinge open any further.
Place the upper section of the assembly where appropriate, then tighten the handle fully, engaging the teeth com-
pletely.
e.
The other hinge operates on a push button. This hinge has 220 degrees of travel. Use this hinge to orient the
uppermost rod at the final angle desired (roughly vertical is recommended).
f.
Now the sewn assembly can be attached. With the black surface facing the operator, grab the rod which is attached
at only one end - taking caution to avoid the hub to avoid injury - then pull out and down on the red handle while
pushing up on the rod. Slip the end of the loose rod into the pocket of the red handle.
g.
Finally, place the hub of the Umbrella onto the white ball at the top of the assembly; spin the collar onto the hub.
h.
The ball hub is designed to auto-level the roof, but it can be adjusted to tilt manually. Once the orientation is as
desired, hand-tighten the collar to secure the Umbrella to the structure.
Important Notes:
- The positive hold of the cups must be main-
tained throughout operation. Periodically
check the red line indicator for vacuum, and
press the plunger as necessary to maintain.
Different surfaces and surface conditions
will determine the frequency required.
- The handles on the cup mounting brackets
may be loosened to rotate the entire support
structure. Ensure that they are tightened
before operation to avoid unwanted move-
ment of the tent.
ROD
LOCATION
ROD
LOCATIONS
Figure #5.2a:
#6759 Roof,
Support Structure Omitted for Clarity
HANDLE
LOCATION