Pelsue 1325D Product Manual Download Page 11

Page 11

#109998-001 - Product Manual - #1325D Axial Ventialtor

 - Revision 07 - Date: 07-13-2016

The following section will address the safety precautions which must be adhered to when working with Pelsue confined 

Space Ventilation equipment such as the #1325D Axial Ventilator.  Any user must familiarize themselves with the infor-
mation in this section before utilizing the equipment.

SIGNAL WORDS:

Note the use of the signal words 

DANGer

WArNING

 and 

CAutION

 with the safety messages. The appropriate signal 

word for each message has been selected using the following guidelines:

D

ANGer- 

Indicates an imminently hazardous situation that, if not avoided, will result in death or serious injury. This 

signal word is to be limited to the most extreme situations or for hidden or unseen hazards.

WArNING-

  Indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury and 

includes obvious and hidden hazards. It may also be used to alert against unsafe practices.

CAutION-

  Indicates a potentially hazardous situation that, if not avoided, may result in minor or moderate injury. It 

may also be used to alert against unsafe practices.

You are responsible for the safe operation of your Pelsue #1325D Axial Ventilator. You must ensure that anyone who 

will operate or work around the equipment be familiar with confined space ventilation procedures. This manual will take 

you step-by-step through the workings and capabilities of the #1325D Axial Ventilator and alert you to all good safety 

and operating practices while using the system.
Remember, you are the key to safety. Good safety practices not only protect you but also the people around you. Make 

these practices a working part of your safety program. Be certain that everyone operating in or around a confined space 

is familiar with the procedures recommended and follows safety precautions. Remember, most accidents can be pre-

vented. Do not risk injury or death by ignoring good safety practices.

• 

The most important safety device on this equipment is a safe operator. It is the operator’s responsibility to read 

and understand all safety and operating instructions in the manual and to follow these. Most accidents can be 

avoided.

• 

A person must understand the operation of this equipment and be trained in it’s usage before operating the 

equipment.  An untrained operator exposes himself and others to possible serious  injury or death.

• 

Do not modify the equipment in any way. Unauthorized modification may impair the function and/or safety and 

could affect the life of the equipment.

• 

Think SAFETY! Work SAFELY! 

4.0 - Safety

4.1 - Safety Alert Symbol

SAFETY ALERT SYMBOL

This Safety Alert symbol means 

AtteNtION! BeCOMe Alert! yOur SAFety 

IS INVOlVeD!

The Safety Alert symbol identifies important safety messages on your Pelsue Con

-

fined Space Product and in the manual. When you see this symbol, be alert to the 

possibility of personal injury or death. Follow the instruction in the safety message.

Why is this symbol important to you?

3 BIG Reasons: 

Accidents Disable and Kill.

 

Accidents Cost You Money.

 

Accidents Can Be Avoided.

!

Summary of Contents for 1325D

Page 1: ... Manual Model 1325D Axial Ventilator T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Tel 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ISO 9001 Certified ...

Page 2: ...Page 2 109998 001 Product Manual 1325D Axial Ventialtor Revision 07 Date 07 13 2016 ...

Page 3: ...uing reputation for excellence in the production of fine products for a broad spectrum of industry throughout the world Now in our second generation of family direction continued commitment to innovation and quality makes Pelsue a leading source of equipment for many types of confined spaces We specialize in safety retrieval fall arrest ventilation cable placing splicing and maintenance nationally...

Page 4: ...ation 5 1 1 Quality Policy 1 2 Pelsue Product Warranty 2 0 Introduction Product Information 7 2 1 Serial Number 3 0 Configuration Assembly 8 3 1 Parts Diagram List 3 2 Wiring Diagram 4 0 Safety 11 4 1 Safety Alert Symbol 4 2 General Safety Information 5 0 Product Operation 13 5 1 Product Description Capabilities 5 2 Start Up Operating Procedures ...

Page 5: ...faction is one of the differentiators that sets you apart from the pack and yields a competitive advantage Therefore we will support total customer satisfaction by implementing the ISO 9001 Quality System and providing the necessary atmosphere and training to nurture this concept throughout our organization We will make every business decisionas though the quality of the part or service provided w...

Page 6: ...hall be limited to the repair or replacement of the product or component as set forth above and shall not include any liability whatsoever for damages caused by such failure including but not limited to consequential or incidental dam ages flowing from use or lack of use of product Any replacement repair modification installation or other service performed by the T A Pelsue Company shall be warran...

Page 7: ... Pelsue Model 1325D Axial Ventilator to compliment your confined space ven tilation operation This equipment has been designed and manufactured to exceed confined space requirements and regulations in order to meet the needs of the discriminating operator for efficiency and safety during confined space entry operations Safe efficient and trouble free operation and maintenance of the system require...

Page 8: ...OWER HOUSINGS 1 10 110002 010 ASSEMBLY AxIAL MOTOR 120V 60Hz 1Ph 1 3Hp W CAPACITOR 3 8 SHAFT 1 11 126038 001 END PLATE AxIAL MOTOR AFT OUTLET END MOTOR SUPPORT 1 12 110000 001 GRILLE OUTLET 1300D 1400D AS POWDER COATED IN BLACk 1 13 126038 002 VERTICAL RIB AxIAL MOTOR STEEL HOUSING HANDLE LOCATION ATTACHMENT 1 14 124331 001 HANDLE OVER MOLDED VINYL HANDLE W RIVET ON ENDS 1 15 68N 004300 WASHER LOC...

Page 9: ...Axial Ventialtor Revision 07 Date 07 13 2016 3 1 Parts Diagram List continued Figure 3 1a 1325D Parts Diagram 17 21 8 9 20 19 10 11 10 12 13 19 20 21 22 22 18 3 26 27 7 18 18 6 21 14 5 22 15 16 Figure 3 1b 110002 010 Parts Diagram 5 4 3 6 7 ...

Page 10: ...7 Date 07 13 2016 MOTOR 1 3 HP 120 VAC 60 HZ BUTT SPLICE 14 16 3X CAPACITOR 7 5 MFD 370 VAC 60 HZ PLUG 120 VAC 60 HZ BN BN BK WT BK WT GN GN Figure 3 2a 1325D Wiring Diagram 3 2 Wiring Diagram Shown below in Figure 3 2a is a wiring diagram of the motor and the cordset ...

Page 11: ...of the 1325D Axial Ventilator and alert you to all good safety and operating practices while using the system Remember you are the key to safety Good safety practices not only protect you but also the people around you Make these practices a working part of your safety program Be certain that everyone operating in or around a confined space is familiar with the procedures recommended and follows s...

Page 12: ... 2 Do not wear loose clothing that can become entangled in operating machinery Do not operate the Ventilator without inlet or outlet screen guards in place Do not place fingers or any other object through inlet or outlet screens 3 Always operate the Ventilator from a properly grounded ground fault circuit interrupter equipped receptacle 4 Never handle energized power cords with wet hands 5 Never l...

Page 13: ...t 19 5 LBS Height 14 1 2 Width 13 Length 14 1 2 Model Specifications Performance 1325D Voltage 120VAC 60Hz Amperage 4 H P 1 3 248kW Free Air 1004 CFM 28 4 m3 min One 90º Bend 568 CFM 16 6 m3 min Two 90º Bends 555 CFM 15 7 m3 min 5 1 Product Description Capabilities The following section will address the capabilities and the general operation of the Pelsue 1325D Axial Ventilator The instructions co...

Page 14: ...sed as a guide to determine whether the equipment is in good operating condition prior to usage Equipment that is not in good condition can endanger the safety of the entrant and attendant during use The Pre Operation Visual Inspection is not limited to but must include the following items a Check the Ventilator inlet and outlet guard screens for obstructions b Remove any objects around the immedi...

Page 15: ... cord in the d space between the housing and base or in the outlet port of the Ventilator Important Notes During confined space entry operations it should not be assumed that the ventilator will maintain the air inside the confined space at a safe condition When the ventilator is in use the air inside the confined space should be monitored continuously for the presence of poisonous gases and or to...

Page 16: ...ISO 9001 Certified T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Toll free 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ...

Reviews: